background image

GB

114

The multicontact detector has a “test” mode for testing:
• the 

battery

: the LED indicator lamp lights up when the test button is

pressed to indicate the battery is working correctly,

• 

detection

: the LED indicator lamp lights up when the contacts (built-in

and  external) change status,

• the 

radio link

: see § on Checking the radio links described in the control

panel manual.

)

)

)

)

)

“beep, detector X, 

group Y immediate (or

delayed or combined)”

7. Testing

IMPORTANT: the control panel must be in installation mode for testing.

Large and small model
waterproof pressure mats

• NO loop type.
• Minimum weight for contact

closing:
- small model: 35 kg
- large model: 40 kg

large model

small model

Summary of Contents for SH271AX

Page 1: ... upgraded for e Nova applications ...

Page 2: ...cal data 118 1 Introduction The multicontact detector is used to protect openings such as doors windows It is fitted with a built in magnetic contact reed switch a terminal block for connecting external contacts such as magnetic contacts flush or surface mounted wide gap etc external roller shutter blind sensors piezo electric glassbreak sensors shock sensors pressure mats other non specific sensors ...

Page 3: ... pre determines the level of alarm generated Nevertheless it is possible to modify the alarm level for the built in or external contact s see on Configuration Type of external contact Alarm level Inactive no contact connected Normally closed contact NC Intrusion Piezo electric glassbreak sensor NC Intrusion Roller shutter blind sensor Intrusion Normally closed contact Prealert for roller shutter bl...

Page 4: ...ashes every 5 sec Guarantee sticker Remove the pre cut part of the sticker and stick it to the guarantee certificate in the user manual supplied with the control panel If you are adding the siren to an existing system use the guarantee sticker provided with this product 2 2 Power supply The lithium battery pack is clipped into position see diagram below An arrow indicates which way to connect it Co...

Page 5: ...tting 3 short beeps When this happens programming should be carried out again 10 s max Press then on the control panel keypad Press and hold the test button until the control panel responds The control panel waits for a group to be chosen from 1 to 8 Choose the groups by pressing the corresponding numeral on the control panel keypad The control panel gives a voice message to confirm detector progr...

Page 6: ...ameter Value corresponding to the characteristics of the contact to be configured Type of contact Parameter n Contact characteristics Parameter vaue Supervised opening Alarm level Built in 1 inactive 1 no active NC factory setting 2 yes intrusion External 3 inactive factory setting 1 no normally closed contact NC 2 yes intrusion roller shutter blind sensor 3 no intrusion normally closed contact for...

Page 7: ...iefly goes out Press as many times as the required Parameter Value To end the sequence press hold until the LED indicator lamp goes out LED Indicator lamp lit correct configuration Start Press 3 times to select the external contact Press once to accept selection Press 2 times to select the NC contact End Configuration example configuring the multicontact detector with an external contact Parameter n...

Page 8: ...nce to accept selection End Start 2 flashes confirm that the roller shutter blind contact has been correctly configured Checking configuration the contact is checked by selecting the Parameter n and then checking the number of times the indicator lamp flashes 3 2 ...

Page 9: ... characteristics Parameter vaue Built in 4 intrusion 1 prealert 2 deterrence 3 warning 4 External 5 intrusion 1 prealert 2 deterrence 3 warning 4 LED indicator lamp not lit LED indicator lamp lit about 5 sec about 10 sec about 2 sec about 10 sec To start the sequence press hold the button until the LED indicator lamp goes out Press as many times as the required Parameter number Press hold until th...

Page 10: ...e 5 Connection 1 2 3 Max loop length 10 m 5 series contacts max Connection of several types of contacts Example 1 Series wired NC contacts surface mount normally closed contacts wide gap contact piezo electric glassbreak contact shock detector etc Example 2 Series wired anti tamper NC contacts Example 3 Parallel wired NO contacts pressure mat 1 2 3 5 series contacts max Max loop length 10 m Anti t...

Page 11: ...he protected area preferably on the door frame of the entrance to be protected at least 1 m above ground level far away from any sources of interference electricity meter metallic frame etc on a flat surface IMPORTANT make sure there is a distance of at least 2 m between each product except between 2 detectors IMPORTANT when the detector is fixed to a metal support insert a 20 mm thick wooden or pl...

Page 12: ...assembly options Screw cover 1 Align the vertical slot on the magnet holder with the arrow located on the base of the detector 2 Adjust the height of the magnet holder according to the diagrams below 1 3 2 slot arrow alignment Max 5 mm 70 mm Max 5 mm Detector Magnet holder Spacers Spacer If necessary use the spacer supplied for the magnet holder or position a spacer below the normally closed detec...

Page 13: ...s Movement Contact status opening closing 23 mm 11 mm 22 mm 11 mm opening closing 34 mm 20 mm 24 mm 9 mm 24 mm 15 mm 19 mm 8 mm opening closing Spacing Vertical sliding Horizontal sliding Wooden support Soft iron support t t t t t t t t t t 3 Fix the magnet holder base place the magnet inside the cover and clip it to the base To unclip the magnet holder cover insert a small flat headed screwdriver...

Page 14: ... screw fixed Flush mounting drill a hole in the door frame and door 8 mm in diameter and 30mm deep ensure that the contact and magnet are opposite each other drill a hole in the frame for the wire to pass through yellow red green blue 1 2 3 red black 1 2 3 Cover Contact Base screwed to door frame Base screwed to door Magnet Spacers 5 mm max Surface contact Screw fixed surface mount contact Magnet f...

Page 15: ...ith a thickness of up to 6 mm Detection up to 2 5 m from the point of impact Operating temperature 18 C to 38 C Fixing method stick the sensor with double sided tape to a clean dry window cleaned with a solvent with a temperature of between 21 C and 38 C stick it in a corner of the window 2 5 mm from the edges hold it to the window for several seconds 2 5 cm 2 5 cm 2 5 cm 2 5 cm Magnet fixed to do...

Page 16: ...hen the contacts built in and external change status the radio link see on Checking the radio links described in the control panel manual beep detector X group Y immediate or delayed or combined 7 Testing IMPORTANT the control panel must be in installation mode for testing Large and small model waterproof pressure mats NO loop type Minimum weight for contact closing small model 35 kg large model 4...

Page 17: ...this period the detector automatically returns to normal operating mode about 5 sec about 10 sec about 2 sec about 10 sec 2 1 or 2 Press 2 times depending on the required parameter number Press the test 1 or 2 times to select the required parameter 1 inactive 2 active Finish the programming by pressing the test button until the led is off LED lights for 2 seconds to confirm valid programming Press...

Page 18: ...and components do not need to be accessed for operation or maintenance purposes Pressing on the button for more than 1 sec causes the control panel to give a Test message when the panel is in test or installation mode IMPORTANT If a multicontact detector monitors several entrances test each entrance in turn To test glassbreak detectors carefully tap sharply on the window using the handle of a larg...

Page 19: ... detector casing see on Opening 3 Unclip the lithium battery pack 4 Wait 2 min before replacing the flat lithium battery 5 Switch the control panel back to user mode press master code engineer installer code engineer installer code IMPORTANT the detector s configuration is saved when the battery is changed The lithium battery pack must be replaced by the same type of pack with the same technical ch...

Page 20: ...ttery life 5 years in normal conditions of use Average humidity rate 5 to 75 without condensation at 25 C Radio links TwinBand 400 800 MHz Test button battery and detection LED Indicator lamp 1 Operating temperature 10 C to 55 C Anti tamper protection against opening and removal against loop cutting Degrees of mechanical protection IP 31 IK 04 Dimensions L x W x H 138 x 26 x 30 mm Weight with batt...

Page 21: ... collection centre or the shop where you bought the product Non contractual document may be modified without prior notice DECLARATION OF CONFORMITy Manufacturer Hager Security SAS Address F 38926 Crolles Cedex France Product type Multicontact detector Trade mark Daitem We declare under our sole responsibility that the product to which this declaration relates is compliant with the essential require...

Page 22: ...805349 A 05 2013 ...

Reviews: