Daishiba DSP?45HCA User Manual Download Page 19

Swimming pool heat pump 

 

- 18 - 

 

Parameter table (1100-3502 A

B type Swimming Pool Heat Pump LCD Controller) 

Parameter

 

Meaning 

Range 

Default 

Remark 

00 

Cooling return water temp 

setting value 

8~28

 

12

 

Adjustable 

01 

Heating return water temp 

setting value 

15~40

 

40

 

Adjustable 

02 

Heating Defrosting period   

30~90Min 

40Min 

Adjustable 

03 

Enter Heating Defrosting 

Temperature spots 

-30~0

 

-7

 

Adjustable 

04 

Exit Heating Defrosting 
Temperature condition 

2~30

 

13

 

Adjustable 

05 

Exit Heating Defrosting Time 

condition 

1-12Min 

8Min 

Adjustable 

06 

System quantity 

1/2 

Invalid   

07 

Power failure protection 

0(No) /1(Yes) 

Adjustable 

08 

Model Selection parameter 

0(Only cold) /1(Heat pump) 

/2(E-heater) /3(Only heat)   

Adjustable   

09 

Water pump working Mode 

0(Normal) /1(Special) 

Adjustable 

10 

Automatic return water temp 

setting value 

8~60

 

40

 

Adjustable 

 

System state (1100-3502 A

B type Swimming Pool Heat Pump LCD Controller) 

Code 

Meaning 

Display range 

Remark 

IN 

Water inlet 

temp 

-9~90

 

Measured value 

OUT 

Water outlet 

temp 

-9~90

 

Measured value 

P1 

System pipe 

temp 

-9~90

 

Measured value 

P2 

Reservation 

-9~90

 

Reservation 

ROOM 

Ambient temp 

-9~90

 

Measured value 

 

System fault (1100-3502 A

B type Swimming Pool Heat Pump LCD Controller) 

Protection / Fault 

Remote 
controller 

Host unit running /   

Fault indicator light 

Standby   

 

Extinguish 

Normal starting up 

 

Bright 

Water inlet temp. sensor fault 

PP 01 

☆●

(1 Flash and 1 Extinguish) 

Water outlet temp. sensor fault 

PP 02 

☆☆●

(2 Flash and 1 Extinguish) 

Summary of Contents for DSP?45HCA

Page 1: ...Air Source Swimming Pool Heat Pump USER MANUAL DSP 45HCA DSP 65HCA DSP 85HCA DSP 100HCA DSP 120HCA DSP 180HCA DSP 180HCA 3 DSP 230HCA DSP 230HCA 3 DSP 260HCA 3...

Page 2: ...p when running It may touch the fan and damage it or lead to accidents especially for the children Do not use the unit without the grid in case it may lead to any accidents 6 For safety reasons please...

Page 3: ...Swimming pool heat pump 2 Content Product brief instruction 3 Technical data 4 Unit dimension 6 Installation 8 Electric connection 13 Controller operation instruction 16 Maintenance Troubleshooting 22...

Page 4: ...l water Your existing water pump circulates the water through the heat pumps heater usually next to the pool equipment and the water warms up This pool heat pump is also of cooling function User can c...

Page 5: ...220 240 1 50 Setting Temp Range 15 45 Running Temp Range 5 43 Water Inlet Outlet Dimension 50 8mm Water Heat Exchanger Titanium Water Flow m3 h 3 4 4 4 5 4 5 Refrigerant R410A Unit Dimension W H D mm...

Page 6: ...Temp Range 5 43 Water Inlet Outlet Dimension 50 8mm Water Heat Exchanger Titanium Water Flow m3 h 7 5 8 5 Refrigerant R410A Unit Dimension W H D mm 820X720X1055 Net Weight KG 119 119 133 133 148 Disp...

Page 7: ...ol heat pump 6 UNIT DIMENSIONS Horizontal models Model A mm B mm C mm D mm E mm DSP 45 HCA 510 306 266 276 410 DSP 65 85 HCA 552 995 284 344 680 DSP 100 HCA 617 1118 350 290 660 DSP 120 HCA 650 1140 4...

Page 8: ...Swimming pool heat pump 7 Vertical models DSP 180HCA DSP 180HCA 3 DSP 230HCA DSP 230HCA 3 DSP 260HCA 3...

Page 9: ...installed on the floor its undercarriage should be heightened to avoid ingression of accumulated water in rainy season In snowy areas it is important to prevent accumulated snow from blocking up the a...

Page 10: ...led anywhere outdoors providing minimum distance requirements are met with respect to other objects For indoor pools please consult your installer Attention Do not place the unit in an enclosed area w...

Page 11: ...hould be avoided as much as possible as machine falling down may result in severe accident Distance from the pool Normally the pool heat pump is installed within a 7 5 meter radius of the swimming poo...

Page 12: ...be lower than the unit standard value please refer to the nameplate 2 The insulation of water pipe should be done well to prevent energy loss 3 A suitable draining valve should be installed in the bot...

Page 13: ...Swimming pool heat pump 12 Project Installation sketch map...

Page 14: ...e neutral ground via a distribution board with fuses If an insulation test is to be carried out in the building please make sure to disconnect the heat pump To avoid the possibility of false action ca...

Page 15: ...Swimming pool heat pump 14 Circuit diagram Model DSP 45HCA DSP 65HCA DSP 85HCA DSP 100HCA DSP 120HCA...

Page 16: ...Swimming pool heat pump 15 Model DSP 180HCA 3 DSP 230HCA 3 DSP 260HCA 3...

Page 17: ...ON or OFF at any state At the ON state press the key into OFF state it shows Clock Working mode and Timer status At the OFF state press the key to start unit it shows Water inlet temp Working mode and...

Page 18: ...quiry interface of parameter and state it exits inquiry interface to enter into main interface if there is no any operation for 8 seconds 1 3 System parameter setting 1 3 1 At inquiry interface if it...

Page 19: ...election parameter 0 Only cold 1 Heat pump 2 E heater 3 Only heat 1 Adjustable 09 Water pump working Mode 0 Normal 1 Special 0 Adjustable 10 Automatic return water temp setting value 8 60 40 Adjustabl...

Page 20: ...is only valid remote controller Parameter table LCD or LED Parameter Meaning Range Default Remark 00 or 0 Cooling return water temp setting value 8 28 12 Adjustable 01 or 1 Heating return water temp...

Page 21: ...mp difference protection PP 06 or PP 6 Bright Cooling anti freezing protection PP 07 or PP 7 Bright Winter first grade anti freezing protection PP 07 or PP 7 Extinguish Winter second grade anti freezi...

Page 22: ...does not occur Discharge the water at the bottom of water pump if the unit will not be used for an extended period of time Check the unit thoroughly and fill the system with water fully before using...

Page 23: ...ire 4 Replace it with new high pressure switch 5 It is done by professionals EE 02 or EE 2 Low pressure protection 1 Check the connecting wire 2 Check if low pressure switch is broken 3 Check if lack...

Page 24: ...DAISHIBA Heating Refrigeration Equipment Co Ltd Web www daishiba com cn Tel 86 757 85213698 Fax 86 757 85213699 Email jenny daishiba com cn Add No 2 Chuangye Nan Road Songxia Industrial Park Songgang...

Reviews: