PAC-2750 

ELECTRIC COOLING FAN CONTOLLER 

PAC-2750

FAN CONTROLLER

www.dakotadigital.com

[email protected]

605-332-6513

F

A

N

 H

IG

H

F

A

N

 L

O

W

G

R

O

U

N

D

+

1

2

 B

A

T

S

E

N

D

E

R

A

/C

IG

N

IT

IO

N

B

IM

 I

/O

C

U

S

T

O

M

A

D

J

U

S

T

S

W

1

S

W

2

FAN2

F

an 

P

W

R

 +

12V

LOW

FAN1

FAN

HIGH

+12V

GAUGE

(not used in
sender only 

or BIM 

application)

+12V with key ON

A/C clutch cycle switch (+12V trigger)

Fused battery 12V

Choose
option
below

SENDER
(not used in BIM
application)

GAUGE

single fan

two separate fans

dual speed fan

Fan
High

Fan
High

Fan
Low

Fan
Low

+12V

NOT

CONNECTED

FAN

Fan
Low

Fan
High

+12V

F

an 

P

W

R

 +

12V

Fan 

PWR
+12V

To gauge control box
 or another BIM

+

-

-

-

-

-

-

+

-

+

-

+

-

+

 

Required components for installation: 
The PAC-2750 is shipped with necessary components for use with a single fan on a gauged system. These parts include: 
 

PAC-2750 module 

 

RLY-3 relay with wiring harness 

 

BIM data cable 

 

Instruction manual 

For some options of the PAC-2750, additional components are required. These are listed below. 

- Second RLY-3 assembly (needed for dual fan or two speed fan operation) 
- 300ºF sender Dakota Digital temp sender (for operation without a gauge) 

IMPORTANT NOTE:

  

The +12V for the 
controller should NOT 
be taken from the same 
circuit as the Fan Power 
12V as this can cause 
the fan to cycle on and 
off.  

Summary of Contents for PAC-2750

Page 1: ...V NOT CONNECTED FAN Fan Low Fan High 12V Fan PWR 12V Fan PWR 12V To gauge control box or another BIM Required components for installation The PAC 2750 is shipped with necessary components for use with a single fan on a gauged system These parts include 1 PAC 2750 module 1 RLY 3 relay with wiring harness 1 BIM data cable 1 Instruction manual For some options of the PAC 2750 additional components ar...

Page 2: ...en entering setup mode with a VHX or VFD gauge system and the PAC 2750 connected with a BIM cable the fan will begin running continuously after a 2 minute delay IMPORTANT NOTE If using a gauge with this unit always ensure that your gauge is working properly If the gauge is not reading correctly the fan control unit will not have correct temperature information and cannot be guaranteed to properly ...

Page 3: ... temperature is to be set Use SW1 or SW2 to set the temperature and press both switches to save the setting 7 Display will read dLy Use SW1 or SW2 to cycle through the following options Press both switches to select an option Display Option OFF Fan will turn off when key is turned off 0 5 If fan was running at key off it will continue to run for 30 seconds after key is turned off 0 7 If fan was ru...

Page 4: ...utomatically be started The following is the procedure for custom calibration If your gauge system is listed above skip this portion and continue at Step 12 Custom Calibration Note 1 If your engine is warm you may need to disconnect the wire from your sender in order get to the lower points on the gauge Note 2 If the key is turned off in custom setup the previous gauge setting will be used and the...

Page 5: ...turning off the ignition pressing and holding SW2 and turning ignition back on If a selection cannot be found that closely matches your gauge you may have to custom calibrate to your gauge see Step 10 in setup Testing Fan operation diagnostic mode 2 A second diagnostic mode allows you to test the fan operation for the mode you have set This can be used to verify dual speed dual fan or variable spe...

Page 6: ... prevent excessive battery drain Fan turns on early late or not at all Unit has no constant power Display will not show anything when SW1 is held Unit has no keyed power dot on display flashes rapidly when SW1 is held Broken shorted wire to sender Wrong gauge is selected gauge setup Wrong sender used for no gauge setup Wrong bus type set for BIM gauge setup On temperature in setup is too high Fan ...

Page 7: ...blem with RMA number your full name and address street address preferred and a telephone number where you can be reached during the day Any returns for warranty work must include a copy of the dated sales receipt from your place of purchase Send no money We will bill you after repair Dakota Digital 24 Month Warranty DAKOTA DIGITAL warrants to the ORIGINAL PURCHASER of this product that should it u...

Reviews: