Daishiba DSP?45HCA User Manual Download Page 21

Swimming pool heat pump 

 

- 20 - 

P1 or d 

System pipe temp 

-9~90

 

 

Measured 

value 

P2 or E 

Reservation

 

-9~90

 

 

Reservation

 

ROOM or F 

Ambient temp 

-9~90

 

 

Measured 

value

 

 

Parameter table (LCD or LED) 

Protection / Fault 

Remote 
controller 

Host unit running /   

Fault indicator light 

Standby   

 

Extinguish 

Normal starting up 

 

Bright 

Water inlet temp. sensor fault 

PP 01 or PP 1 

☆●

(1 Flash and 1 Extinguish) 

Water outlet temp. sensor fault 

PP 02 or PP 2 

☆☆●

(2 Flash and 1 Extinguish) 

Coil temp. sensor fault 

PP 03 or PP 3 

☆☆☆●

(3 Flash and 1 Extinguish) 

Ambient temp. sensor fault 

PP 05 or PP 5 

☆☆☆☆☆●

(5 Flash and 1 Extinguish) 

Water  inlet  and  outlet  oversize 
temp. difference protection 

PP 06 or PP 6 

Bright

 

Cooling anti-freezing protection 

PP 07 or PP 7 

Bright

 

Winter  first  grade  anti-freezing 
protection 

PP 07 or PP 7 

Extinguish 

Winter  second  grade  anti-freezing 
protection 

PP 07 or PP 7 

Extinguish 

High pressure protection 

EE 01 or EE 1 

☆☆☆☆☆☆●

(6 Flash and 1 Extinguish) 

Low pressure protection 

EE 02 or EE 2 

☆☆☆☆☆☆☆●

(7 Flash and 1 Extinguish) 

Water flow fault 

EE 03 or EE 3 

(8  Flash  and  1 

Extinguish) 

Water  inlet  and  outlet  oversize 
temp. difference fault 

EE 05 or EE 5 

☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ☆ ●

(10  Flash  and  1 

Extinguish) 

Defrosting 

Defrosting 
indication 

☆☆☆☆☆☆☆☆……

(Flash all the time) 

Communication fault 

EE 08 or EE 8 

(This fault is only valid remote controller) 

 
Note:     

It will exit automatically without any operation within 8s. 

Please don’t change system parameter freely, or else it may affect the normal running state. 

 
 

 

Summary of Contents for DSP?45HCA

Page 1: ...Air Source Swimming Pool Heat Pump USER MANUAL DSP 45HCA DSP 65HCA DSP 85HCA DSP 100HCA DSP 120HCA DSP 180HCA DSP 180HCA 3 DSP 230HCA DSP 230HCA 3 DSP 260HCA 3...

Page 2: ...p when running It may touch the fan and damage it or lead to accidents especially for the children Do not use the unit without the grid in case it may lead to any accidents 6 For safety reasons please...

Page 3: ...Swimming pool heat pump 2 Content Product brief instruction 3 Technical data 4 Unit dimension 6 Installation 8 Electric connection 13 Controller operation instruction 16 Maintenance Troubleshooting 22...

Page 4: ...l water Your existing water pump circulates the water through the heat pumps heater usually next to the pool equipment and the water warms up This pool heat pump is also of cooling function User can c...

Page 5: ...220 240 1 50 Setting Temp Range 15 45 Running Temp Range 5 43 Water Inlet Outlet Dimension 50 8mm Water Heat Exchanger Titanium Water Flow m3 h 3 4 4 4 5 4 5 Refrigerant R410A Unit Dimension W H D mm...

Page 6: ...Temp Range 5 43 Water Inlet Outlet Dimension 50 8mm Water Heat Exchanger Titanium Water Flow m3 h 7 5 8 5 Refrigerant R410A Unit Dimension W H D mm 820X720X1055 Net Weight KG 119 119 133 133 148 Disp...

Page 7: ...ol heat pump 6 UNIT DIMENSIONS Horizontal models Model A mm B mm C mm D mm E mm DSP 45 HCA 510 306 266 276 410 DSP 65 85 HCA 552 995 284 344 680 DSP 100 HCA 617 1118 350 290 660 DSP 120 HCA 650 1140 4...

Page 8: ...Swimming pool heat pump 7 Vertical models DSP 180HCA DSP 180HCA 3 DSP 230HCA DSP 230HCA 3 DSP 260HCA 3...

Page 9: ...installed on the floor its undercarriage should be heightened to avoid ingression of accumulated water in rainy season In snowy areas it is important to prevent accumulated snow from blocking up the a...

Page 10: ...led anywhere outdoors providing minimum distance requirements are met with respect to other objects For indoor pools please consult your installer Attention Do not place the unit in an enclosed area w...

Page 11: ...hould be avoided as much as possible as machine falling down may result in severe accident Distance from the pool Normally the pool heat pump is installed within a 7 5 meter radius of the swimming poo...

Page 12: ...be lower than the unit standard value please refer to the nameplate 2 The insulation of water pipe should be done well to prevent energy loss 3 A suitable draining valve should be installed in the bot...

Page 13: ...Swimming pool heat pump 12 Project Installation sketch map...

Page 14: ...e neutral ground via a distribution board with fuses If an insulation test is to be carried out in the building please make sure to disconnect the heat pump To avoid the possibility of false action ca...

Page 15: ...Swimming pool heat pump 14 Circuit diagram Model DSP 45HCA DSP 65HCA DSP 85HCA DSP 100HCA DSP 120HCA...

Page 16: ...Swimming pool heat pump 15 Model DSP 180HCA 3 DSP 230HCA 3 DSP 260HCA 3...

Page 17: ...ON or OFF at any state At the ON state press the key into OFF state it shows Clock Working mode and Timer status At the OFF state press the key to start unit it shows Water inlet temp Working mode and...

Page 18: ...quiry interface of parameter and state it exits inquiry interface to enter into main interface if there is no any operation for 8 seconds 1 3 System parameter setting 1 3 1 At inquiry interface if it...

Page 19: ...election parameter 0 Only cold 1 Heat pump 2 E heater 3 Only heat 1 Adjustable 09 Water pump working Mode 0 Normal 1 Special 0 Adjustable 10 Automatic return water temp setting value 8 60 40 Adjustabl...

Page 20: ...is only valid remote controller Parameter table LCD or LED Parameter Meaning Range Default Remark 00 or 0 Cooling return water temp setting value 8 28 12 Adjustable 01 or 1 Heating return water temp...

Page 21: ...mp difference protection PP 06 or PP 6 Bright Cooling anti freezing protection PP 07 or PP 7 Bright Winter first grade anti freezing protection PP 07 or PP 7 Extinguish Winter second grade anti freezi...

Page 22: ...does not occur Discharge the water at the bottom of water pump if the unit will not be used for an extended period of time Check the unit thoroughly and fill the system with water fully before using...

Page 23: ...ire 4 Replace it with new high pressure switch 5 It is done by professionals EE 02 or EE 2 Low pressure protection 1 Check the connecting wire 2 Check if low pressure switch is broken 3 Check if lack...

Page 24: ...DAISHIBA Heating Refrigeration Equipment Co Ltd Web www daishiba com cn Tel 86 757 85213698 Fax 86 757 85213699 Email jenny daishiba com cn Add No 2 Chuangye Nan Road Songxia Industrial Park Songgang...

Reviews: