Safety Precautions 

       

 

 

 

 

General 

 

  Make sure that the fixed ground wire in the building is securely connected to earth.   

  Wiring tasks should be carried out by qualified electricians only, in addition, they should 

check the safety conditions of power utilization, for example, check if the cable capacity is 

adequate, and check if the power cable is damaged.   

  Home users must not install, repair or relocate the unit.   

Improper treatment might lead to the accidents e.g. personal injury caused by fire, electrical 

shock or unit's falling

off, and water leakage in the machine. Please contact professionals for 

repair. 

  The unit shall not be installed at a spot with potential hazard of leakage of inflammable gas.   

In case the leaked gas is congregated around the machine, there might be the risk of explosion.   

  Make sure that the foundation of installation is stable. 

If the foundation is unstable, the outdoor unit may drop and cause a casualty.   

  Make sure that the electric leakage protection switch is fixed.   

If no electric leakage protection switch is fixed at the beginning of the electric supply, it maybe 

cause electric shocks or fires.   

If any abnormity occurs in the unit (such as burned smell inside the unit), cut off the power 

supply immediately, and contact professionals for repair.   

 

Please follow the instruction below when cleaning the unit. 

a. Before cleaning, cut off the electric supply of the unit firstly to avoid injuries caused by fan in 

operation. 

b. Do not rinse the unit by water because the rinsed unit may cause electric shock. 

  Make sure to cut off the electric supply before maintaining the unit.   

  Please do not insert fingers or sticks into air outlet or air inlet.   

Note! 

 

It is required to read the Safety precautions in details before 

operation. The precautions listed below are all-important for 

safety. Please follow the instructions strictly.

 

Summary of Contents for DSP? 85HA

Page 1: ...Air Source Swimming pool Heat Pump Installation and Operation Manual DSP 85HA DSP 100HA DSP 120HA...

Page 2: ...1 Content Safety Precautions 2 Technical data 3 Unit dimension 4 Installation 5 Sound pressure level 8 Electric connection 9 Controller instruction 11 Maintenance Troubleshooting 15...

Page 3: ...n of installation is stable If the foundation is unstable the outdoor unit may drop and cause a casualty Make sure that the electric leakage protection switch is fixed If no electric leakage protectio...

Page 4: ...nning Temp Range 5 43 Unit Dimension W H D mm 615 1060 370 Net Weight KG 55 62 70 Noise dB A 52 54 54 Water Inlet Outlet Dimension 50 8 2 Water Heat Exchanger Titanium Min Water Flow L MIN 60 72 80 Re...

Page 5: ...4 Unit dimensions Model A mm B mm C mm D mm E mm DSP 85 HA DSP 100 HA DSP 120HA 650 1140 415 435 684...

Page 6: ...al safety 4 Ensure the unit is well ventilated direction of air exhaust is kept away from windows of neighboring buildings and the exhaust air cannot flow back Moreover adequate service clearance shou...

Page 7: ...6 Installation in exceptional circumstances unit mm No obstacle in front of the unit Obstacle above the unit Obstacle in front of the unit Several units in a row...

Page 8: ...7 Installation diagram Installation diagram for combination...

Page 9: ...d a place on the side that faces the least sound sensitive neighbor area The sound pressure levels are further affected by walls bricks differences in ground level etc and should therefore only be see...

Page 10: ...er with at least a 3 mm breaking gap Incoming supply must be 220V 1 phase neutral ground via a distribution board with fuses If an insulation test is to be carried out in the building please make sure...

Page 11: ...10 Circuit drawing...

Page 12: ...me When the timer on timer off are set press this button the unit will start or stop according to the set time everyday Press again to cancel it Time Press time button it shows clock Press up or down...

Page 13: ...FF to quit defrosting mode compulsively Note the unit is of defrosting automatic function so only when defrosting incompletely in winter is the compulsively defrosting needed This operation must be fo...

Page 14: ...ting end temp adjustment 2 25 12 P07 Defrosting interval time adjustment 20 80 min 45min P08 Defrosting running time adjustment 3 15 min 6min P09 Compressor exhaust protection temp adjustment 100 125...

Page 15: ...0 No 1 Yes 1 P54 Function selecting of exhaust temp protection 0 No 1 Yes 1 P55 Water flow switch 0 No 1 Yes 1 P56 Water pump open constantly option 1 open constantly 0 open close normally 1 Adjust th...

Page 16: ...ating exchanger regularly to maintain good heat exchange as conserve energy The operation pressure of the refrigerant system should only be serviced by a certified technician Check the power supply an...

Page 17: ...07 Outlet water temp E09 Water flow insufficient E10 Communication failure E14 Compressor exhaust temp E25 Outlet water overcooling protection in the cooling mode E26 Outlet water overheating protecti...