At the intended camera position, cut a circular hole with a
diameter of exactly 70 mm
into the ceiling panel using a suitable tool (e.g. a drilling
machine with hole saw or a drywall utility saw).
When using an electrically powered jigsaw or a hand saw, you should first draw a circle line with a
radius of 35 mm
around the center point to
ensure the specified diameter and roundness of the installation hole.
If necessary, use the drilling template provided.
A-❶
Ø 70 mm
The drilling/cutting entry point should
always be on the later visible side of the
ceiling panel.
Panel thickness
t
= 9 – 18 mm