TROUBLESHOOTING (continued) 

PROBLEM 

CAUSE 

SOLUTION 

Fan runs constantly 

Controller has an error 

 

Fan off temp too low 

 

Broken/shorted wire to sender 

 

Wrong gauge is selected 

Check display for error message. 

 

Increase off temp in setup. 

 

Check wire to sender for breaks or shorts and repair. 

 

Select appropriate gauge in setup, or custom calibrate if 
your gauge is not supported. 

Custom gauge setup 
displays “

Err

” and 

returns to “

Snd

” setup 

option 

Not enough points used 
 
Points not input in correct order 
 
Point entered twice 

Make sure that at least 4 points of gauge are set 
 
Set gauge points in order from cold points to hot points 
 
Each point set must be different that the point before it 

Fans cycle on-off 
especially when engine 
temp is close to 
On/off set point  

+12v for controller taken from same 
circuit as the fan power +12V (green 
wire on relays) 

Connect the +12V for the controller to a different circuit 
separate from the circuit connected to fan relays. 

 
 
 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

SERVICE AND REPAIR 

DAKOTA DIGITAL offers complete service and repair of its product line.  In addition, technical consultation is available to help you work through any questions or 

problems you may be having installing one of our products. Please read through the Troubleshooting Guide. There, you will find the solution to most problems. 
Should you ever need to send the unit back for repairs, please call our technical support line, (605) 332-6513, to request a Return Merchandise Authorization 
number.
  Package the product in a good quality box along with plenty of packing material.  Ship the product by UPS or insured Parcel Post.  Be sure to include the RMA 
number on the package, and include a complete description of the problem with RMA number, your full name and address (street address preferred), and a telephone number 
where you can be reached during the day.  Any returns for warranty work must include a copy of the dated sales receipt from your place of purchase.  Send no money.  We will 
bill you after repair.   

 

Dakota Digital 24 Month Warranty 

DAKOTA DIGITAL warrants to the ORIGINAL PURCHASER of this product that should it, under normal use and condition, be proven defective in material or 

workmanship within 24 MONTHS FROM THE DATE OF PURCHASE, such defect(s) will be repaired or replaced at Dakota Digital’s option.  

This warranty does not cover nor extend to damage to the vehicle’s systems, and does not cover removal or reinstallation of the product.  This Warranty does not 

apply to any product or part thereof which in the opinion of the Company has been damaged through alteration, improper installation, mishandling, misuse, neglect, or 
accident. 

This Warranty is in lieu of all other expressed warranties or liabilities.  Any implied warranties, including any implied warranty of merchantability, shall be limited to 

the duration of this written warranty.  Any action for breach of any warranty hereunder, including any implied warranty of merchantability, must be brought within a period of 24 
months from date of original purchase.  No person or representative is authorized to assume, for Dakota Digital, any liability other than expressed herein in connection with 
the sale of this product. 

 
 

 

PAC-2750 specifications 

SETTINGS 

Minimum Fan On Temp 

150° F (65 C) 

Maximum Fan On Temp 

250° F (121 C) 

SUPPLY 

Voltage Input (+12) Range  

6.3 to 22 V 

Key Off Current (+12) 

< 0.001 A 

Key On Current (+12) 

< 0.025 A 

INPUTS 

 

Off voltage  On voltage 

Ignition 

< 2.2 V 

> 5.6 V 

A/C Clutch 

< 2.2 V 

> 5.6 V 

OUTPUTS (to turn on relay) 

Fan Low, High (maximum) 

1.5 A 

Included relay specifications 

Typical Coil Current 

0.175 A 

Relay Contacts Max Current 

70 A (14VDC) 

Summary of Contents for PAC-2750

Page 1: ...V NOT CONNECTED FAN Fan Low Fan High 12V Fan PWR 12V Fan PWR 12V To gauge control box or another BIM Required components for installation The PAC 2750 is shipped with necessary components for use with a single fan on a gauged system These parts include 1 PAC 2750 module 1 RLY 3 relay with wiring harness 1 BIM data cable 1 Instruction manual For some options of the PAC 2750 additional components ar...

Page 2: ...en entering setup mode with a VHX or VFD gauge system and the PAC 2750 connected with a BIM cable the fan will begin running continuously after a 2 minute delay IMPORTANT NOTE If using a gauge with this unit always ensure that your gauge is working properly If the gauge is not reading correctly the fan control unit will not have correct temperature information and cannot be guaranteed to properly ...

Page 3: ... temperature is to be set Use SW1 or SW2 to set the temperature and press both switches to save the setting 7 Display will read dLy Use SW1 or SW2 to cycle through the following options Press both switches to select an option Display Option OFF Fan will turn off when key is turned off 0 5 If fan was running at key off it will continue to run for 30 seconds after key is turned off 0 7 If fan was ru...

Page 4: ...utomatically be started The following is the procedure for custom calibration If your gauge system is listed above skip this portion and continue at Step 12 Custom Calibration Note 1 If your engine is warm you may need to disconnect the wire from your sender in order get to the lower points on the gauge Note 2 If the key is turned off in custom setup the previous gauge setting will be used and the...

Page 5: ...turning off the ignition pressing and holding SW2 and turning ignition back on If a selection cannot be found that closely matches your gauge you may have to custom calibrate to your gauge see Step 10 in setup Testing Fan operation diagnostic mode 2 A second diagnostic mode allows you to test the fan operation for the mode you have set This can be used to verify dual speed dual fan or variable spe...

Page 6: ... prevent excessive battery drain Fan turns on early late or not at all Unit has no constant power Display will not show anything when SW1 is held Unit has no keyed power dot on display flashes rapidly when SW1 is held Broken shorted wire to sender Wrong gauge is selected gauge setup Wrong sender used for no gauge setup Wrong bus type set for BIM gauge setup On temperature in setup is too high Fan ...

Page 7: ...blem with RMA number your full name and address street address preferred and a telephone number where you can be reached during the day Any returns for warranty work must include a copy of the dated sales receipt from your place of purchase Send no money We will bill you after repair Dakota Digital 24 Month Warranty DAKOTA DIGITAL warrants to the ORIGINAL PURCHASER of this product that should it u...

Reviews: