Installation Guide
LightGrid Node 2.x Series
Questions
• Email: [email protected]
• Leave a Voicemail: 1-877-843-5590
Troubleshooting
Symptom
Solution
The luminaire is not
turning ON.
Check that the pole has power. The relay inside the Controller is Normally Closed, so the
luminaire will always turn ON when the controller is first plugged in.
I did not see the
dimming sequence in the
first 60 seconds.
Unplug the controller, and try plugging it in again. If you still do not see the sequence, check
that the dimming wires of the fixture (Grey & Violet) are properly connected to the dimming
wires of the ANSI socket. If you confirm the wiring is connected and the controller still does
not dim the luminaire, try another new controller.