Technical data
Model
DSP
‐
85HA
DSP
‐
100HA
DSP
‐
120HA
Heating Capacity
(
kW
)
8.5
10
12
COP 5.02
4.95
4.92
Cooling Capacity
(
kW
)
6.2 8.3 9
EER 3.59
3.59
3.6
Rated Input
(
kW
)
1.69 2.02 2.44
Rated Current
(
A
)
7.7 9.2 11.1
Max Current
(
A
)
12.4 14.5 18.7
Power Supply(V/Ph/Hz)
220
‐
240/1/50
Setting Temp. Range
15
℃~
45
℃
Running Temp. Range
‐
5
℃~
43
℃
Unit Dimension (W×H×D,mm)
615×1060×370
Net Weight
(
KG
)
55 62 70
Noise dB(A)
52
54
54
Water Inlet/Outlet Dimension
50.8(2
″
)
Water Heat Exchanger
Titanium
Min. Water Flow
(
L/MIN
)
60
72
80
Refrigerant R410A
Display LCD
Mode Heating/Cooling/AUTO
NOTES
:
Capacities and power inputs based on the following conditions:
-
Heating: Outlet water temperature 27
℃
.Ambient air temperature 20
℃
(DB)/19
℃
(WB)
-
Cooling: Outlet water temperature 27
℃
.Ambient air temperature 35
℃
(DB)/27
℃
(WB)
Note: The above data might change as the product improves; please refer to the details on the