5
TM-RHR-1214-A
WinterSpa - RHR-C&B Series
RHR20CV1
RHR25CV1
RHR30BV1
WALL MOUNTED
CEILING CASSETTE
Btu/h
Btu/h
19,500
24,000
-
-
CEILING EXPOSED - E
CEILING EXPOSED - CB
Btu/h
Btu/h
20,000
20,000
20,000
25,000
25,000
25,000
30,000
CEILING CONCEALED
Btu/h
20,000
25,000
30,000
30,000
V/Ph/Hz
COMPRESSOR TYPE
RUNNING CURRENT
A
9.9
11.2
13.8
LOCKED ROTOR CURRENT
A
56
67
66
INPUT POWER
W
2009
2325
2670
PROTECTION DEVICE
POWER SOURCE
V/Ph/Hz
FAN TYPE / DRIVE
BLADE MATERIAL
AIR FLOW
cmm/cfm
1200
1400
DIAMETER
mm/in
A
0.50
0.56
0.59
W
110
133
140
MOTOR SPEED
RPM
775
775
830
MATERIAL
2 / 16
FACE AREA
m²/ft²
HEIGHT
mm
WIDTH
mm
DEPTH
mm
WEIGHT
kg
SOUND PRESSURE LEVEL
dBA
MATERIAL
TYPE
LIQUID
mm/in
6.35 / 1/4
GAS
WATER
mm/in
mm/in
R22/CAP.TUBE(INDOOR)
FLARE
9.52 / 3/8
15.88 / 5/8
9.52 / 3/8
R 22 / CAPILLARY TUBE (OUTDOOR)
GALVANISED MILD STEEL
SEAMLESS INNER GROOVE COOPER
ALUMINIUM (SLIT FIN)
2 / 14
0.514 / 5.53
651
855
328
43
51
753
855
328
53
52
646
840
330
58
56
REFRIGERANT TYPE & CONTROL
220-240 / 1 / 50
ROTARY
OVERLOAD PROTECTION
220-240 / 1 / 50
PROPELLER / DIRECT
GLASS REINFORCED ACRYL STYRENE RESIN
420 / 16.5
INDUCTION MOTOR
TUBE MATERIAL
F
IN
DIMENSION
CASING
P
IP
E
SIZE
OUTDOOR UNIT MODEL
TOTAL COOLING CAPACITY
(DEPENDING ON INDOOR UNIT)
O
U
T
D
O
O
R
U
N
IT
C
O
M
P
R
E
S
S
O
R POWER SOURCE
F
A
N
RUNNING CURRENT
INPUT POWER
MOTOR TYPE
C
O
IL
ROW / FIN PER INCH
1200
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO AHRI 210/240.
3) NOMINAL COOLING CAPACITY IS BASED ON THE FOLLOWING CONDITION: OUTDOOR -35˚C, INDOOR -27˚C DB / 19˚C WB.
4) WINTERSPA MUST USE GOVERNMENT TAP WATER FOR WATER USAGE, OTHERWISE THE WARRANTY WILL BE VOIDED.
Summary of Contents for WinterSpa RHR-C Series
Page 1: ...Heat Reclaim TM RHR 1214 A TECHNICAL MANUAL...
Page 11: ...9 TM RHR 1214 A 5 Refrigerant Cycle Diagram...
Page 14: ...12 TM RHR 1214 A 7 Wiring Diagram Indoor Unit Outdoor Unit Model RHR10CV1...
Page 15: ...13 TM RHR 1214 A Model RHR15CV1 Indoor Unit Outdoor Unit...
Page 16: ...14 TM RHR 1214 A Model RHR20CV1 Indoor Unit Outdoor Unit...
Page 17: ...15 TM RHR 1214 A Model RHR25CV1 Indoor Unit Outdoor Unit...
Page 18: ...16 TM RHR 1214 A Model RHR30BV1 Indoor Unit Outdoor Unit...
Page 25: ...23 TM RHR 1214 A Tank Installation Diagram 9 22...