background image

DF5200HD-IR-ANPR

40

 www.dallmeier.com 

13 

Presets and Mounting

Observe the relation between exposure preset/variant and installation 

heights/distances for the operation of the camera with SEDOR® ANPR 

Server.

Preset for 

variant 401

(3 – 8 m)

Camera

installation 

height (CMH)

Minimum 

distance

(minD)

Capture width 

at minD

(minW)

Maximum 

distance

(maxD)

Capture width 

at maxD

(maxW)

ANPR:3-6m

0.8 – 1.5 m

2 m

2.2 m

6 m

2.5 m

ANPR:4-7m

1 – 2 m

2.5 m

1.8 m

7 m

4 m

ANPR:5-8m

1 – 2 m

3 m

2.2 m

8 m

5 m

Preset for 

variant 402

(6 – 12 m)

Camera

installation 

height (CMH)

Minimum 

distance

(minD)

Capture width 

at minD

(minW)

Maximum 

distance

(maxD)

Capture width 

at maxD

(maxW)

ANPR:6-10m

1 – 2.5 m

6 m

2 m

10 m

3.5 m

ANPR:7-11m

1 – 3 m

7 m

3 m

11 m

4 m

ANPR:8-12m

1 – 3 m

8 m

3 m

12 m

4.5 m

Preset for 

variant 403

(10 – 18 m)

Camera

installation 

height (CMH)

Minimum 

distance

(minD)

Capture width 

at minD

(minW)

Maximum 

distance

(maxD)

Capture width 

at maxD

(maxW)

ANPR:10-14m 1 – 4 m

10 m

3 m

14 m

3 m

ANPR:12-16m 1 – 5 m

12 m

3.5 m

16 m

4 m

ANPR:14-18m 1 – 6 m

14 m

4 m

18 m

4.5 m

The above-mentioned specifications apply to number plates with a 

character height of 7.5 cm. For smaller characters, a reduction of the 

specified distances may be required.

Summary of Contents for DF5200HD-IR-ANPR

Page 1: ...005748 1 0 5 2018 12 17 DF5200HD IR ANPR Commissioning English...

Page 2: ...egistered trademarks of the following owners Google and Google Chrome of Google Inc headquartered in Mountain View California USA JavaScript of Oracle Corporation and or its affiliates headquartered i...

Page 3: ...1 1 1 1 1 1 4 4 4 1...

Page 4: ......

Page 5: ...ortation and Packaging 14 Warranty 14 Appropriate Use 14 Approvals Certifications 16 6 Requirements 17 Ambient Conditions 17 Power Supply 18 7 Maintenance 19 8 Installation and Commissioning 20 9 Fron...

Page 6: ...of delivery in a printed form and or on a digital medium Read all documents included in the scope of delivery carefully and thor oughly before using the device Always follow the contained instructions...

Page 7: ...target audience of this document is trained system integrators Other Applicable Documents Data Sheet The document Data Sheet contains detailed technical specifications features and characteristics of...

Page 8: ...dicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury C...

Page 9: ...ndicated by arrows Always carry out instructions one after the other in the sequence described Expressions in quotation marks generally indicate a control element on the device switches or labels or o...

Page 10: ...ances must be followed Regulations The use of video and audio surveillance systems is in general strictly regulated Inform yourself about the currently valid laws and regulations regarding data worker...

Page 11: ...p to 8 hours until the device has reached room temperature before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact volt ages and devices prot...

Page 12: ...notice burnt smell or a formation of smoke coming from the device immediately disconnect it from the power supply pull out the power plug Contact the sales partner responsible for your area Opening T...

Page 13: ...hole diameter 6mm min drill hole depth 40mm anchor length 30mm 1 Hexagon socket head cap screw fully threaded DIN 912 ISO 4762 M8 12 for hex key size 6mm 1 Hex key size 6mm 1 E DAT modul Cat 6A 8 8 ja...

Page 14: ...recognition of vehicle number plates on a SEDOR ANPR Server appli ance Equipped with the most advanced sensor and encoder technology a powerful IR illumination and a special optical filter the camera...

Page 15: ...storing the video stream in case of a network failure When the network is restored the SmartBackfill function ensures a fast transmission to the SMAVIA recording system This stores the video stream w...

Page 16: ...pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a commercial environment This equipment...

Page 17: ...t install operate the device in places with a large amount of dust and dirt with steam or oil vapors e g kitchen with direct sunlight with strong heat emissions e g radiator with improper ambient temp...

Page 18: ...r the immunity of information and communication technology equipment to elec tromagnetic interferences EMI all protective measures which are specified by the currently valid DIN VDE and ISO standards...

Page 19: ...ce Clean the housing outside with a soft dry and antistatic cloth Do not use detergents Do not use microfiber cleaning cloths Clean the acrylic front glass with water and some dishwashing agent using...

Page 20: ...ews suitable for your wall material Always use the correct type of anchor for your wall type Plastic screw anchors for solid wall material concrete brick Toggle bolt style anchors for drywall hollow w...

Page 21: ...PR www dallmeier com 21 Remove the paper backing from the self adhesive gasket Adhere the gasket to the back of the outdoor wall mount bracket while ensuring that the gasket is aligned as illustrated...

Page 22: ...DF5200HD IR ANPR 22 www dallmeier com Attach the Anti IR reflection hood black to the sunshield as illus trated in Fig 2 and Fig 3 Fig 2...

Page 23: ...reflection hood helps to prevent unwanted reflections from the built in IR LEDs Without the use of the Anti IR reflection hood some IR stray light could be reflected back from the inside finish of the...

Page 24: ...lmeier com Fig 4 A Pre assembled Cat 5e S UTP patch cable terminated with RJ45 8P8C modular plug male connector B Hexagon socket head cap screw fully threaded DIN 912 ISO 4762 M8 12 for hex key size 6...

Page 25: ...the pre assembled RJ45 patch cable A through the outdoor wall mount bracket Assemble the camera housing to the outdoor wall mount bracket as illustrated in Fig 4 and Fig 5 Tighten the hexagon socket h...

Page 26: ...here are different ways to connect the camera to your network You can directly connect the camera to an RJ45 wall socket You can use the delivered Cat 5e RJ45 inline coupler STP Fig 6 and Fig 8 if you...

Page 27: ...T568A Fig 7 you have to wrap the cable connector transitions with a self amalgamating tape to avoid damage to the RJ45 plugs jacks caused by moisture dust and dirt For an optimum protection against m...

Page 28: ...4 Chipboard screw 5 40mm partly threaded pan head 6 lobe drive Torx T25 B 4 Plain washer VA DIN 9021 ISO 7093 inner diameter 5 3mm C 4 Expansion nylon plug S6 drill hole diameter 6mm min drill hole de...

Page 29: ...adhered to the outdoor wall mount bracket as illustrated in Fig 1 Protect the device from direct influence of weather conditions rainfall direct sunlight etc Always use a protected installation site f...

Page 30: ...er Connection and Login on page 34 Log in to the camera see section Login on page 36 Open the Lens control dialog of the camera Align the camera with your scene loosen the respective hexagon socket he...

Page 31: ...DF5200HD IR ANPR www dallmeier com 31 Fig 12 Detailed descriptions of the camera configuration can be found in separate documentations that are available on www dallmeier com...

Page 32: ...ww dallmeier com 9 Front View of Camera A Motor driven P Iris megapixel varifocal lens B Semi covert 850nm high power LEDs for homogeneous IR illumination C Ambient light sensor D Integrated microphon...

Page 33: ...ire Color Code for Pre assembled Patch Cable Fig 14 Pre assembled Cat 5e S UTP patch cable terminated with RJ45 8P8C modular plug male connector Pin No Pair Color 1 2 Red 2 2 Orange 3 3 Black 4 1 Blue...

Page 34: ...njector required System Requirements To configure the device the client PC must meet the following system requirements System Requirements Operating system OS Microsoft Windows 7 10 each with latest s...

Page 35: ...etwork administra tor for more information and assistance Start the web browser Enter the IP address of the device into the address bar of the web browser Confirm the input The connection to the devic...

Page 36: ...thorized users Change the default login credentials of the administrator account as soon as possible Enter your login credentials Confirm with OK After the successful login the graphical user interfac...

Page 37: ...DF5200HD IR ANPR www dallmeier com 37...

Page 38: ...with RJ45 8P8C modular plug male connector 10BASE T 100BASE TX 1000BASE T PoE IEEE 802 3af IR Illumination Type Semi covert 850nm high power LEDs Range Up to approx 18m Miscellaneous Ambient light se...

Page 39: ...le installation sites Indoor and outdoor Operating temperature 40 C to 50 C 40 F to 122 F minimum start up temperature 30 C 22 F Relative humidity 0 90 RH non condensing Approvals Certifications Type...

Page 40: ...t 402 6 12 m Camera installation height CMH Minimum distance minD Capture width at minD minW Maximum distance maxD Capture width at maxD maxW ANPR 6 10m 1 2 5 m 6 m 2 m 10 m 3 5 m ANPR 7 11m 1 3 m 7 m...

Page 41: ...r the positioning of the camera relative to the vehicle number plate Position Vertical angle Max 30 Horizontal angle Max 30 Lateral tilt Max 15 Use the preview of the configuration interface for contr...

Page 42: ...DF5200HD IR ANPR 42 www dallmeier com 14 Dimensions 362mm 14 25 229mm 9 02 88 mm 3 46 225 mm 8 86 136 mm 5 35 233mm 9 17 71mm 2 80 99mm 3 90...

Page 43: ......

Page 44: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 0 941 87 00 0 Fax 49 0 941 87 00 180 www dallmeier com info dallmeier com...

Reviews: