background image

6

5.3 Directing and testing the detector

IMPORTANT: the control panel must be in installation mode to check the above.

IMPORTANT: at the end of the test period, the detector automatically switches back to normal operating mode: 
• detector inhibited for 90 sec. after detection,
• the test LED indicator lamp is no longer lit when movement is detected.

The infrared detector has a test mode for
checking:

• the power supply:

the LED indicator lamp

lights up when you press the test button to
confirm the battery is operating correctly,

• the detection area: 

the LED indicator lamp

lights up on detection,

• the radio link

(see § on checking the radio

link in the control panel manual).

)

)

)

)

)

Checking the detection area:

• press on the test button: the detector switches to test mode for a period

of 90 sec.,

• walk across the detection area at right angles to the detector’s fields-of-

view (see diagram): every time movement is detected the detector test
LED indicator lamp lights up.

If no movement is detected: change the way the detector is facing on its
swivel bracket, check there is no obstacle between the detection area and
the detector.

“beep, detector X,

group Y immediate 

(or delayed

or combined)”

Pozidriv 1

Pozidriv 1

IMPORTANT: when fixing the movement detector at an angle or flat against the
wall, fix the label (provided in the sachet of accessories) on the reverse side of the
product in order to cover the opening to avoid insects getting through.

Si fixation en angle ou à plat contre un mur

For a fixing in a corner or flat against the wall 

Si fixation en angle ou à plat contre un mur  
For a fixing in a corner or flat against the wall

1

653563_A

2

• Fixing the detector flat against the wall

1. 

Drill through the two pre-drilling holes in the base of the motion detector.

2.

Place the base against the wall in the desired place in order to mark
where to drill the holes (a picture of a man indicates the top of the base).

3.

Drill the holes in the wall and fix the base.

4.

Remove the factory-positioned pin.

5.

Detach pin 

n° 1

from the selection supplied.

6.

Position the pin in the right place.

7.

Place the motion detector on its base.

• Fixing the detector in a corner

1. 

Drill through the two pre-drilling holes in the base of the detector.

2.

Place the base against the wall in the desired place in order to mark
where to drill the holes (a picture of a man indicates the top of the base).

3.

Drill the holes in the wall and fix the base.

4.

Remove the factory-positioned pin.

5.

Detach pin 

n° 2

from the selection supplied.

6.

Position the pin in the right place.

7.

Place the motion detector on its base.

2 fixing
screws

Pre-drilled holes

Pictogram

Pictogram

2 fixing
screws

Pre-drilled holes

90°

Pin 

n° 2

for fixing 

the detector 
in a corner

171-21X 
175-21X

172-21X
173-21X

Pin 

n° 1

for fixing

the detector flat
against the wall

Summary of Contents for 171-21X

Page 1: ......

Page 2: ...0 5 10 15 20 22 1 1 0 1 2 3 4 5 6 7 8 9 10 11 12 1 2 m 171 21X 175 21X motion detector 19 fields of view 12 m 90 is designed to protect rooms at risk lounge main bedroom etc 172 21X corridor detector...

Page 3: ...pad Press and hold the test button until the control panel responds The control panel waits for a group to be chosen from 1 to 8 Choose the group by pressing the corresponding numeral on the control p...

Page 4: ...ntrusion factory setting 2 Prealert 3 Deterrence 4 Warning Freeze detection 7 1 Disabled factory setting setting 3 Enabled Configuration example setting the detector for an alarm level when a full pre...

Page 5: ...r lamp flashes continuously when the detector is fitted to its bracket The detector can be fixed to a wall in 3 ways on a swivel bracket flat against the wall in a corner There is an anti tamper pin f...

Page 6: ...ed in the sachet of accessories on the reverse side of the product in order to cover the opening to avoid insects getting through Si fixation en angle ou plat contre un mur For a fixing in a corner or...

Page 7: ...ications Infrared motion detector Infrared detection 171 21X 175 21X 12 m 90 motion detector 172 21X 22 m 12 corridor detector 173 21X 12 m 8 curtain detector Fixing methods on a swivel bracket flat a...

Page 8: ...ial requirements of the following European Directives R TTE Directive 99 5 CE Low Voltage Directive 2006 95 CE ROHS Directive 2002 95 CE in compliance with the following harmonised European Standards...

Reviews: