37
TROUBLESHOOTING FLOWCHART #7
START: Continued
from Troubleshooting
Flowchart #1
Check to see if the RED
LED "D8" in the rear
enclosure on the Circuit
Board is ON. It is located
next to Fuse "F5".
Is RED LED
"D8" ON?
Replace blown
fuse with exact
type and rating
Check SPINNERS
OUTPUT CABLE and
Connectors for
damage and proper fit
Cables and
Connectors
OK?
Make proper
connections and/or
replace damaged
ones
Test the Output
Current going through
the SPINNERS VALVE
SOLENOID.
Do the SPINNERS
move faster & slower as
the SPINNERS SPEED
ADJUSTMENT KNOB Is
turned up & down?
END: Continue
troubleshooting
from FLOWCHART #1
Does the FUSE keep
blowing after replacing
it during this troubleshooting
flowchart usage?
Check FUSE "F5" in
the rear enclosure
on the circuit board
Is Fuse
"F5" OK?
Does the
Output Current
test correctly?
Adjust the minimum &
maximum Current
adjustments to
achieve correct Output
Could the Output
Current be adjusted to the
correct levels?
Test the
Resistance of the
SPINNERS VALVE
SOLENOID
Did SPINNERS
VALVE SOLENOID
test to specifications?
Replace
SPINNERS VALVE
SOLENOID
Troubleshoot
Valve Assembly
Troubleshoot
Valve Assembly
Troubleshoot
Valve Assembly
VALVE
ASSEMBLY
OK?
Contact
Dakota
Repair valve
assembly
Contact
Dakota
Check SPINNERS
OUTPUT Cable and
Connectors for
damage and proper fit
Cables and
Connectors
OK?
Make proper
connections
and/or replace
damaged ones
Test resistance
of the SPINNERS
VALVE SOLENOID
Did the SPINNERS
VALVE SOLENOID
test to specifications?
Replace the
SPINNERS
VALVE
SOLENOID
Contact
Dakota
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
TROUBLESHOOTING