14 

INSTALLER’S INSTRUCTIONS   

 

 

                      

 

RELEASE 7.03 

By pressing  

 you check the proper functioning of the GCS – grinder control system 

-  -  -  -  -  G  R  I  N  D  E  R  -  -  -  - 
-  -  -  -  -  -  P  A  S  S  -  -  -  -  -  - 
If you see PASS on the screen  it means that the connection is OK 

 

Keeping on pressing ON for  10 seconds ,you go out of the menu “test” , the machine makes a general  
reset  and goes back to its normal functions starting with the heating phase. 

 

ALARMS MENU 

Push 

 or 

 to select ALLARMI from the menu and press 

OK

 to confirm 

After confirmation, any alarm messages stored in the CPU’s memory board since the last reading are 
displayed. If no alarm occurred and was stored in memory, the display shows 

 

 
 
 

Press 

OK

 to exit the ALLARMI submenu and go back to the main menu 

  S  E  T   

-    V  I  S  U  A  L  -  -  - 

  A  L  A  R  M  -  -    -   

T  E  S  T   

 
 

 
 
 
 

I

n addition to storing the programs of all above described functions, the electronic board of this espresso 

machines also controls their proper execution. 
The incorrect execution of any of these functions triggers an alarm, recorded in the alarms menu.  
The available alarms are: 

 

Loss of memory data 

LED’s of all buttons P6 turn on and machine emits 3 beeps. To cancel the alarm turn the main switch of 
machine off and back on. This alarm could be triggered due to strong spikes in the power supply. In case 
of memory loss, machine will operate with factory (default) parameters. 

 

Transformer 

Total machine lockup, LED’s 7 and 8 turn on and machine emits a continuous beep. To cancel the alarm 
turn the main switch of the machine off and back on. This alarm is triggered when the electronic board 
senses the lack of load from the safety transformer, therefore all solenoid valves stop operating. 
 

 

Auto-fill system 

Boiler lockup, LED # 7 blinks and machine emits 3 beeps. To cancel the alarm turn the main switch of the 
machine off and back on. This alarm is triggered when the electronic board senses that the auto-fill probe 
contact remains open beyond the time-out time (programmed in the setting menu) 

 

Safety level 

Boiler lockup. LED # 7 blinks, LED # 8 turn off and machine emits 3 beeps. To cancel the alarm turn the 
main switch of the machine off and back on. This alarm is triggered when the electronic board senses that 
the safety probe (long probe) contact remains open for over 30 seconds. 

 

Temperature probe BOILER 

Boiler lockup, LED # 8 blinks and machine emits 3 beeps. To cancel the alarm turn the main switch of the 
machine off and back on. This alarm  is triggered when the electronic board senses that the readings of 
the temperature probe boiler are out of range 

 

Temperature probe Group 1 

Group 1 lockup, LED # 6 of group 1 blinks and machine emits 3 beeps. To cancel the alarm turn the main 
switch of the machine off and back on. This alarm is triggered when the electronic board senses that the 
readings of the temperature probe in group 1 are out of range 

 

Temperature probe Group 2 

-  -  -  -  A  L  A  R  M  -  -  -  -  -  -  - 
-  E  M  P  T  Y  -  M  E  M  O  R  Y  -  -  - 

ALARMS ADMINISTRATION 

Summary of Contents for 20.03 EVOLUTION

Page 1: ...l n ANNO 2007 MOD 20 03 EVOLUTION 400 V 3N Hz 50 60 230 V 3 230 WATT IPX2 Maximum water pressure 0 6 Mpa ATTENTION End user must set up electrical water and drain systems in advance to ensure a correc...

Page 2: ...data tag applied to the unit Should the power cord be replaced for any reason use only a type with specs recommended by the manufacturer Machine can be operated safely only if properly grounded Machin...

Page 3: ...such connector are distanced at least 3 mm from each other The operation described here above can be performed in two ways Connection to electrical circuit via suitable connector ATTENZIONE Perform in...

Page 4: ...le hoses SYSTEM WITH WATER SOFTENER Softener is recommended in locations where water has over 10 French degrees of total hardness since it will prevent buildup of calcium deposits inside the machine T...

Page 5: ...g espresso Buttons P2 and P5 are programmed the same way by using the double filter basket instead of the single By programming the doses on group nr 1 the same parameters are automatically copied on...

Page 6: ...lect desired item on the menu chosen item will blink and push OK to confirm selection SET MENU Pushing OK while SET is blinking on the main menu will give access to the boiler and group heads temperat...

Page 7: ...E T T I N G S D O S E S From the main menu push or until SETTINGS blinks and press OK to access the settings submenu G R O U P N x O N 2 This parameter sets the electronic board to match the number of...

Page 8: ...his parameter sets the erogation time range allowed within which the erogation itself is considered correct referring to the lay out time already setted Default is 5 Range is between 5 to 20 Push or t...

Page 9: ...water dose blinks push or to increase or decrease the value defualt is 6 0 Press OK to confirm Keep pressing the OK button until the display exits the DOSES menu and displays T E M P E R A T U R E S S...

Page 10: ...0 0 Push to scroll down the submenu and display number of doses dispensed by group 1 T O T A L G R 1 0 0 0 0 0 0 Pushing will display R E S E T C O U N T E R S Y E S N O Pushing will display Select Y...

Page 11: ...o scroll down the submenu until the display shows C H E C K G R I N D I N G 1 0 0 Push to scroll down the submenu C O U N T E R G R I N D I N G T E M P E R A T U R E S Push or to select TEMPERATURE an...

Page 12: ...probes T P R O B E B O I L E R 1 2 1 0 C By pressing you see the probes n 1 2 3 and 4 one after the other T P R O B E G R 1 9 4 8 C Note The temperatures of the probes shown on the screen will range...

Page 13: ...pressing OK again you go back to the OFF status By pressing you go to TRIAC 2 TRIAC 3 TRIAC 4 if they have been installed By pressing you go to RELAY STEAM solenoid valve of the MCS Milk Control Syst...

Page 14: ...ne lockup LED s 7 and 8 turn on and machine emits a continuous beep To cancel the alarm turn the main switch of the machine off and back on This alarm is triggered when the electronic board senses the...

Page 15: ...g button being used blinks To stop dispensing press button P3 of group 3 To cancel the alarm turn the main switch of the machine off and back on This alarm is triggered when the electronic board canno...

Page 16: ...16 INSTALLER S INSTRUCTIONS RELEASE 7 03 WIRING DIAGRAM...

Page 17: ...17 INSTALLER S INSTRUCTIONS RELEASE 7 03...

Page 18: ...4 solenoid valve Ev the Hot water solenoid valve Rs gr1 Group 1 heating element Rs gr2 Group 2 heating element Rs gr3 Group 3 heating element Rs gr4 Group 4 heating element Ts1 Group 1 safety thermost...

Page 19: ...19 INSTALLER S INSTRUCTIONS RELEASE 7 03 12 1 2 3 4 5 11 13 6 7 8 9 10 P1 Led1 P2 Led2 Led3 P3 Led6 P6 P5 Led4 P4 Led10 Led9 P7 Led8 Led7 Led5 GR 1 GR 2...

Page 20: ...2 Adjustable foot 13 Hot water dispensing buttons P1 Dose button One short coffee P2 Dose button Two short coffees P3 Free dose and or Stop button P4 Dose button One long coffee P5 Dose button Two lon...

Reviews: