background image

2

2. Preparation

2.1 Opening

2.2 Power supply

Open the detector casing by loosening
the screws using a cross-head
screwdriver.

Connect the lithium battery pack according to the arrow.

Test button

Test LED
indicator
lamp behind
lens

Detection
lens

Locking screw

The infrared detector is used for protection inside buildings. Intruders are detected when the infrared radiation associated
with movement varies. The detector also detects freezing temperatures based on a thermostatic principle (a technical alarm
is triggered when the temperature drops below 5°C).

1. Introduction

0

2

4

6

8 10 12 

2,2m

16  18  20  22 

14

1

0 1 2 3 4 5 6 7 8

9 10 11 12

2,2m

1

0

5

10

15

2

2

0

5

10

15

20

22

1

1

0

1

2

3

4

5

6

7

8

9

10 11 12

1

2 m

• 171-21X/175-21X:

motion detector

(19 fields-of-view, 12 m, 90°) is
designed to protect rooms at risk
(lounge, main bedroom, etc.).

• 172-21X: 

corridor detector (9 fields-

of-view, 22 m, 12°) is designed for
unavoidable passageways, and can
be placed facing the entry point to
be protected.

• 173-21X:

curtain detector (9 fields-

of-view, 12 m, 8°) is designed for the
protection of large surfaces (plate
glass windows, garage doors, etc.).

0

2

4

6

8

10 12 m

2,20

12 m

4

8

0

detection zone 
(1

st

interruption)

detection zone
(2

nd

interruption)

Alignment arrow

Removable tab

Guarantee sticker

Remove the pre-cut part of the sticker
and stick it to the guarantee certificate in
the user manual supplied with the control
panel. If you are adding the siren to an
existing system, use the guarantee
sticker provided with this product.

171-21X

171-21X

Summary of Contents for 171-21X

Page 1: ......

Page 2: ...0 5 10 15 20 22 1 1 0 1 2 3 4 5 6 7 8 9 10 11 12 1 2 m 171 21X 175 21X motion detector 19 fields of view 12 m 90 is designed to protect rooms at risk lounge main bedroom etc 172 21X corridor detector...

Page 3: ...pad Press and hold the test button until the control panel responds The control panel waits for a group to be chosen from 1 to 8 Choose the group by pressing the corresponding numeral on the control p...

Page 4: ...ntrusion factory setting 2 Prealert 3 Deterrence 4 Warning Freeze detection 7 1 Disabled factory setting setting 3 Enabled Configuration example setting the detector for an alarm level when a full pre...

Page 5: ...r lamp flashes continuously when the detector is fitted to its bracket The detector can be fixed to a wall in 3 ways on a swivel bracket flat against the wall in a corner There is an anti tamper pin f...

Page 6: ...ed in the sachet of accessories on the reverse side of the product in order to cover the opening to avoid insects getting through Si fixation en angle ou plat contre un mur For a fixing in a corner or...

Page 7: ...ications Infrared motion detector Infrared detection 171 21X 175 21X 12 m 90 motion detector 172 21X 22 m 12 corridor detector 173 21X 12 m 8 curtain detector Fixing methods on a swivel bracket flat a...

Page 8: ...ial requirements of the following European Directives R TTE Directive 99 5 CE Low Voltage Directive 2006 95 CE ROHS Directive 2002 95 CE in compliance with the following harmonised European Standards...

Reviews: