background image

26

 

© 2018 Dallmeier | www.dallmeier.com 

DDF51(X)0HDV-DN-IM Commissioning

 

Screw an M6 eye bolt onto the bottom side of the housing.

M6 eye bolt

Cat.5e RJ45 adapter cable

Ceiling clamp (2×)

Summary of Contents for DDF51 0HDV-DN Series

Page 1: ...006830 1 0 2 2018 12 19 IM DDF51 X 0HDV DN Commissioning English ...

Page 2: ...alifornia USA JavaScript of Oracle Corporation and or its affiliates headquartered in Redwood Shores California USA microSDXC of SD 3C LLC headquartered in North Hollywood California USA Microsoft Internet Explorer Microsoft Edge and Windows of Microsoft Corporation headquartered in Redmond Washington USA Mozilla and Firefox of Mozilla Foundation headquartered in Mountain View California USA Torx ...

Page 3: ...cope of Delivery 12 Transportation and Packaging 12 Warranty 13 Appropriate Use 13 Operation 14 Approvals Certifications 15 6 Requirements 16 Ambient Conditions 16 Power Supply 17 7 Maintenance 20 8 Installation and Commissioning 22 9 Interfaces 40 10 Inserting a Memory Card 42 11 Pin Assignment Interface Board Series 5100 44 12 Connection and Login 49 Connection 50 Login 51 13 Technical Specifica...

Page 4: ...e included in the scope of delivery in a printed form and or on a digital medium Additional information if available is provided exclusively on the website www dallmeier com Read the complete product documentation for the device carefully and thoroughly before using the device Always follow the instructions notes and warnings and observe the technical specifications in the currently valid product ...

Page 5: ...urity surveillance systems installation contractors Other Applicable Documents Data Sheet The product data sheet contains detailed technical specifications features and characteristics of the device The target audience of the document is trained system integrators video security surveillance systems installation contractors Configuration The document entitled Configuration contains detailed inform...

Page 6: ...tion which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE addresses practices not related to physical injury such as device and or property damage due to faulty...

Page 7: ...ry out instructions one after the other in the sequence described Expressions in quotation marks usually refer to individual components of the device housing parts mounting elements connections interfaces etc or to control elements of the device s web based graphical user interface menu items buttons etc Paragraphs in italics provide information on basic principles special features and efficient p...

Page 8: ...tions of the DIN VDE 0701 0702 series of standards VDE 0701 0702 Inspection after repair modification of electrical appliances Periodic inspection on electrical appliances General requirements for electrical safety Regulations The use of video and audio surveillance systems is in general strictly regu lated Inform yourself about the currently valid laws and regulations regarding data worker and en...

Page 9: ...vided exclusively on the website www dallmeier com Read the complete product documentation for the device carefully and thor oughly before using the device Always follow the contained instructions notes and warnings and observe the technical specifications in the currently valid product data sheet Keep all documents in legible condition and in a suitable location for future reference Regularly che...

Page 10: ...oid damage to the device by electrical surge during lightning storms all protective measures which are specified by the currently applicable DIN VDE and ISO standards and which provide for a standard compliant lightning protec tion equipotential bonding are mandatory and must be fulfilled by all means Operating Conditions Unfavorable operating conditions may shorten the lifetime of the device and ...

Page 11: ...ect the device from the PoE enabled PSE port Contact the sales partner responsible for your area Opening The device may only be opened by qualified personnel for commissioning inspection maintenance and repair Disposal Do not dispose waste electrical and electronic equipment into the household trash Disconnect the device from the power supply Remove all connected devices Return the device to the s...

Page 12: ...g insert and sealing ring on connection thread Product documentation published in print and or on DVD ROM The scope of delivery may differ depending on the ordered equipment device variant or country of destination Transportation and Packaging Store the original packaging for later transportation Dallmeier is not responsible for any damage resulting from unprofessional or improper transportation T...

Page 13: ...allations in suspended ceilings or drywall plasterboard systems and can be operated with Power over Ethernet PoE Class 0 IEEE 802 3af or optionally powered by an external 12V DC power supply unit only if the device is equipped ex factory with the Interface Board Series 5100 NOTICE Damage to the device due to an unsuitable mounting location The device is exclusively designed for indoor use An outdo...

Page 14: ...must be installed if the BNC interface is permanently in use If the device or the cables connected to the device are located near sources with strong radiation the video image may be distorted The device is equipped with Automatic Gain Control AGC In low light condi tions the image may be altered e g noise This is not a malfunction The quality of the video image depends on the lighting conditions ...

Page 15: ...A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interfer ence to radio communications Op...

Page 16: ...ten the lifetime of the device and may cause malfunctions or damages Do not install operate the device in places with a large amount of dust and dirt with steam or oil vapors e g kitchen with direct sunlight with strong heat emissions e g radiator with improper ambient temperatures near sources with strong radiation e g radio transmitters magnetic fields with corrosive surroundings e g gases salt ...

Page 17: ... parts and due to the lack of or improper grounding earthing Risk of death or serious injury The installation of the device and the connection of peripheral equipment may only be carried out by qualified personnel and in a voltage free state Before connecting or disconnecting an external DC power sup ply unit make sure that the power supply unit is disconnected from the mains socket pull the power...

Page 18: ...ly unit Damage to the device or malfunctions due to the lack of or im proper grounding earthing Damage to electronic components caused by lightning strikes and over voltages electrical surges or malfunctions due to electro magnetic interferences Carry out all protective measures for a standard compliant grounding earthing and a correct equipotential bonding of the device in accordance with the cur...

Page 19: ...between the contacts rises sharply when un mating the jack plug connection The more un mating cycles are carried out under PoE load the higher the loss of contact material due to metal evaporation by electrical arcs which in turn accelerates the material erosion pro cess on the contact surfaces Damaged contacts with an increased contact resistance may lead to a reduced data transfer rate unreliabl...

Page 20: ...safety Cleaning If it is necessary to clean the device observe the following notes NOTICE Damage to the surfaces of the device due to improper cleaning practices Clean the housing outside with a clean soft dry and antistatic cloth Do not use detergents Clean the plastic dome bubble with water and some hand dishwashing liquid using a clean soft and non linting cloth or sponge Do not rub the plastic...

Page 21: ......

Page 22: ...afety cable steel wire rope with two loops and carabiner Phillips screwdriver PH1 Optional PG16 cable gland or rubber cable grommet WARNING Personal injury caused by falling device or collapsing ceiling Risk of death or serious injury to the head Observe the manufacturer s instructions regarding the maxi mum permissible carrying capacity of the supporting structure and the suspended ceiling or cei...

Page 23: ... 2018 Dallmeier www dallmeier com 23 Commissioning DDF51 X 0HDV DN IM ⓐ ⓐ Torx screwdriver with hollow point T20 H ...

Page 24: ...www dallmeier com DDF51 X 0HDV DN IM Commissioning Loosen the three tamper resistant torx screws Torx TR 20 of the cover ring using a torx screwdriver with hollow point T20 H ⓐ ⓐ 3 Tamper resistant torx screw Torx TR 20 ...

Page 25: ... 2018 Dallmeier www dallmeier com 25 Commissioning DDF51 X 0HDV DN IM Remove the dome cover cover ring with bubble from the housing ...

Page 26: ...26 2018 Dallmeier www dallmeier com DDF51 X 0HDV DN IM Commissioning Screw an M6 eye bolt onto the bottom side of the housing ⓐ ⓐ M6 eye bolt ⓑ Cat 5e RJ45 adapter cable ⓒ Ceiling clamp 2 ⓑ ⓒ ...

Page 27: ...meier www dallmeier com 27 Commissioning DDF51 X 0HDV DN IM Cut a circular hole Ø 143mm into the suspended ceiling or ceiling panel Screw a ceiling hook into the supporting structure ⓐ ⓑ ⓐ Ø 143mm ⓑ Ceiling hook ...

Page 28: ...ning NOTE This step is only necessary for the following scenarios 1 Cabling the Interface Board Series 5100 see page 40 2 Inserting a memory card see page 42 Disconnect the pre assembled Cat 5e RJ45 adapter cable Unscrew the three fixing screws of the camera module ...

Page 29: ... DDF51 X 0HDV DN IM Phillips PH1 3 Lock washer 3 Remove the three fixing screws and the three toothed lock washers from the camera module Proceed with caution and be focused when removing the camera module to avoid losing any screws or other components ...

Page 30: ...30 2018 Dallmeier www dallmeier com DDF51 X 0HDV DN IM Commissioning Rubber cable grommet PG16 cable gland ...

Page 31: ...0 Observe the chapter Interfaces on page 40 Route the required cables through the supplied PG16 cable gland or a suitable rubber cable grommet Screw the PG16 cable gland into the thread on the bottom side of the housing or insert the rubber cable grommet into the corresponding through hole Carry out the cabling Scenario 2 Inserting a memory card Insert a suitable memory card into the memory card s...

Page 32: ... NOTE Before inserting the housing observe the intended camera viewing direction as well as the maximum permissible pan tilt and roll range of the 3 axis camera gimbal as shown on page 36 Insert the housing into the circular cut out ⓐ ⓐ Basic position of ceiling clamps ...

Page 33: ...33 Commissioning DDF51 X 0HDV DN IM Attach a suitable safety cable steel wire rope with two loops to the M6 eye bolt use carabiner and the ceiling hook to properly secure the camera from falling down ⓐ Carabiner ⓑ Steel safety cable ⓐ ⓑ ...

Page 34: ...34 2018 Dallmeier www dallmeier com DDF51 X 0HDV DN IM Commissioning ⓑ ⓐ M4 locking screw ceiling clamp ⓑ Phillips screwdriver ⓐ ⓐ ...

Page 35: ...18 Dallmeier www dallmeier com 35 Commissioning DDF51 X 0HDV DN IM Tighten the M4 locking screw of both ceiling clamps with a Phillips screw driver until the housing is securely fixed Locked ceiling clamps ...

Page 36: ...36 2018 Dallmeier www dallmeier com DDF51 X 0HDV DN IM Commissioning Pan Max 90 Roll Max 180 Tilt Max 45 45 Maximum permissible pan tilt and roll range ⓐ ⓐ ⓐ Knurled thumb screw roll axis ...

Page 37: ...itch or a corresponding PoE midspan device Establish an Ethernet connection to the camera with your web browser see chapter Connection and Login on page 49 Log in to the camera s web based graphical user interface see section Login on page 51 Open the Lens control camera dialog Point the camera at your scene NOTICE Observe the maximum permissible pan tilt and roll range of the 3 axis camera gimbal...

Page 38: ... DN IM Commissioning Attach the dome cover cover ring with bubble back to the housing NOTICE Make sure that the ambient light sensor is not covered by the black inner liner rotate the bubble as required ⓑ Black inner liner ⓐ Ambient light sensor ⓑ ⓐ ...

Page 39: ... 2018 Dallmeier www dallmeier com 39 Commissioning DDF51 X 0HDV DN IM Tighten the three tamper resistant torx screws Torx TR 20 of the cover ring using a torx screwdriver with hollow point T20 H ...

Page 40: ...40 2018 Dallmeier www dallmeier com DDF51 X 0HDV DN IM Commissioning 9 Interfaces ⓐ ⓑ ⓒ ⓓ ⓔ ⓕ ⓖ ...

Page 41: ...face Board Series 5100 To connect cables to the Interface Board Series 5100 you have to remove the camera module first see optional step on page 28 ⓐ Analog video preview output BNC CVBS 1 0Vp p 75Ω ⓑ LAN PoE RJ45 jack PoE conformity IEEE 802 3af ⓒ Contact IN OUT ⓕ RS485 full duplex half duplex ⓓ Audio Line OUT 3 5mm phone jack for stereo TRS plug ⓖ Power IN Weidmüller male connector SL 3 50 02 90...

Page 42: ...42 2018 Dallmeier www dallmeier com DDF51 X 0HDV DN IM Commissioning 10 Inserting a Memory Card ⓐ microSDXC card optional ⓐ ...

Page 43: ...ct card insertion Make sure that the contacts of the used memory card are facing forward and upwards when inserting it into the memory card slot of the camera as shown in the preceding figure For inserting a memory card you have to remove the camera module first see optional step on page 28 The memory card automatically locks into place by use of a spring mechanism when it is inserted into the mem...

Page 44: ...nection To disconnect the conductors from the push in terminal blocks again gently in sert a micro precision screwdriver type flat bladed blade thickness 0 4mm blade width 2 0mm or a similar tool into the rectangular opening below each conductor and pull out the conductor Note however that disconnecting the conductors is only possible after the camera module has been removed see optional step on p...

Page 45: ...n 20 26AWG Pin No Function Pin No Function 1 GND isolated 2 Contact IN 2 3 GND isolated 4 Contact IN 1 5 Contact OUT 1A 6 Contact OUT 1B 7 Contact OUT 2A 8 Contact OUT 2B Contact IN 1 2 For use with potential free switching contacts Contact OUT 1 2 Open drain output max 5V DC 500mA potential free low impedance connection 1 2 3 4 5 6 7 8 ...

Page 46: ... connection for conductor cross section 20 26AWG RS485 Full duplex RS485_A RX Non inverting Receiver Input RS485_B RX Inverting Receiver Input RS485_Y TX Non inverting Driver Output RS485_Z TX Inverting Driver Output RS485 Half duplex RS485_Y TX RX Non inverting Driver Output and Non inverting Receiver Input RS485_Z TX RX Inverting Driver Output and Inverting Receiver Input 1 2 3 4 5 6 ...

Page 47: ...3Vp p Input impedance 29kΩ Audio Line OUT stereo Output level at 10kΩ load max 3 11Vp p Output impedance 320Ω Audio Line IN stereo Line OUT stereo Tip Left channel Left channel Ring Right channel Right channel Sleeve Ground Ground Audio Line IN Line OUT each 3 5mm phone jack for stereo TRS plug Tip Ring Sleeve ...

Page 48: ...o comply with UL s requirements only use a UL certified Limited Power Source LPS power supply unit when powering the device by an exter nal DC power supply unit 12V DC Power IN Weidmüller male connector SL 3 50 02 90G mating connector Weidmüller BL 3 50 02 180 SN Power IN Power IN ...

Page 49: ...the device with Power over Ethernet a single port PoE injector is additionally required To configure the device the client PC must meet the following system require ments System Requirements Operating system OS Microsoft Windows 7 10 each with latest service pack Web browser Microsoft Internet Explorer 11 Windows 7 Microsoft Edge Windows 10 Google Chrome Mozilla Firefox latest available version of...

Page 50: ...can establish an Ethernet connection to the device if necessary contact your network administrator for more information and assistance Start the web browser Enter the IP address of the device into the address bar of the web browser Confirm the input The connection to the device is then established After the successful connection to the device the login dialog is displayed ...

Page 51: ...ccount are User name admin Password 3 NOTICE Risk of unauthorized access to the device and intentional misuse of the system Change the default login credentials of the administrator account as soon as possible Enter your login credentials Confirm with OK After the successful login the graphical user interface of the configuration mode is displayed Configure all required settings e g zoom and focus...

Page 52: ...02 3af Optional Interfaces Interface Board Series 5100 Contact IN OUT 2 Contact IN 2 Contact OUT Serial interface 1 RS485 full duplex half duplex Audio Line IN stereo 1 3 5mm phone jack for stereo TRS plug Input level max 2 83Vp p Input impedance 29kΩ Audio Line OUT stereo 1 3 5mm phone jack for stereo TRS plug Output level at 10kΩ load max 3 11Vp p Output impedance 320Ω Power IN 1 Weidmüller male...

Page 53: ...s 0 12V DC only with Interface Board Series 5100 PoE standard IEEE 802 3af Power consumption Max 6W Mechanical Data Gimbal 3 axis gimbal for manual adjustment pan tilt roll Bubble Clear with black inner liner Vandal resistant Yes IK protection IK10 protection against external mechanical impacts up to 20 joules Color Housing black Cover ring white Dimensions Approx Ø170 H135mm Ø6 7 H5 3 Weight Appr...

Page 54: ...tion sites Indoor Operating temperature 20 C to 50 C 4 F to 122 F Relative humidity 0 90 RH non condensing Approvals Certifications Type CE FCC RCM UL DIN 50130 4 compliant For detailed technical specifications and possible updates see the currently valid product data sheet that is available on www dallmeier com ...

Page 55: ... 2018 Dallmeier www dallmeier com 55 Commissioning DDF51 X 0HDV DN IM 14 Dimensions 134 70 mm 5 30 142mm 5 59 114 60mm 4 51 170mm 6 69 60mm 2 36 14mm 0 55 62mm 2 44 28 80mm 1 13 41 50 mm 1 63 Housing ...

Page 56: ...56 2018 Dallmeier www dallmeier com DDF51 X 0HDV DN IM Commissioning 150mm 5 91 Cat 5e RJ45 adapter cable with rubber grommet ...

Page 57: ......

Page 58: ......

Page 59: ......

Page 60: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 941 8700 0 Fax 49 941 8700 180 www dallmeier com info dallmeier com ...

Reviews: