background image

Model 9016 X-Purge Operator Interface 

 

Daisy Data Displays, Inc. 

February 2022 

15 

D010-000002 

8

 

Trouble-Shooting Guide 

8.1

 

Division 1 X-Purge Trouble-Shooting 

PROBLEM 

POSSIBLE CAUSE 

SUGGESTED SOLUTION 

When power is applied, the 

purge status indicator light 

does not come on 

Power is not connected to 

the unit 

Connect AC power to the power 

connection on the purge system. 

Ensure that the power switch is on. 

Ensure that AC power is on. 

Improper line voltage 

selection 

Ensure that the 120/240 VAC switch 

on the purge control is set 

appropriately for your power 

source. 

After power is applied, the 

purge status indicator stays 

solid red; it does not switch to 

yellow or blink 

No air supply to unit 

Ensure that a purge gas line is 

connected to the unit and that the 

supply line is “on.” The pressure 

gauge on the air-in box should 

indicate a higher pressure than 20 

PSI 

Restrictions in air line 

Ensure that supply line and inlet 

connect have no restrictions and 

that the supply line is not kinked 

Restrictions in main purge 

line inside enclosure 

Ensure that the main purge line 

(terminating in a brass tee fitting) is 

not kinked or disconnected 

Leaks in the enclosure 

Ensure that all access doors are 

closed and latched. Ensure that all 

access panels are closed and sealed. 

There should be no holes or 

openings in the enclosure. 

The purge status indicator is 

yellow, but the enclosure 

takes an excessively long time 

to complete the purge (when 

the status indicator turns 

green) 

Low purge gas supply 

pressure 

Increase purge gas inlet pressure at 

the air-in regulator or on the main 

supply line 

Restriction in the main purge 

line 

Ensure that the main purge line 

within the enclosure (ending in a 

brass tee fitting) is not kinked or 

obstructed 

Purge status indicator flashes 

yellow and purge takes an 

excessively long time to 

complete. 

Low purge gas supply 

pressure 

Increase purge gas inlet pressure at 

the air-in regulator or on the main 

supply line 

Purge or operation stops and 

purge status indicator flashes 

red code 

Fatal purge error 

See Table 6.1 X-Purge Status Light 

Key on page 12. 

 

Summary of Contents for 9016 X-Purge

Page 1: ...February 2022 D010 000002 Model 9016 X Purge User Manual...

Page 2: ...te radio frequency energy and if not installed and used in accordance with the instructions in this manual may cause interference to radio communications Such equipment has been tested and found to co...

Page 3: ...articular purpose or other warranty of quality whether expressed or implied except of title and against patent infringement Correction of nonconformities in the manner and for the period of time provi...

Page 4: ...d conduit entry 9016 15 18 enclosures 19 P008 X Purge front panel item location 20 P011 Cable and conduit entry 9016 mounted to enclosure 21 E030 Electrical input connections 22 M015 9016 X Purge dime...

Page 5: ...Division 1 hazardous areas The installation of an X Purge system on an enclosure in a Division 1 area renders the area within the enclosure to an essentially non rated environment Thus normally rated...

Page 6: ...ne see drawing P007 3 INPORTANT Bleed the pressurized purge air or inert gas line ensuring that any dirt moisture and contaminants are cleared from the line before connecting the pressurized purge air...

Page 7: ...This change may vary slightly on some units if in later testing the unit fails with an 3 2 over flow error code decrease the inlet pressure by another 2 PSI Note Pressure for use during start up 13 Re...

Page 8: ...dry location at 70 F Any equipment accidentally splashed with sealing compound should be cleaned with soap and water before the sealing compound cures Equipment Required Four PAC Seal fittings 1 NPT...

Page 9: ...f the sealing compound when the powder is mixed with water is approximately 30 minutes at 70 F If accelerated curing is desired low temperature oven drying at 180 F can be used Do not expose the seali...

Page 10: ...t gas line see drawing P011 3 Bleed the purge air or inert gas line to ensure that dirt moisture and other contaminants are cleared from the line prior to connecting the line to the unit 4 Connect the...

Page 11: ...pleted successfully and the same results were seen up to this point in the procedure you may skip the remaining steps of this procedure If not continue to Step Error Reference source not found 7 Slowl...

Page 12: ...uire the purge system be SHUT DOWN before correcting the problem and restarting the purge cycle Table 6 1 X Purge Status Light Key Color Code Meaning Status Recommended Action Green 0 Operate purge co...

Page 13: ...ooting Section page 15 Red 4 2 Faulty flow sensor Fatal Purge System component failure Contact DAISY Customer Service See Section 7 Review Customer Service on page 14 Red 4 3 Short purge switch is stu...

Page 14: ...ntact Daisy s Customer Service Department Equipment returned to DAISY for service must be accompanied by a valid Return Merchandise Authorization RMA number Anything shipped to DAISY without a valid R...

Page 15: ...restrictions and that the supply line is not kinked Restrictions in main purge line inside enclosure Ensure that the main purge line terminating in a brass tee fitting is not kinked or disconnected Le...

Page 16: ...th W 5 0 Depth D 5 lbs ENVIRONMENTAL Operating Temperature 32 122 F Storage Temperature 32 158 F Relative Humidity 10 95 Non condensing ELECTRICAL Power Usage 5 watts maximum Switching Capacity power...

Page 17: ...rge front panel item location 26 P013 X Purge back panel item location 27 P014 Stand alone X Purge pneumatic block diagram 28 E028 Stand alone X Purged electrical block diagram 29 E017 Power interface...

Page 18: ...Model 9016 X Purge Operator Interface Daisy Data Displays Inc February 2022 18 D010 000002 THIS PAGE INTENTIONALLY BLANK...

Page 19: ...Page 19...

Page 20: ...Page 20...

Page 21: ...Page 21...

Page 22: ...Page 22...

Page 23: ...Page 23...

Page 24: ...Page 24...

Page 25: ...Page 25...

Page 26: ...Page 26...

Page 27: ...Page 27...

Page 28: ...Page 28...

Page 29: ...Page 29...

Page 30: ...Page 30...

Page 31: ...3 10 WHITE BLUE 10 3 J9 3 3 4 9 BLUE WHITE 9 4 J9 4 4 5 8 WHITE GREEN 8 5 J9 5 5 6 7 GREEN WHITE 7 6 J9 6 6 7 6 WHITE ORANGE 6 7 J9 7 7 8 5 ORANGE WHITE 5 8 J9 8 8 9 4 ORANGE RED 4 9 J9 9 9 10 3 RED O...

Page 32: ......

Page 33: ......

Page 34: ...Page 34...

Page 35: ...Page 35...

Page 36: ...Page 36...

Page 37: ...Page 37...

Page 38: ...Page 38...

Page 39: ...Page 39...

Reviews: