- 12 -
◆
Up / Down
Up / Down buttons are used to raise or reduce set water temperature, adjust the time of the
clock and the timer, reset part of parameter in the management level
The outlet water temp adjustment range from 25
℃
~60
℃
;
◆
Off timer / On timer
Press these two buttons to adjust timer.
When at the heating mode or shut down, press the timer on button for more than tem 10
seconds, the system will enter into defrosting mode forcibly and the words “defrosting” will be
shown on the screen; press “ON / OFF” to quit defrosting mode compulsively.
Note: the unit is of defrosting automatic function, so only when defrosting incompletely in
winter is the compulsively defrosting needed. This operation must be forbidden usually.
◆
Mode
Press this button to change heating/cooling mode.
◆
Inquiry
Press this button to inquire temperature of each detector; or adjust and reset some parameters
of the unit license
Press the “Inquiry” button, entering into the parameter checking mode
Item
Code
Water outlet temp
d01
Water back temp
d02
Outer ambient temp
d03
Outer coil 1 temp
d04
Compressor back 1 temp
d06
Input state
d08
Compressor stop unrecoverable fault code
d09
Compressor stop restorable fault code
d10