background image

• VRV

®

 Systems • Indoor Units

7

• Indoor Units • 4-WAY BLOW CEILING SUSPENDED CASSETTE • FXUQ-MAV1

6

Dimensional drawing & centre of gravity

6 - 1 Dimensional drawing

3

FXUQ71MA

3D013860D

790 Suspension position

 

 

 

 

Drain connection 

location for upper 

piping

Brand name plate (Note 2)

790 Suspension position

1500mm 

or more

1500mm 

or more

1500mm 

or more

1500mm 

or more

Required space

1000mm or more (Requierd space)

Height of suspension bracket

Suspension bolt
4-M3~M10

Drain pipe can 

be raised up to  0mm from the top surface of the product.

Drain connection 

location for rear 

piping

When closing the discharge grill, the required space is 

30mm or more. (Note 3)

50

NOTES

1

Location for manufacture’s label: on bell mouth.

2

This is where the signal of infrared remote control is received.
Refer to the drawing of infrared remote control in detail.

3

When closing the discharge grill (2 or 3 way discharge), direction of pipe 
connection will be limited, please refer to Installation manual..

Nr

Part name

Description

1

Liquid pipe connection

ø9.5 Flare connection

2

Gas pipe connection

ø15.9  Flare connection

3

Drain pipe connection

VP20

4

Air  outlet

5

Air suction grille

6

Corner decoration cover

7

Right pipe/wiring connection

8

Rear pipe/wiring connection

9

Pipe through cover

10 Accessory drain elbow

FXUQ100-125MA

3D044898B

 

 

 

 

 

Drain connection 

location for upper 

piping

Drain connection 

location for rear 

piping

Drain pipe can be

raised up to 500mm from the top surface of the product.

Brand name plate (Note 2)

790 Suspension position

1500mm 

or more

1500mm 

or more

1500mm 

or more

1500mm 

or more

Required space

When closing the discharge grill, the required space is 

30mm or more. (Note 3)

790 Suspension position

1000mm or more (Requierd space)

Height of suspension bracket

Suspension bolt
4-M3~M10

NOTES

1

Location for manufacture’s label: on bell mouth.

2

This is where the signal of infrared remote control is received.
Refer to the drawing of infrared remote control in detail.

3

When closing the discharge grill (2 or 3 way discharge), direction of pipe 
connection will be limited, please refer to Installation manual..

Nr

Part name

Description

1

Liquid pipe connection

ø9.5 Flare connection

2

Gas pipe connection

ø15.9  Flare connection

3

Drain pipe connection

VP20

4

Air  outlet

5

Air suction grille

6

Corner decoration cover

7

Right pipe/wiring connection

8

Rear pipe/wiring connection

9

Pipe through cover

10 Accessory drain elbow

Summary of Contents for VRVIII-S Series

Page 1: ...technical data 4 Way Blow Ceiling Suspended Cassette FXUQ MAV1_BEVQ MAVE air conditioning systems EEDEN08 204 2e...

Page 2: ...ems 4 5 Capacity tables 5 Cooling capacity tables 5 Heating capacity tables 6 6 Dimensional drawing centre of gravity 7 Dimensional drawing 7 7 Piping diagram 8 8 Wiring diagram 9 Wiring diagram 9 9 S...

Page 3: ...fin coil Multi louver fins and N hix tubes Fan Type Turbo fan Quantity 1 1 1 Air Flow Rate Cooling High m min 19 00 29 00 32 00 Low m min 14 00 21 00 23 00 Heating High m min 19 00 29 00 32 00 Low m...

Page 4: ...1 00 Note For more details concerning conditional connections see http extranet daikineurope com select E Data Books Finally click on the document title of your choice 4D013856E FXUQ71MA FXUQ100MA FXU...

Page 5: ...FXUQ100MA FXUQ125MA WIRED REMOTE CONTROL BRC1D52 INFRARED REMOTE CONTROL Heat pump BRC7C528W Cooling only BRC7C529W FXUQ71MA FXUQ100MA FXUQ125MA CENTRALISED REMOTE CONTROL DCS302B51 UNIFIED ON OFF CON...

Page 6: ...10 5 8 0 11 2 8 2 11 9 8 3 13 4 8 4 14 0 8 1 20 0 7 6 6 6 9 0 7 1 10 5 8 0 11 2 8 2 11 9 8 3 13 4 8 4 13 8 8 0 21 0 7 6 6 6 9 0 7 1 10 5 8 0 11 2 8 2 11 9 8 3 13 4 8 4 13 7 7 9 23 0 7 6 6 6 9 0 7 1 10...

Page 7: ...13 0 8 9 8 9 8 9 8 9 8 9 8 8 10 5 11 0 9 4 9 3 9 3 9 3 9 3 9 3 9 5 10 0 9 6 9 6 9 5 9 5 9 5 9 5 8 5 9 1 9 8 9 8 9 7 9 7 9 7 9 7 7 0 7 6 10 1 10 1 10 1 10 1 10 1 10 0 5 0 5 6 10 6 10 5 10 5 10 5 10 5...

Page 8: ...ion VP20 4 Air outlet 5 Air suction grille 6 Corner decoration cover 7 Right pipe wiring connection 8 Rear pipe wiring connection 9 Pipe through cover 10 Accessory drain elbow FXUQ100 125MA 3D044898B...

Page 9: ...ASSETTE FXUQ MAV1 VRV Systems Indoor Units 8 7 Piping diagram 3 FXUQ MA 4D037995F Piping connection diameters Models A B FXUQ70 100 125MA 9 5 15 9 Indoor heat exchanger Indoor unit Field piping A C122...

Page 10: ...control A1P Printed circuit board SS1 Selector switch Emergency A3P Printed circuit board A2P Printed circuit board Transformer 220 240V 16V V1TR Phase controle circuit A4P Printed circuit board C1R...

Page 11: ...27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Return air temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB 5 Directions discharge 6 Location of microphone 7 Operating noise d...

Page 12: ...s 1 5m s 1 25m s 1 0m s 0 75m s 0 5m s 2 7m 2m 1m 0m 0m 1m 2m 3m 4m 1m 2m 3m 4m 20 C 21 C 22 C 23 C 24 C 25 C 26 C 0m 1m 2m 3m 4m 1m 2m 3m 4m 2 7m 2m 1m 0m FXUQ100MA Cooling air velocity distribution...

Page 13: ...1 1 0m 1m 2m 3m 4m 1m 2m 3m 4m 2 0m s 75m s 5m s 25m s 0m s 0 75m s 0 5m s 2 7m 2m 1m 0m 20 C 21 C 22 C 23 C 24 C 25 C 26 C 0m 1m 2m 3m 4m 1m 2m 3m 4m 2 7m 2m 1m 0m FXUQ71MA Heating air velocity distr...

Page 14: ...3m 4m 1m 2m 3m 4m 2 0m s 1 75m s 1 5m s 1 25m s 1 0m s 0 75m s 0 5m s 2 7m 2m 1m 0m 32 C 30 C 28 C 26 C 24 C 22 C 0m 1m 2m 3m 4m 1m 2m 3m 4m 2 7m 2m 1m 0m FXUQ125MA Heating air velocity distribution...

Page 15: ...9 15 9 Outdoor Unit Liquid OD Type Flare connection Diameter mm 9 5 9 5 9 5 Suction gas OD Type Flare connection Diameter mm 15 9 15 9 15 9 Standard Accessories Item Installation manual Gas piping co...

Page 16: ...r unit conncection 6 Wire connection port Power supply Ground 7 Wire connection port Transmission VRV Gas pipe thermistor BEVQ MA 3TW0453 100 or more Servicing space Servicing space Note 2 165 5 Suspe...

Page 17: ...Indoor Units 4 WAY BLOW CEILING SUSPENDED CASSETTE BEVQ MAVE VRV Systems Indoor Units 16 11 Junction box BEVQ MAVE 11 2 Dimensional drawing centre of gravity 3 BEVQ MA 3D030851D...

Page 18: ...ILING SUSPENDED CASSETTE BEVQ MAVE 11 Junction box BEVQ MAVE 11 3 Piping diagram 3 BEVQ MA 4D034127B Liquid piping connection port Gas piping connection port Liquid piping connection port Gas piping c...

Page 19: ...when using a central control unit Refer to the manual attached the unit when connecting 5 Cool Heat changeover of indoor units connected to BEV unit cannot be carried out unless they are connected to...

Page 20: ...ted therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage In the broadest sense arising from or related...

Reviews: