Alarm
Cause
Effect
Timeout
Gp.3
This alarm is triggered when brewing
on group 3 by means of the P5 continuous
delivery button for more than 120 seconds
The brew group is switched
off; tap DEL on the display
to cancel the alarm
Steam
timeout
This alarm is triggered during steam delivery
through the MCS when the milk temperature
probe does not reach 30 °C within 60 seconds
The steam supply is
blocked; tap DEL on the
display to cancel the alarm
Boiler
timeout
This alarm is triggered when the boiler has
not reached the temperature of 40 °C within
10 minutes from when it was activated
Boiler heating is blocked;
tap DEL on the display
to cancel the alarm
Boiler
sensor
interrupted
This alarm is triggered when the boiler
temperature sensor is out of range
Boiler heating is blocked;
tap DEL on the display
to cancel the alarm
Boiler
sensor failure
(short circuit)
This alarm is triggered when the boiler
temperature sensor is out of range
Boiler heating is blocked;
tap DEL on the display
to cancel the alarm
High boiler
temperature
This alarm is triggered when the boiler
temperature sensor has exceeded 127 °C
Boiler heating is blocked;
tap DEL on the display
to cancel the alarm