MAXICUT
Side 22
Activate cylinders after assembly. Activate cylinders both ways, retract-
ing/extending fully in both outer positions. This is necessary to bleed the system
and cylinder.
Ensure no personnel are within the extension radius of the side sections.
Replacing gasket set for extend/retract cylinder
Fig. 9
1.
For cylinder removal, see ”
Replacing extend cylinder for retracting side sec-
2.
Drain oil from cylinder by moving ram carefully backwards and forwards.
3.
Extend ram to centre position. Unscrew upper part (pos. 3) from cylinder tube
(pos. 1). Use special tool to remove upper part. If upper part is stuck, heat front
of sleeve. When upper part is detached from cylinder tube, pull ram up towards
upper part and remove completely from cylinder tube.
4.
Remove lock nut retaining collar shoe (pos. 4).
5.
Remove collar shoe (pos. 4) from ram.
6.
Remove upper part (pos. 3) from ram.
7.
Remove gaskets in upper part and collar shoe, (pos. 5+6+7+8+9).
8.
Clean all parts and check for particles etc. Check for rust around scraper ring
(pos. 5) in upper part. If detected, remove thoroughly.