background image

www.daitem.com

USER GUIDE

Espace range alarm system

Summary of Contents for Espace range

Page 1: ...www daitem com USER GUIDE Espace range alarm system...

Page 2: ...and windows Switch on arm your security system If necessary check for any indications of faults or doors and windows left open When you re going to be away for a while Check that all doors and window...

Page 3: ...etwork being used become unavailable this may have consequences on the availability of its own systems Should this situation arise independent of the will of DAITEM neither DAITEM nor the manufacturer...

Page 4: ...mote control units remote keypads listen in and speak out talk back module control and information remote keypads voice keypad with tag reader hardwired control interface remote keypad uploading downl...

Page 5: ...al 2 Control keypads or interface Keypad with tag reader master code Partial 1 or Partial 2 beep armed partial 1 beep armed partial 2 group 3 group 2 Etat Syst me Partiel 2 tag presented within 3 sec...

Page 6: ...group 2 Switching off group 1 group 2 2 1 2 OFF OFF beep armed group 3 beep armed group 1 2 beep OFF group 2 beep OFF group 1 2 group OFF group armed group unchanged beep armed group ON or OFF Etat Sy...

Page 7: ...trol panel is factory configured to prevent the system from being armed when a protected entrance door fitted with a con tact sensor point is open or there is a protection mechanism fault This factory...

Page 8: ...rmed group 1 R Armed group 2 X Armed group 3 X Armed group 4 X OFF group 1 G OFF group 2 X OFF group 3 X OFF group 4 X Presence stay mode O Alarm memory Fault memory Contact open G R X R X X X G X X G...

Page 9: ...odes limit access to specific functions They are designed for occasional users Master code DISABLING or ENABLING your USER CODES The following procedures enable or disable user codes without modifying...

Page 10: ...01 to 24 Partial 1 key Master code Master code Arr t Pr sence Marche Partiel 1 Partiel 2 Alerte The user codes can provide separate restricted access to certain keypad control keys certain groups Only...

Page 11: ...y enabled To enable or disable a tag press Examples to disable tag 01 press to enable tag 02 press 1 2 0 3 8 3 2 1 0 1 0 3 8 3 2 1 3 1 1 0 3 1 0 3 8 3 2 1 3 3 0 2 0 3 2 0 3 8 3 2 1 0 3 3 In this case...

Page 12: ...Open and then close all the entrances protected by door and win dow or multicontact detectors Check the system s voice message Test each detector beep intrusion detector n beep date time test mode be...

Page 13: ...l panel responds beep armed Wait until the end of the Exit time delay the control panel announces armed After 90 secs enter a protected room the control panel and siren are triggered the telephone dia...

Page 14: ...events log reading to check the list of time and date stamped system events that have occurred You can modify your installer s uploading downloading access rights and conditions It is up to you to de...

Page 15: ...message transmitted ring dialling User site Remote monitoring company test event change to listen in mode call picked up by remote monitoring company monitoring company response frequency Procedure fo...

Page 16: ...ck your correspondents telephone numbers separately using the control panel keypad or the control interface 0 8 Master code DELETING a saved NUMBER You can delete your correspondents telephone numbers...

Page 17: ...dialler calls the number saved in the next memory if none of the correspondents stop the call cycle or they are all on the phone or not answering the complete call sequence is carried out Procedure Ac...

Page 18: ...keypad beep date time tamper remote control n Attempt to remove or open the control panel beep date time tamper control panel Attempt to remove a siren or radio repeater relay beep date time tamper s...

Page 19: ...trol n Device anti tamper mechanism failure Control panel voice message Events Loss of control panel radio link Loss of radio link between a detector and the control panel Loss of radio link between a...

Page 20: ...ion status changes automatic inhibition of contacts on doors and windows remaining open alarms faults system configuration modifications To access the events log locally using the control panel keypad...

Page 21: ...cs without receiving an order your control panel stops and terminates the transmission Pressing the key on your telephone handset unit takes you back at any time to the voice menu at the start User mo...

Page 22: ...performing device triggering tests Triggering a silent alarm if a keypad key has been programmed Control keypads or interface or Keypad with tag reader or 4 2 4 2 System status Key s for command to b...

Page 23: ...er time or winter time 1 0 5 master code Activating or de activating the chime Control interface 4 0 5 master code 2 0 5 master code Etat Syst me Partiel 2 tag presented within 3 sec after pressing be...

Page 24: ...804237 A 03 06 Non contractual document may be modified without prior notice w...

Reviews: