INSTALLER’S INSTRUCTIONS   

 

 

                      

 

RELEASE 7.03 

Without the GCS

 system the display shows  

 

C  O  F  F  E  E  -  G  R  O  U  P  -  N  .  1 
 

 

s  1  -  =  -  -  1  5  0  -  -  -  -  - 

S1 (single short coffee ) blinks , push

 or 

  to increase or decrease the value( default is 150) 

Press 

OK

 to confirm    

 

C  O  F  F  E  E  -  G  R  O  U  P  -  N  .  1 
 

 

s  2  -  =  -  -  3  0  0  -  -  -  -  - 

S2 (double short coffee ) blinks, push

 or 

  to increase or decrease the value(default is 300) 

Press 

OK

 to confirm    

C  O  F  F  E  E  -  G  R  O  U  P  -  N  .  1 
 

 

s  3  -  =  -  -  1  9  0  -  -  -  -  - 

S3 (single long coffee ) blinks, push

 or 

  to increase or decrease the value(default is 190) 

 Press 

OK

 to confirm    

C  O  F  F  E  E  -  G  R  O  U  P  -  N  .  1 
 

 

s  4  -  =  -  -  3  6  0  -  -  -  -  - 

S4 (double long coffee ) blinks, push

 or 

  to increase or decrease the value(default is 360) 

 Press 

OK

 to confirm    

C  O  F  F  E  E  -  G  R  O  U  P  -  N  .  2 
 

 

s  1  -  =  -  -  1  5  0  -  -  -  -  - 

S1 (single short coffee ) blinks , push

 or 

  to increase or decrease the value(default is 150) 

Press 

OK

 to confirm. Repeat for each group until the display shows  

-  -  T  E  A  -  -  -  G  R  O  U  P  -  -  - 
S  1  =  -  3  .  0  -  -  S  2  =  -  6  .  0 
S1(single hot water dose)blinks, push

 or 

  to increase or decrease the value( defualt is 3.0)  Press 

OK

 

to confirm. S2 ( double hot water dose ) blinks , push

 or 

  to increase or decrease the value( defualt is 

6.0)  Press 

OK

 to confirm.  

Keep pressing the OK button until the display exits the DOSES menu and displays 

 

-  -  T  E  M  P  E  R  A  T  U  R  E  S  -  - 
S  E  T  T  I 

N  G  S  -  -  -  D  O  S  E  S 

 

 
With  the GCS

 system the display shows

 

 

-  -  G  R  .  1  -  -  -  S  e  l  .  1  -  - 
Q  1  =  -  1  5  0  -  -  t  1  =  -  -  2  0 
The display shows: Q1 dose from the selection 1 to the group 1 ( single short coffee ) using Grinder 1

 

You are not allowed to  modify these parameters by using the serial palmer. 

 

Press 

OK

 to confirm ,  the display shows 

-  -  G  R  .  1  -  -  -  S  e  l  .  1  -  - 
Q  1  =  -  1  5  0  -  -  t  2  =  -  -  2  0 
The display shows : Q1 dose from selection 1 to the group 1 (single short coffee)using the Grinder 2 

 

Press 

OK

 to confirm ,  the display shows 

-  -  G  R  .  1  -  -  -  S  e  l  .  2  -  - 
Q  1  =  -  3  0  0  -  -  t  2  =  -  -  2  0 
The display shows : Q1 dose from selection 2 to the group 1 (double short coffee)using the Grinder 1  

 

Press 

OK

 to confirm ,  the display shows 

-  -  G  R  .  1  -  -  -  S  e  l  .  2  -  - 
Q  2  =  -  3  0  0  -  -  t  2  =  -  -  2  0 
The display shows : Q2 dose from selection 2 to the group 1 (double short coffee)using the Grinder 2

 

Going on this way you will visualize all doses parameters referred to the installed groups until the display 
wil show TEA GROUP as already shown in the “WITHOUT GCS SUBMENU” 
Sel 1 = single short coffee 
Sel 2 = double short coffee 

Summary of Contents for 20.03 EVOLUTION

Page 1: ...l n ANNO 2007 MOD 20 03 EVOLUTION 400 V 3N Hz 50 60 230 V 3 230 WATT IPX2 Maximum water pressure 0 6 Mpa ATTENTION End user must set up electrical water and drain systems in advance to ensure a correc...

Page 2: ...data tag applied to the unit Should the power cord be replaced for any reason use only a type with specs recommended by the manufacturer Machine can be operated safely only if properly grounded Machin...

Page 3: ...such connector are distanced at least 3 mm from each other The operation described here above can be performed in two ways Connection to electrical circuit via suitable connector ATTENZIONE Perform in...

Page 4: ...le hoses SYSTEM WITH WATER SOFTENER Softener is recommended in locations where water has over 10 French degrees of total hardness since it will prevent buildup of calcium deposits inside the machine T...

Page 5: ...g espresso Buttons P2 and P5 are programmed the same way by using the double filter basket instead of the single By programming the doses on group nr 1 the same parameters are automatically copied on...

Page 6: ...lect desired item on the menu chosen item will blink and push OK to confirm selection SET MENU Pushing OK while SET is blinking on the main menu will give access to the boiler and group heads temperat...

Page 7: ...E T T I N G S D O S E S From the main menu push or until SETTINGS blinks and press OK to access the settings submenu G R O U P N x O N 2 This parameter sets the electronic board to match the number of...

Page 8: ...his parameter sets the erogation time range allowed within which the erogation itself is considered correct referring to the lay out time already setted Default is 5 Range is between 5 to 20 Push or t...

Page 9: ...water dose blinks push or to increase or decrease the value defualt is 6 0 Press OK to confirm Keep pressing the OK button until the display exits the DOSES menu and displays T E M P E R A T U R E S S...

Page 10: ...0 0 Push to scroll down the submenu and display number of doses dispensed by group 1 T O T A L G R 1 0 0 0 0 0 0 Pushing will display R E S E T C O U N T E R S Y E S N O Pushing will display Select Y...

Page 11: ...o scroll down the submenu until the display shows C H E C K G R I N D I N G 1 0 0 Push to scroll down the submenu C O U N T E R G R I N D I N G T E M P E R A T U R E S Push or to select TEMPERATURE an...

Page 12: ...probes T P R O B E B O I L E R 1 2 1 0 C By pressing you see the probes n 1 2 3 and 4 one after the other T P R O B E G R 1 9 4 8 C Note The temperatures of the probes shown on the screen will range...

Page 13: ...pressing OK again you go back to the OFF status By pressing you go to TRIAC 2 TRIAC 3 TRIAC 4 if they have been installed By pressing you go to RELAY STEAM solenoid valve of the MCS Milk Control Syst...

Page 14: ...ne lockup LED s 7 and 8 turn on and machine emits a continuous beep To cancel the alarm turn the main switch of the machine off and back on This alarm is triggered when the electronic board senses the...

Page 15: ...g button being used blinks To stop dispensing press button P3 of group 3 To cancel the alarm turn the main switch of the machine off and back on This alarm is triggered when the electronic board canno...

Page 16: ...16 INSTALLER S INSTRUCTIONS RELEASE 7 03 WIRING DIAGRAM...

Page 17: ...17 INSTALLER S INSTRUCTIONS RELEASE 7 03...

Page 18: ...4 solenoid valve Ev the Hot water solenoid valve Rs gr1 Group 1 heating element Rs gr2 Group 2 heating element Rs gr3 Group 3 heating element Rs gr4 Group 4 heating element Ts1 Group 1 safety thermost...

Page 19: ...19 INSTALLER S INSTRUCTIONS RELEASE 7 03 12 1 2 3 4 5 11 13 6 7 8 9 10 P1 Led1 P2 Led2 Led3 P3 Led6 P6 P5 Led4 P4 Led10 Led9 P7 Led8 Led7 Led5 GR 1 GR 2...

Page 20: ...2 Adjustable foot 13 Hot water dispensing buttons P1 Dose button One short coffee P2 Dose button Two short coffees P3 Free dose and or Stop button P4 Dose button One long coffee P5 Dose button Two lon...

Reviews: