background image

14

TM-RHR-1214-A

Model: RHR20CV1

Indoor Unit

Outdoor Unit

Summary of Contents for WinterSpa RHR-C Series

Page 1: ...Heat Reclaim TM RHR 1214 A TECHNICAL MANUAL...

Page 2: ...Note Installation and maintenance are to be performed only by qualified personnel who are familiar with local codes and regulations and experienced with this type of equipment Caution Sharp edges and...

Page 3: ...1 TM RHR 1214 A 1 Model Name Power Supply V1 Single Phase Series Capacity Index 10 Based on Btu hr Type of Air Conditioner RHR Single Split Condensing Unit Heat Reclaim RHR 10 C V1 C C Series...

Page 4: ...2 TM RHR 1214 A Series Capacity 068 68 Litre Type of Air Conditioner YWS Water Tank WinterSpa B B Series YWS 068 B...

Page 5: ...visible Easy Installation There are vertical and horizontal water tanks Installation is made easier in narrow and difficult space Weather Resistance Built from highly durable material the DAIKIN Wint...

Page 6: ...12 7 1 2 355 14 6 35 1 4 9 52 3 8 540 700 250 29 R 22 CAPILLARY TUBE OUTDOOR INDUCTION MOTOR SEAMLESS INNER GROOVE COOPER ALUMINIUM SLIT FIN GALVANISED MILD STEEL FLARE 220 240 1 50 ROTARY 220 240 1...

Page 7: ...INDOOR FLARE 9 52 3 8 15 88 5 8 9 52 3 8 R 22 CAPILLARY TUBE OUTDOOR GALVANISED MILD STEEL SEAMLESS INNER GROOVE COOPER ALUMINIUM SLIT FIN 2 14 0 514 5 53 651 855 328 43 51 753 855 328 53 52 646 840...

Page 8: ...136 182 341 Imp Gallon 30 40 75 mm 510 510 610 mm 1250 1600 1930 Empty Tank kg 55 68 113 Full Tank kg 191 250 454 kPa Safety Relief Valve Setting Pressure bar Safety Relief Valve Setting Water Tempera...

Page 9: ...7 TM RHR 1214 A 4 Performance Curve Heating Time For YWS068B Heating Time For YWS136B RHR10CV1 RHR15CV1 RHR20CV1 RHR10CV1 RHR15CV1 RHR20CV1...

Page 10: ...s Characteristic For YWS068B 0 10 20 30 40 50 60 70 80 90 0 2 1 0 9 0 6 0 3 0 Time hours Tem perature o C Heat Loss Characteristic For YWS136B 0 10 20 30 40 50 60 70 80 90 100 0 2 1 0 9 0 6 0 3 0 Time...

Page 11: ...9 TM RHR 1214 A 5 Refrigerant Cycle Diagram...

Page 12: ...Q R S T U V 700 521 250 478 180 37 5 190 28 94 64 440 130 81 15 21 19 278 86 63 60 54 5 63 A B C D E F G H I J K L M N O P Q R S T U V 855 628 328 520 10 70 190 100 120 105 603 126 135 15 34 23 362 9...

Page 13: ...T D O L C G I J H N N F E V U S R B P M Q L Dimension Model RHR25CV1 A B C D E F G H I J K L M N O P Q R S T U V 855 730 328 520 180 32 190 81 104 113 603 126 185 15 34 23 362 116 83 62 83 83 All dime...

Page 14: ...12 TM RHR 1214 A 7 Wiring Diagram Indoor Unit Outdoor Unit Model RHR10CV1...

Page 15: ...13 TM RHR 1214 A Model RHR15CV1 Indoor Unit Outdoor Unit...

Page 16: ...14 TM RHR 1214 A Model RHR20CV1 Indoor Unit Outdoor Unit...

Page 17: ...15 TM RHR 1214 A Model RHR25CV1 Indoor Unit Outdoor Unit...

Page 18: ...16 TM RHR 1214 A Model RHR30BV1 Indoor Unit Outdoor Unit...

Page 19: ...d with the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is co...

Page 20: ...ding of the unit it may cause fire ignition Confirm drainage piping is connected properly If it is not connected perfectly it may cause water leakage and dampen the furniture Confirm the unit is switc...

Page 21: ...and isolating noise and vibration A place protected from the direct sunlight Otherwise use an awning for protection if necessary The location must not be susceptible to dust or oil mist Installation...

Page 22: ...rom the unit c Is there any abnormal vibrations with regard to unit itself or piping d Is there smooth drainage of water Check that 1 Condenser fan is running with warm air blowing off the condensing...

Page 23: ...ANY CORROSIVE ENVIRONMENT The Pressure and Temperature relief valve must be made accessible so that the lever can be operated and if required the valve replacement The tank is oriented so that instruc...

Page 24: ...pipe must be connected to the pressure and temperature relief valve The open end of the drain pipe must be connected to drain so that any discharge is visible but will not cause damage or scalding Ins...

Page 25: ...23 TM RHR 1214 A Tank Installation Diagram 9 22...

Page 26: ...y screen 5 Operation mode Press the MODE button to select the type of operating mode For cooling only unit the available modes are COOL DRY and FAN 6 Automatic air swing Press the SWING button to acti...

Page 27: ...timer function Set the desired on time by pressing the ON TIMER button continuously If the timer is set to 7 30am the air conditioner will turn on at 7 30am sharp Press the CANCEL button to cancel the...

Page 28: ...unction Press it again to deactivate it 4 QUIET Fan Speed Press the Quiet key once to activate Quiet fan speed Quiet symbol will be shown To disable Quiet fan speed and back to previous fan speed pres...

Page 29: ...blink next 6 Press UP or DOWN to change the minute 7 Press Timer ON OFF key again to confirm the minute Each timer Timer 1 ON or Timer 1 OFF or Timer 2 ON or Timer 2 OFF will only be set separately a...

Page 30: ...creen during the unit ON or OFF except for power failure or error code Set RTC Setting 1 Press RTC key one time will activate RTC setting mode Day will blink 2 Press UP or DOWN to select the day 3 Pre...

Page 31: ...ensor contact open short Blink E2 Indoor coil sensor contact open Blink E3 Outdoor coil sensor contact open Blink E4 Compressor overload Indoor coil sensor short Outdoor coil sensor short Blink E5 Gas...

Page 32: ...Device Actuated Reset Compressor locked to replace compressor Voltage supply not within range Check motor resistance and insulation M Compressor Capacitor Defective Loose Connections Improper wiring...

Page 33: ...uld be made by measuring temperature difference of indoor unit s intake and discharge air as well as running current Insufficient Cooling Unit Starts Excessive heat source e g electric kettle High coo...

Page 34: ...3 8 ASSY SERVICE VALVE 1 4 ASSY STOP VALVE 3 8 R22 TUBE DISCHARGE TUBE SUCTION PARTS DESCRIPTION NO 1 2 3 4 5 6 7 8 9 10 BRACKET MOTOR MOTOR MSL 10C AL 501 230V 6P 20W IPH FAN 16 INCH OZ42000 ASSY INS...

Page 35: ...VICE VALVE 1 4 ASSY 3 WAY VALVE 1 2 TUBE DISCHARGE TUBE SUCTION PARTS DESCRIPTION NO 1 2 3 4 5 6 7 8 9 10 BRACKET MOTOR MOTOR MSL 15C AL 501 6P 30 32W IPH 230V FAN 16 INCH OZ42000 ASSY INS PANEL LEFT...

Page 36: ...UBE CONDENSER INLET ASSY CAP TUBE FELT COMPRESSOR ASSY CONTROL BOX PARTS DESCRIPTION NO 11 12 13 14 15 16 17 18 19 20 21 ASSY BASE PAN ASSY OUTDOOR COIL SL18C 7MM COIL ASSY MOTOR BRACKET MOTOR MSL20C...

Page 37: ...SCHARGE TUBE CONDENSER ASSY CAP TUBE INLET FELT COMPRESSOR ASSY CONTROL BOX PARTS DESCRIPTION NO 11 12 13 14 15 16 17 18 19 20 21 ASSY BASE PAN ASSY OUTDOOR COIL SL25C IRX34THX20FPI BRACKET MOTOR MOTO...

Page 38: ...TM RHR 1214 A Model RHR30BV1 PARTS DESCRIPTION NO 1 2 3 4 5 6 7 8 9 10 COMPRESSOR PANEL SIDE ASSY FRONT PANEL ASSY BACK GRILLE PANEL TOP BRACKET MOTOR MOTOR FAN ASSY TERMINAL BOX ASSY INS ACCESS VALV...

Page 39: ...068B 090B 114B 136B 180B 340B 1 1 5 PARTS DESCRIPTION NO 1 2 3 4 5 6 7 8 9 10 BRACKET INNER BODY HEAT EXCHANGER INSPECTION COVER COLD WATER INLET HOT WATER OUTLET PIPE INSULATION OUTER BODY INLET FOR...

Page 40: ...el 06 288 1133 Sabah Tel 088 722 194 Sarawak Tel 082 333 299 Negeri Sembilan Tel 06 768 8969 Kedah Tel 04 733 0235 Kelantan Tel 09 747 4678 GROUP ASSOCIATED C L SDN BHD 109719 M Head Office Tel 03 795...

Reviews: