59
ALC 01
This alarms triggers if the con-
trol system does not receive any
impulse from the group flow-
meter when coffee is being dis-
pensed from group 1.
PROBABLE CAUSES ARE:
• Flowmeter is locked
• Flowmeter connecting cable is
not properly connected
CONSEQUENCES:
• Anomaly is signaled. Dispen-
sing will be locked depending on
the time that has been set du-
ring dose set up
ALC 02
This alarm concerns group 2
ALC 03
This alarm concerns group 3
ALT 01
This alarm triggers three minu-
tes after pressing the manual
free doses button of group 1 wi-
thout switching it off.
PROBABLE CAUSES ARE:
• User’s negligence
CONSEQUENCES:
• Anomaly is signaled and dis-
pensing locked.
To cancel the alarm, press the
CANC button below the display
ALT 02
This alarm concerns group 2
ALT 03
This alarm concerns group 3
ALM 01
This alarms triggers when the
pre-set number of cycles of
group 1 solenoid valve is reached.
To cancel the alarm, press the
CANC button below the display
ALM 02
This alarm concerns the cycle
counter of group 2 solenoid valve
ALM 03
This alarm concerns the cycle
counter of group 3 solenoid valve
ALM 05
This alarm concerns the cycle
counter of the pump
ALM 06
This alarm concerns the cycle
counter of the auto-fill solenoid
valve
ALM 07
This alarm concerns the cycle
counter of the tea solenoid valve
ALM 08
This alarm concerns the cycle
counter of the MCS solenoid valve
Summary of Contents for DC Pro
Page 2: ......
Page 33: ...33...
Page 61: ...61...
Page 91: ...91...
Page 121: ...121...
Page 153: ...Schema elettrico Wiring diagram Schaltpl ne Esquema el ctrico Sch ma lectrique 153...
Page 154: ...154 154...
Page 155: ...155...
Page 167: ...167...