background image

• Indoor Units • 4-WAY BLOW CEILING SUSPENDED CASSETTE • FXUQ-MAV1

• VRV

®

 Systems • Indoor Units

2

1

Specifications

3

In

do

or

 U

ni

t

VR

V

®

 S

ys

te

ms

FX

UQ

-M

AV

1

4-

Wa

Bl

ow

 

1-1 TECHNICAL SPECIFICATIONS

FXUQ71MAV1

FXUQ100MAV1

FXUQ125MAV1

Power input 
(Nominal)

Cooling

kW

0.180

0.289

0.289

Heating

kW

0.160

0.269

0.269

Casing

Colour

White

Material

Resin

Dimensions

Packing

Height

mm

230

295

295

Width

mm

960

960

960

Depth

mm

960

960

960

Unit

Height

mm

165

230

230

Width

mm

895

895

895

Depth

mm

895

895

895

Weight

Unit

kg

25

31

31

Packed Unit

kg

35

42

42

Heat 
Exchanger

Dimensions

Length

mm

2101

2101

2101

Nr of Rows

3

3

3

Fin Pitch

mm

1.50

1.50

1.50

Nr of Passes

8

8

12

Face 
Area

0.265

0.353

0.353

Nr of Stages

6

8

8

Empty Tubeplate 
Hole

4

Fin

Fin type

Cross fin coil (Multi louver fins and N-hix tubes)

Fan

Type

Turbo fan

Quantity

1

1

1

Air Flow Rate

Cooling

High

m³/min

19.00

29.00

32.00

Low

m³/min

14.00

21.00

23.00

Heating

High

m³/min

19.00

29.00

32.00

Low

m³/min

14.00

21.00

23.00

Fan

Motor

Steps

2

2

2

Output 
(high)

W

45

90

90

Refrigerant

Name

R-410A

Sound Level

Cooling

Sound 
power 
(nominal)

dBA

56.0

59.0

60.0

Cooling

Sound 
Pressure

High

dBA

40.0

43.0

44.0

Low

dBA

35.0

38.0

39.0

Heating

Sound 
Pressure

High

dBA

40.0

43.0

44.0

Low

dBA

35.0

38.0

39.0

Piping 
connections

Liquid (OD)

Type

Flare connection

Diameter mm

9.5

9.5

9.5

Gas

Type

Flare connection

Diameter mm

15.9

15.9

15.9

Drain

Diameter mm

I.D. 20/O.D. 26

Heat Insulation

Heat resistant foamed polyethylene, regular foamed polyethylene

Air Filter

Resin net with mold resistance

Safety devices

Fan motor thermal protector

Standard 
Accessories

Standard Accessories

Installation and operation manual

Drain hose

Clamp metal

Insulation for fitting

Sealing Pads

Clamps
Washer

Summary of Contents for VRVIII-S Series

Page 1: ...technical data 4 Way Blow Ceiling Suspended Cassette FXUQ MAV1_BEVQ MAVE air conditioning systems EEDEN08 204 2e...

Page 2: ...ems 4 5 Capacity tables 5 Cooling capacity tables 5 Heating capacity tables 6 6 Dimensional drawing centre of gravity 7 Dimensional drawing 7 7 Piping diagram 8 8 Wiring diagram 9 Wiring diagram 9 9 S...

Page 3: ...fin coil Multi louver fins and N hix tubes Fan Type Turbo fan Quantity 1 1 1 Air Flow Rate Cooling High m min 19 00 29 00 32 00 Low m min 14 00 21 00 23 00 Heating High m min 19 00 29 00 32 00 Low m...

Page 4: ...1 00 Note For more details concerning conditional connections see http extranet daikineurope com select E Data Books Finally click on the document title of your choice 4D013856E FXUQ71MA FXUQ100MA FXU...

Page 5: ...FXUQ100MA FXUQ125MA WIRED REMOTE CONTROL BRC1D52 INFRARED REMOTE CONTROL Heat pump BRC7C528W Cooling only BRC7C529W FXUQ71MA FXUQ100MA FXUQ125MA CENTRALISED REMOTE CONTROL DCS302B51 UNIFIED ON OFF CON...

