TRIMAX 520
Page 23
Hydraulic 3D stone control
The working pressure is adjusted to around 70 bar = green area on the
manometer (A). The actual pressure can be controlled continuously on the
manometer (A). After the adjustments have been done, shut the ball plug
valve (B) and the hydraulic hose can be disconnected from the tractor. If the
ball plug valve is not shut, the oil will slowly seep back to the tractor and the
pressure on the installation will fall, since the outlet on the tractor is not
completely sealed.
Fig. 14
A
B