12
User guide
1
master code
➍
Test the alarm siren units
➎
Put the control panel back to user mode
Gradual siren
sounding
for 3 secs
(
(
(
(
(
(
(
(
(
(
Gradual siren
sounding
and strobe
for 5 secs
(
(
(
(
(
(
(
(
(
(
•
Press the OFF button on each
remote control.
or
•
Enter your master code and press the
OFF button on each keypad.
Press the Alert key on a remote control
for more than 2 seconds.
➌
Test each remote control unit
“beep, OFF,
remote control n°”
or
or
) ) ) )
) ) ) )
“beep, date,
time, OFF”
Alert
Press for more than 2 secs
REGULARLY TESTING YOUR SYSTEM: TEST MODE
➊
Switch the control panel to test mode
•
Open and then close all the
entrances protected by door and win-
dow or multicontact detectors.
•
Check the system's voice message.
➋
Test each detector
“beep, intrusion,
detector n°”
“beep, date, time,
test mode”
“beep, intrusion,
detector n°”
) ) ) ) )
) ) ) ) )
) ) ) ) )
2
Once a year or before going away for a long period, we advise you to test your security system.
The
test mode
will allow you to test each system unit.
Loud siren sounding can cause hearing problems and the necessary precautions must therefore be taken when
testing device triggering.
Before moving in front of an infrared detector, wait for 90 secs before entering the room where the detector is fitted.
master code
•
Move in front of each motion detec-
tor installed in rooms (offices, etc.).
•
Check the system’s voice message.