background image

Tetra

®

 PowerStrip Snap DS 

Installation Guide

3

Components

Electrical grade RTV silicone. 

Example electrical grade RTV silicones include:

•  Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant

•  Momentive White Blanc RTV 162 Silicone Rubber Adhesive 

Sealant-Electrical Grade

•  Dow Corning 3140 - Non-Corrosive Flowable (clear)

•  Dow Corning 3145 - Non-Corrosive Nonflowable (clear or gray)

•  Dow Corning RTV 748 Non-Corrosive Sealant-White

UL certified 18 AWG (0.82 mm

2

) supply wire

UL certified 22-14 AWG (0.33-2.08 mm

2

) wire 

connectors or 18-14 AWG (0.82-2.08 mm

2

) inline/

IDC connectors
#6 and #8 x 0.50 inch (M3 and M4 x 13mm) 

self-tapping screws or 1/8” rivets
Wire end caps 
Tetra

®

 24 VDC Power Supply

Tetra

®

 PowerStrip Snap DS

Tetra

®

 Snap 8ft. Rail (GEDSRL08-3)

Tetra

®

 Snap Socket Endcap (GEDSSE-3)

Tetra

®

 Snap Frame Endcap (GEDSFE-3)

Tetra

®

 Snap Interconnector (GEDSIC-3)

Tetra

®

 Snap T-Connector (GEDSTC-3)

T

C

 Measure Point

Optional

12

12

11

11

10

10

9

9

8

8

7

7

1

1

2

3

4

5

6

2

3

4
5
6

Summary of Contents for GE current Tetra PowerStrip Snap DS

Page 1: ...rentbyge com eu HU A telep t si tmutat s a biztnos gi inform ci k magyar nyelv v ltozata az al bbi c men tal lhat https products currentbyge com eu IT La versione italiana del manuale di installazione...

Page 2: ...lation RISQUE D INCENDIE OU DE CHOC LECTRIQUE L installation de l quipement de remplacement DEL exige Ia connaissance des syst mes lectriques pour enseignes Si non qualifi ne tentez pas d installation...

Page 3: ...y Dow Corning RTV 748 Non Corrosive Sealant White UL certified 18 AWG 0 82 mm2 supply wire UL certified 22 14 AWG 0 33 2 08 mm2 wire connectors or 18 14 AWG 0 82 2 08 mm2 inline IDC connectors 6 and 8...

Page 4: ...spacing Installation Using Tetra Snap Rails Align peg on top of the light module with hole on top of the Tetra Snap Rail and push module into rail until it snaps into place For added security fasten m...

Page 5: ...Connector must be secured with screws to the mounting rail Using Tetra Snap Interconnectors Alternative Mounting Using Tetra Snap T Connectors The modules may be attached to any structural member of t...

Page 6: ...low all federal and local regulations when disposing of neon tubing fluorescent tubes transformers and ballasts 3 Existing Signs Only If removal of the existing lighting equipment eliminates the disco...

Page 7: ...e non corrosive silicone for additional weather protection NOTES Exceeding maximum load will cause the power supply to shut down If overload occurs remove excess load recycle the input power to restar...

Page 8: ...wer Supply 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m 100W Power Supply 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m 180W Power Supply 20 ft 6 1 m 25 ft 7 6 m 35 ft 10 6 m 40 ft 12 1 m 300...

Reviews: