3. Programming

IMPORTANT: during recognition programming, the product to be programmed for use with the control panel does not need to
be placed next to it. In fact, we recommend you place the product at a short distance from the control panel (at least 2 meters
away).

Programming enables the detector to be recognised by the control panel.

2. 

Programme the device as follows:

1. 

To programme the detector the control panel must be in installation mode. If it is not, ask the user to press:

then    

“beep, installation

mode”

IMPORTANT: the control panel indicates there is an error by emitting 3 short beeps. When this happens programming
should be carried out again.

Press 

*

then 

#

on

the control panel
keypad

Press and hold the 

“test”

button until the control
panel responds 

The control panel waits 
for a 

group

to be chosen

(from 1 to 8)*

. Choose the

group by pressing the
corresponding numeral on the 
control panel keypad

Choose the type of triggering: 

0: immediate
1: delayed
2: combined

Use the control panel keypad 
to select the type

The control panel
gives a voice
message to confirm

then

to

)

)

)

)

)

10 s max.

“detector X”

“group?”

“time delay?”

*

to

* according to the

type of control panel

master code 
(0000 by default)

engineer installer code 
(1111 by default)

“beep, detector X,

group Y immediate 

(or delayed

or combined)”

• Example: programming of 1st detector allocated to Gr. 2 with immediate triggering.

“beep, detector

1, group 2,

immediate” 

)

)

)

)

)

10 s max.

“detector 1”

“group?”

“time delay?”

then

IMPORTANT: the control panel indicates
there is an error by emitting 3 short
beeps. When this happens programming
should be carried out again.

Summary of Contents for 171-21X

Page 1: ......

Page 2: ...0 5 10 15 20 22 1 1 0 1 2 3 4 5 6 7 8 9 10 11 12 1 2 m 171 21X 175 21X motion detector 19 fields of view 12 m 90 is designed to protect rooms at risk lounge main bedroom etc 172 21X corridor detector...

Page 3: ...pad Press and hold the test button until the control panel responds The control panel waits for a group to be chosen from 1 to 8 Choose the group by pressing the corresponding numeral on the control p...

Page 4: ...ntrusion factory setting 2 Prealert 3 Deterrence 4 Warning Freeze detection 7 1 Disabled factory setting setting 3 Enabled Configuration example setting the detector for an alarm level when a full pre...

Page 5: ...r lamp flashes continuously when the detector is fitted to its bracket The detector can be fixed to a wall in 3 ways on a swivel bracket flat against the wall in a corner There is an anti tamper pin f...

Page 6: ...ed in the sachet of accessories on the reverse side of the product in order to cover the opening to avoid insects getting through Si fixation en angle ou plat contre un mur For a fixing in a corner or...

Page 7: ...ications Infrared motion detector Infrared detection 171 21X 175 21X 12 m 90 motion detector 172 21X 22 m 12 corridor detector 173 21X 12 m 8 curtain detector Fixing methods on a swivel bracket flat a...

Page 8: ...ial requirements of the following European Directives R TTE Directive 99 5 CE Low Voltage Directive 2006 95 CE ROHS Directive 2002 95 CE in compliance with the following harmonised European Standards...