Depending on the reference of the chosen BEC LD, there are two working modes:

• 

Constant power

 (those marked with “Uout: 10 ... 50 V DC"): Will adjust the current and voltage

 (between 10 and 50 V DC) to give the power defined on the marking.

• 

Constant voltage

 (those marked with "Uout: 12 V DC ± 10%"): The current delivered will be adjusted to the lamp power or up to the 

power limit defined on the marking.

It allows two modes of operation depending on the wiring diagram chosen:
Non-maintained: A lamp that switches on only in an emergency.

Maintained: A lamp that switches on in an emergency and can be switched on/off when connected to mains power.

• 

WITH THE MAINS CONNECTED:

 The BEC is in normal mode and manages battery charging. The lamp can be switched on by means of 

an external LED driver (not included).

• 

IN THE CASE OF MAINS FAILURE:

 The BEC changes to emergency mode and works by turning on the lamp to which it is connected. 

It performs two types of tests automatically:

- Functional test (every 30 days): consists of simulating a mains failure and checking the operation of the lamp in an emergency.

-  Duration  test  (every  3  months):  consists  of  simulating  a  mains  failure,  checking  the  operation  of  the  lamp  in  emergency  mode  and 
recording the duration achieved.

The luminaire indicates its status by means of a two-colour LED

Note: if the admissible battery temperature range is exceeded, the inverter stops charging the battery

Optional: The finish (DM) has a 0...10V output that allows dimming of the external non-DALI dimmable driver when mains power is present.

Precautions

-All installation, maintenance or repair tasks must be performed by qualified personnel.
-The use of EN 60900/IEC 60900 insulated tools is recommended.

-The nominal voltage, duration, battery characteristics and suitable lamps are marked on the BEC.
-Before connecting, check that the mains voltage distribution corresponds to that specified on the BEC.

-Before  performing  any  installation  or  maintenance,  make  sure  that  the  luminaire  is  disconnected  from  the  power  supply  and  is  in  rest 
mode.

-Covering the BEC with insulation or similar material is not recommended.
-Storage time <3 months before mains connection and power-up. Storage temperature >5ºC and <45ºC.

-Keep these instructions in a safe place.

Assembly and installation instructions

1.- Check that the lamp to be connected does not have a built-in driver and is suitable for the chosen BEC (see example figure 1). 
2.- Disconnect the power supply to the installation (see figure 2).

3. - Find a suitable location for the converter, inside the luminaire, so that the battery is not close to heat sources to avoid shortening its life. 
Cables to the lamp should have the minimum length possible.

4.- Place the two-colour LED in a visible position. It may be necessary to make a ø5mm hole to attach it.
5.- Attach the converter module to its definitive location.

6.- Choose the desired wiring diagram for operation 

(Maintained 3A, 3B, 3C / Non-Maintained 3D)

 and make the connection.

7.- Connect the battery paying special attention to the polarity of the connectors (see figure 4).

8.- Connect the two-colour LED to its connector (see figure 5).
9.- Optional: On the finish (DM) connect the 0-10 V output to the Dimming input of the external driver (see diagram).

10.- Connect the power supply to the installation and check that the two-colour LED lights up showing the OK status (see figure 6).

Maintenance

-Maintenance must be carried out in accordance with EN 50172.

-The  BEC  has  a  battery  that  must  be  replaced  with  another  of  the  same  characteristics  when  the  luminaire  does  not  meet  its  nominal 

duration. In the event of a duration failure, after the battery has been replaced the BEC will perform a duration test (maximum 72h) so that 
the BEC failure signalling is updated.

-In the event of a lamp failure, after its replacement the luminaire will perform a functional test (maximum 48h) so that the BEC failure 
signalling is updated.

en

BEC LD …. DALI

The DAISALUX BEC LD emergency lighting converter, designed according to the EN 61347 standard, is a 

device that allows the integrated transformation of an LED luminaire with a very low voltage safety lamp 
into a self-contained emergency luminaire. It complies with EN 60598-2-22.

Luminaire status
Green LED

Amber LED

Meaning

Action to be taken

On

Off

OK

None

Slow blinking

Off

Duration test in progress

None

Fast blinking

Off

Functional test in progress

None

Off

1 pulse

Duration failure

Change b72h

Off

2 pulses

Lamp failure

Change lamp +48h

Off

3 pulses

Battery not charging

Check battery or repair BEC

Off

4 pulses

Electronic fault

Repair BEC

Off

On

Low battery voltage

Check battery or repair BEC

Off

Blinker

Battery temperature

Check the proper location

[BEC-LD_DALI]

www.daisalux.com

Summary of Contents for BEC LD DALI Series

Page 1: ...mpara a conectar no tiene driver incorporado y es apta para el BEC elegido Ver figura 1 2 Desconectar la alimentaci n de la instalaci n Ver figura 2 3 Busca una ubicaci n adecuada al convertidor en el...

Page 2: ...y and installation instructions 1 Check that the lamp to be connected does not have a built in driver and is suitable for the chosen BEC see example figure 1 2 Disconnect the power supply to the insta...

Page 3: ...incorpor et est adapt e pour le BEC choisi voir exemple figure 1 2 D brancher l alimentation de l installation Voir figure 2 3 Rechercher un emplacement adapt au convertisseur l int rieur du luminaire...

Page 4: ...e keinen Driver enth lt und f r den ausgew hlten BEC geeignet ist siehe Beispiel Abbildung 1 2 Stromversorgung der Installation unterbrechen siehe Abbildung 2 3 Einen f r den Konverter geeigneten Plat...

Page 5: ...e sia adatta al BEC scelto vedi esempio figura 1 2 Scollegare l alimentazione dell impianto vedi figura 2 3 Trovare un ubicazione adeguata per il convertitore all interno dell apparecchio di illuminaz...

Page 6: ...igar n o tem driver incorporado e est apta para o BEC selecionado ver exemplo da figura 1 2 Desligar a alimenta o da instala o Ver figura 2 3 Procurar uma localiza o adequada para o conversor no inter...

Page 7: ...instrukcje Instrukcja monta u i instalacji 1 Sprawdzi czy pod czana lampa nie ma wbudowanego sterownika i jest odpowiednia dla wybranego BEC patrz przyk ad na rysunku 1 2 Od czy zasilanie instalacji p...

Page 8: ...C Bewaar deze handleiding Installatie instructies 1 Controleer of de aan te sluiten lamp geen ingebouwde driver heeft en geschikt is voor de gekozen BEC zie voorbeeld figuur 1 2 Koppel de voeding van...

Page 9: ...C 1 BEC 1 2 2 3 4 5 5 6 3A 3B 3C 3D 7 4 8 5 9 DM 0 10 10 6 EN 50172 BEC BEC 72 BEC 48 BEC BEC LD Uout 10 50VDC 10 50 Uout 12VDC 10 BEC BEC 30 3 ru BEC LD DALI DAISALUX BEC EN 61347 EN 60598 2 22 1 72...

Page 10: ...EC LD DALI LED LED OK 72 1 48 2 BEC 3 BEC 4 BEC DM 0 10 DALI EN 60900 IEC 60900 BEC l BEC BEC 3 5 45 1 BEC 1 2 2 3 4 LED l 5 l 5 6 3A 3B 7 l 4 8 l LED 5 9 LED OK 6 EN 50172 BEC BEC 72 BEC 48 BEC BEC L...

Page 11: ...3 1 2 0 75 1 5mm2 1 2 3 1 5 2 5mm2 3A1 3B1 1 2 t 5 35 C Pol gono Industrial J ndiz C Ibarredi 4 01015 Vitoria Espa a Apdo 1578 TEL 34 945 29 01 81 www daisalux com BEC LD_DALI V240621...

Page 12: ...3C 3D www daisalux com BEC LD_DALI...

Page 13: ...6 24h I I 3 1 2 5 1 2 www daisalux com...

Reviews: