17
Image menu function table
Items
Operation function
Polarity:White
hot/Black hot
Two choice to set thermal imager polarity:
White hot:White color shows high temperature
zone,black color shows low temperature zone.
Black hot:Black color shows high temperature
zone, white color shows low temperature zone
Factory setting is white hot
Mode:
Auto/Semi-Auto/
Manual
Select
image
mode
as
automatic
,
semi-automatic or manual.General observations
preferred automatic mode, the small target
observation suggested the use of semi-automatic
mode can achieve better results. The factory
setting is fully automatic mode.
When the image mode is set to " Auto" , the
brightness and gain value of the image will
automatic
adjustment
,
no
need
manual
adjustment
;
When the image mode is set to " Semi-Auto" , only
gain value can be adjustment, brightness value
is still on automatic adjustment
;
When the image mode is set to "Manual ", both
brightness and gain value of the image can be
adjusted .
Gain:XX
Display and set current gain value for image
Brightness:XX
Display and set current brightness value for
image
Filtering:On/Off
Default On
Enhance:
Off/Low/Middle/
High
Default Off,
when using the remote observation
of small targets , please open the image
enhancement , switching low, middle and high to
see the best image
Zoom:1×/2×/3×
/4×
Four choice to set current electrical zoom:
1×:No enlarge;
2×/3×/4×:Enlarge 2/3/4 multiple centered on
cross
Return:
Back to superior menu