MAINTENANCE
Continuous leakage from the exhaust port when the solenoid
is de-energized can be caused by a foreign particle trapped
between the bottom seat and the plunger, by a damaged bottom
seat, or by a worn or damaged bottom plunger seal. Leakage
at the exhaust port and/or solenoid buzzing when the solenoid
is energized can be caused by a foreign particle lodged in the
top seat area. Leakage in this area can also be caused by
worn or damaged top seats or top plunger seals.
EX
CF
INLET
Manual Override
Orifice Spring Adjust
Factory Preset
Do Not Adjust
NOTE: Most if not all problems are a result of a
foreign particle not allowing the ball to seat.
Cleaning of the seat area with WD40 or equivilent
and compressed air normally returns the valve to a
fully operational status.
Broken springs on spring return valves can cause a valve
to remain in the actuated position or to only partially return
and perhaps leak to exhaust. Broken springs must be replaced.
NOTE: The retaining nut on the top of each
hydraulic valve section requires only firm hand
tightening. Application of excessive force will result
in damage to the valve.
2
1
Remove nut #1.
Loosen nut #2.
Under #1, use a flat-blade
screwdriver, turn all the way
to stop; then turn back out.
HYDRAULIC ROUTING DIAGRAMS
Outside Valve
Inside Valve
Spinner
Motor
Spinner
Motor
Conveyor
Motor
Pressure
Return
10134
14184
10142
14182
14180
14380
14380
CF
IN
EX
CF
IN
410 Electric (Mounted)
14181
10844
410 Electric With Engine
Oil Tank
Pump
Outside Valve
Inside Valve
Spinner
Motor
Spinner
Motor
Conveyor
Motor
14181
10134
14184
10142
14182
14180
14382
CF
IN
EX
CF
IN
14183
Outside Valve
Inside Valve
Spinner
Motor
Spinner
Motor
Conveyor
Motor
Pressure
Return
10134
14184
10142
14182
14180
13558
14383
CF
IN
EX
CF
IN
410 Electric Without Engine
14181