Page 6: ...10 5 8 0 11 2 8 2 11 9 8 3 13 4 8 4 14 0 8 1 20 0 7 6 6 6 9 0 7 1 10 5 8 0 11 2 8 2 11 9 8 3 13 4 8 4 13 8 8 0 21 0 7 6 6 6 9 0 7 1 10 5 8 0 11 2 8 2 11 9 8 3 13 4 8 4 13 7 7 9 23 0 7 6 6 6 9 0 7 1 10...

Page 7: ...13 0 8 9 8 9 8 9 8 9 8 9 8 8 10 5 11 0 9 4 9 3 9 3 9 3 9 3 9 3 9 5 10 0 9 6 9 6 9 5 9 5 9 5 9 5 8 5 9 1 9 8 9 8 9 7 9 7 9 7 9 7 7 0 7 6 10 1 10 1 10 1 10 1 10 1 10 0 5 0 5 6 10 6 10 5 10 5 10 5 10 5...

Page 8: ...ion VP20 4 Air outlet 5 Air suction grille 6 Corner decoration cover 7 Right pipe wiring connection 8 Rear pipe wiring connection 9 Pipe through cover 10 Accessory drain elbow FXUQ100 125MA 3D044898B...

Page 9: ...ASSETTE FXUQ MAV1 VRV Systems Indoor Units 8 7 Piping diagram 3 FXUQ MA 4D037995F Piping connection diameters Models A B FXUQ70 100 125MA 9 5 15 9 Indoor heat exchanger Indoor unit Field piping A C122...

Page 10: ...control A1P Printed circuit board SS1 Selector switch Emergency A3P Printed circuit board A2P Printed circuit board Transformer 220 240V 16V V1TR Phase controle circuit A4P Printed circuit board C1R...

Page 11: ...27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Return air temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB 5 Directions discharge 6 Location of microphone 7 Operating noise d...

Page 12: ...s 1 5m s 1 25m s 1 0m s 0 75m s 0 5m s 2 7m 2m 1m 0m 0m 1m 2m 3m 4m 1m 2m 3m 4m 20 C 21 C 22 C 23 C 24 C 25 C 26 C 0m 1m 2m 3m 4m 1m 2m 3m 4m 2 7m 2m 1m 0m FXUQ100MA Cooling air velocity distribution...

Page 13: ...1 1 0m 1m 2m 3m 4m 1m 2m 3m 4m 2 0m s 75m s 5m s 25m s 0m s 0 75m s 0 5m s 2 7m 2m 1m 0m 20 C 21 C 22 C 23 C 24 C 25 C 26 C 0m 1m 2m 3m 4m 1m 2m 3m 4m 2 7m 2m 1m 0m FXUQ71MA Heating air velocity distr...

Page 14: ...3m 4m 1m 2m 3m 4m 2 0m s 1 75m s 1 5m s 1 25m s 1 0m s 0 75m s 0 5m s 2 7m 2m 1m 0m 32 C 30 C 28 C 26 C 24 C 22 C 0m 1m 2m 3m 4m 1m 2m 3m 4m 2 7m 2m 1m 0m FXUQ125MA Heating air velocity distribution...

Page 15: ...9 15 9 Outdoor Unit Liquid OD Type Flare connection Diameter mm 9 5 9 5 9 5 Suction gas OD Type Flare connection Diameter mm 15 9 15 9 15 9 Standard Accessories Item Installation manual Gas piping co...

Page 16: ...r unit conncection 6 Wire connection port Power supply Ground 7 Wire connection port Transmission VRV Gas pipe thermistor BEVQ MA 3TW0453 100 or more Servicing space Servicing space Note 2 165 5 Suspe...

Page 17: ...Indoor Units 4 WAY BLOW CEILING SUSPENDED CASSETTE BEVQ MAVE VRV Systems Indoor Units 16 11 Junction box BEVQ MAVE 11 2 Dimensional drawing centre of gravity 3 BEVQ MA 3D030851D...

Page 18: ...ILING SUSPENDED CASSETTE BEVQ MAVE 11 Junction box BEVQ MAVE 11 3 Piping diagram 3 BEVQ MA 4D034127B Liquid piping connection port Gas piping connection port Liquid piping connection port Gas piping c...

Page 19: ...when using a central control unit Refer to the manual attached the unit when connecting 5 Cool Heat changeover of indoor units connected to BEV unit cannot be carried out unless they are connected to...

Page 20: ...ted therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage In the broadest sense arising from or related...

Reviews: