background image

POWER DOOR LOCK WIRING 

GROUND-AT-REST Switch - 
contact positions vary with style

CHASSIS
GROUND

CONSTANT-ON

CHASSIS

+12V  (BATT)

GROUND

TO CONSTANT-ON

+12V (BATT.)

WHITE

BLUE

BROWN

GREEN

PURPLE

DUAL

PACK

RELAY

WHITE/RED

GREEN

small wire

WHITE/BLUE

CONSTANT-ON
FUSED +12V

RED

small wire

BLUE

FUSED +12V

CONSTANT-ON

GROUND

CHASSIS

BLACK

RED

NOTE:  If no switch is to be used,

GROUND the brown and white wires.

 

 

Figure 11.  Connection to power door locks with a 5-wire switch. 

 
WIRING TO RELEASE 4 DOOR LATCHES 
 

Buttons 1 and 2 will operate door latch releases instead of window up/down. For 

solenoids which require more than 10 amps, such as Dakota Digital’s PDR-2, an external relay 
should be used for powering the solenoids on outputs 3 and 4. (see figure 3.) 

FUSED +12V

small wire

BLUE

small wire

GREEN

RED

DO NOT CONNECT

DO NOT CONNECT

ACTIVATED WHEN BUTTON 1 IS PRESSED

ACTIVATED WHEN BUTTON 2 IS PRESSED

TO DOOR LATCH RELEASE

TO DOOR LATCH RELEASE

FUSED +12V

CONSTANT-ON

CHASSIS

RELAY

BROWN

WHITE

GREEN

PACK

BLUE

PURPLE

GROUND

BLACK

DUAL

CONNECT ORANGE AND PINK
WIRES TOGETHER

WIRES TOGETHER

CONNECT WHITE AND GRAY

CONSTANT-ON
FUSED +12V

ORANGE

PINK

GRAY

WHITE

ACTIVATED WHEN BUTTON 4 IS PRESSED

ACTIVATED WHEN BUTTON 3 IS PRESSED

TO DOOR LATCH RELEASE

TO DOOR LATCH RELEASE

CONSTANT-ON

RED

GREEN

BLUE

If high current solenoids (>10A) are 
being used, then wire another dual 
relay pack here as shown in Fig. 3.

 

 

Figure 12.  Connection for operating four door latch releases. 

 

 

Summary of Contents for CMD-9000

Page 1: ...he accidental opening of a door during vehicle operation With the ignition on the only functions that are allowed to work are the control of the power windows An emergency release switch can be concealed on the underside of the vehicle to roll the driver s window down should the door ever be closed with the transmitter on the inside and you on the outside ADDITIONAL TRANSMITTERS The transmitters s...

Page 2: ...latch actuator PURPLE trunk release latch actuator WHITE RED trunk lift motor raise relay WHITE BLUE trunk lift motor lower relay ORANGE passenger s window up relay PINK passenger s window down relay WHITE driver s window up relay GRAY driver s window down relay WHITE GREEN auxiliary relay output The blue green and purple wires are connected to internal relays and can feed 12 volts out at up to 10...

Page 3: ...Y 12 VOLT MOTOR OR SOLENOID MAY BE USED GREEN BLUE BLUE GREEN GREEN BLUE 10 amp max 10 amp max 10 amp max TO CHANGE THE PDR 1 FROM PULL TO PUSH SWITCH THE BLUE AND GREEN WIRES Figure 1 Door and trunk latch wiring diagram MOMENTARY POWER SWITCH FUSED 12 VOLTS ACTUATOR OUTPUT WIRE FROM REMOTE SYSTEM WIRE HARNESS CHASSIS GROUND DOOR OR TRUNK LATCH ACTUATOR Figure 2 Wiring to control actuator with the...

Page 4: ...ORANGE RED WINDOW REGULATOR TO PASSENGER SIDE DUAL RELAY PACK BLUE GREEN PURPLE BLUE GREEN BROWN WHITE DUAL RELAY PACK MANUFACTURER small wire small wire small wire wire small BROWN Driver s Window Emergency Entry Switch GROUND SEALED SWITCH GROUND AT REST Switch contact positions vary with style Figure 4 Connection to Specialty Downs Balls GM and other power window regulators using a 5 wire or ce...

