![Daktronics DB-66 Series Service Manual Download Page 23](http://html1.mh-extra.com/html/daktronics/db-66-series/db-66-series_service-manual_3275656023.webp)
Control Equipment Overview, Service, and Replacement
19
Replace Control Equipment
Replace the DMP-8000
1�
Disconnect the incoming power to the DMP-
8000 by unscrewing the connector.
2�
Disconnect the HDMI cable from the DMP-
8000. Refer to
3�
Disconnect the network communication
cable.
4�
Loosen the screws holding the DMP-8000
bracket to the control enclosure.
5�
Slide the DMP-8000 and bracket upward and
outward to remove it.
6�
Reverse
Steps 1–5
to install the new DMP-8000.
7�
Ensure all cables are installed in the same ports
as on the previous DMP-8000.
Replace the VIP-5160
1�
Disconnect the incoming power to the VIP-5160.
2�
Disconnect the communication cables.
3�
Remove the screw at the bottom of the VIP-5160.
4�
Lift the VIP-5160 and disengage the hooks to remove it.
5�
Reverse
Steps 1–4
to install the new VIP-5160.
6�
Ensure all cables are installed in the same ports as on the previous VIP-5160.
Replace the DMP/VIP Power Supply
The VIP and DMP share a power supply. To
replace a failed power supply:
1�
Disconnect any power cables to the power
supply and from that power supply to the
DMP/VIP.
2�
Push down on the top leg of the wire form
bracket and rotate the power supply
.
3�
Carefully pull the power supply outward.
4�
Reverse
Steps 1–3
to install a replacement power supply.
Figure 30:
DMP-8000 Jacks and Bracket
Figure 31:
DMP/VIP Power Supply Bracket