97
Carry out the programming sequence described below:
4. Programming
IMPORTANT: during recognition
programming, the product to be
programmed for use with the control panel
does not need to be placed next to it. In
fact, we recommend you place the product
at a short distance from the control panel
(at least 2 meters away).
IMPORTANT: the control panel indicates
there is an error by emitting 3 short beeps.
When this happens programming should
be carried out again from the start.
The universal transmitter is programmed so
that a loop is recognised by the control
panel.
If both loops are to be used, they
must both be programmed (2 steps)
.
According to the application, each loop will
be identified either as a detector or as a
control unit loop.
To programme the universal transmitter,
the
control panel must be in installation
mode
. If it is not, ask the user to press the
following sequence on the control panel
keypad:
then :
master code
engineer installer
code
4.1 Loop n° 1 programming
5.
The control panel
confirms
programming by
issuing a voice
message
)
)
)
10 sec. max.
2.
Press &
hold the
“Test”
button until
the control
panel
responds
(see (1) on
next page)
3.
The control panel
waits for a
group
to be chosen
from
1 to 8
*. Press the
corresponding
digits on the
control panel
keypad to choose
the group
2.
Press & hold the
“Test”
button until the control
panel responds
3.
The control panel confirms
programming by issuing a
voice message
4.
The control panel
waits for the time
delay to be chosen:
0: immediate
1: delayed,
2: combined.
Press
“0” or “1” on the
control panel keypad
to choose the group
)
)
)
10 sec. max.
or
(depending on configuration)
de
tec
to
r
con
tro
l un
it
1.
Press
*
then
#
on
the control panel
keypad to move to
programming mode
then
* according
to the model of
the control panel
“beep, detector X,
group Y, immediate
(or delayed
or combined)”
“beep, remote control X”
“detector X”
to
“time delay?”
“group?”
to
*
Summary of Contents for 221-21 Series
Page 111: ...111 ...