Page 5: ...e 5 Connection to power window regulators with a three wire 12 volt switch CONSTANT ON NOT GROUND AT REST 4 WIRE or 3 WIRE SWITCH FUSED 12V IS NO LONGER CONNECTED CONNECTING A 12V WIRE TO THE SWITCH WILL DAMAGE THE REMOTE CONTROL UNIT DO NOT CONNECT CHASSIS GROUND POWER WIRES NOTE THAT 12V WIRE ON POWER WINDOW SWITCH BLACK BLUE FUSED 12V BLUE BLACK GROUND CHASSIS TO CONSTANT ON REGULATOR AND SWITC...

Page 6: ...act positions vary with style MANUFACTURER VARY DEPENDING ON TRUNK LIFT MAY WIRE COLORS COMING FROM Figure 7 Connection to power trunk lift motor SINGLE RELAY WIRING FOR AUXILIARY OUTPUTS The single relay shown is not included in the base kit These are available from Dakota Digital RLY 1 however any 12 volt automotive relay will work BLACK BLUE 86 87 85 30 GREEN SWITCHED OUTPUT CONSTANT ON FUSED 1...

Page 7: ... LOCK SYSTEM PURPLE WHITE BLUE GREEN BROWN PACK RELAY DUAL GREEN RED BLUE CHASSIS GROUND CONSTANT ON FUSED 12V RED BLACK WHITE RED WHITE BLUE small wire small wire Figure 9 Connection to power door locks with 3 wire 12 volt switch LOCK SYSTEM FACTORY DOOR TO CHASSIS DO NOT CONNECT SWITCH DOOR LOCK GND 12V GND GROUND CHASSIS GROUND CONSTANT ON FUSED 12V PACK WHITE GREEN BROWN WHITE RED FUSED 12V GR...

Page 8: ...kota Digital s PDR 2 an external relay should be used for powering the solenoids on outputs 3 and 4 see figure 3 FUSED 12V small wire BLUE small wire GREEN RED DO NOT CONNECT DO NOT CONNECT ACTIVATED WHEN BUTTON 1 IS PRESSED ACTIVATED WHEN BUTTON 2 IS PRESSED TO DOOR LATCH RELEASE TO DOOR LATCH RELEASE FUSED 12V CONSTANT ON CHASSIS RELAY BROWN WHITE GREEN PACK BLUE PURPLE GROUND BLACK DUAL CONNECT...

Page 9: ...volts for approximately one second Button 5 Trunk latch application Pressing button 5 will activate the third internal relay for about one second The white w blue and white w red wires should not be used Button 5 Trunk lift lock unlock or similar The first time the button is pressed it will raise the trunk or unlock doors until it is released The next time it is pressed it will lower the trunk or ...

Page 10: ...or each button Press and release button 5 and then press one of the other buttons for the functions listed below Pressing button 5 and then button 1 will activate an external relay to raise a trunk lift unlock doors or any other function It will remain on until the button is released Pressing button 5 and then button 2 will activate an external relay to lower a trunk lift lock doors or any other f...

Page 11: ...nd position 4 Replace the battery with a new 12 volt type GP23A battery which is available at most electronic stores Radio Shack battery stores etc 5 Carefully replace the top cover and refasten the screw INSTRUCTIONS FOR TESTING AND PROGRAMMING TRANSMITTERS All of the transmitters to be programmed into the system should be available This sequence will erase any previously programmed transmitters ...

Page 12: ...ETIME OF THE CAR IN WHICH IT WAS ORIGINALLY INSTALLED such defect s will be repaired or replaced at the Company s option without charge for parts or labor directly related to repairs of the defect s To obtain repair or replacement within the terms of this Warranty the product is to be delivered with proof of warranty coverage e g dated bill of sale specification of defects transportation prepaid t...

Reviews: