2.3 Ventilation Requirements
Reference Drawing:
Shop Dwg, AF-3300-48x48-12-RGB, 32x48-20-R ......
Drawing B-241264
Shop Dwg, AF-3300-48x64-12-RGB, 32x80-20-R ......
Drawing B-240560
Vents are provided in the face of the display for ventilation. Vents and fans draw air
into the display at the bottom, and the warm air is expelled out at the top through
vents in the front. Both of the intake and exhaust vents run the length of the display
and should not be obstructed. Refer to the appropriate
Shop Drawing
for additional
information.
The display cabinet may be completely enclosed on the sides and in the back, so long
as the vents in the face are not obstructed.
If these requirements are not met, the Galaxy
®
display warranty may be void.
2.4 Lifting the Display
The top of the display is equipped with eyebolts that are used to lift the unit. Take
special care to ensure that the rated load of the eyebolts is not exceeded. Refer to the
information at the end of this section labeled
Eyebolts
to determine the allowable
load of the eyebolts shipped with the display.
illustrates both the correct (left example) and the incorrect (right example)
method of lifting a display. Lift the display as shown on the left, with the lifting bar.
Use every lifting point provided.
Figure 8: Lifting the Display (Correct, Left; Incorrect, Right)
Do not attempt to permanently support the display by the eyebolts
.
Eyebolts can be removed for the display to eliminate the need for overheard
clearance.