Before installation.............................................................................. 1

Important information regarding the refrigerant used........................ 2

Selecting installation site................................................................... 2

Indoor unit installation ....................................................................... 3

Refrigerant piping work ..................................................................... 4

Drain piping work .............................................................................. 5

Electric wiring work ........................................................................... 5

How to install the remote controller and wiring inside the unit .......... 6

Wiring examples................................................................................ 7

Field setting....................................................................................... 8

Test operation.................................................................................... 8

Maintenance...................................................................................... 8

Disposal requirements .................................................................... 10

Wiring diagram ................................................................................ 10

The English text is the original instruction. Other languages are
translations of the original instructions.

B

EFORE

 

INSTALLATION

Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling of
soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.

Refer to the installation manual of the outdoor unit for items not
described in this manual.

Caution concerning refrigerant series R410A:
The connectable outdoor units must be designed exclusively for
R410A.

Do not place objects in direct proximity of the outdoor unit and
do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit.
Once in the unit, such animals can cause malfunctions, smoke
or fire when making contact with electrical parts.

When moving the unit while removing it from the carton box, be
sure to lift it without exerting any pressure on other parts,
especially the refrigerant piping, drain piping and other resin
parts.

Precautions

Do not install or operate the unit in rooms mentioned below.
-

Places with mineral oil, or filled with oil vapour or spray like in 
kitchens. (Plastic parts may deteriorate.)

-

Where corrosive gas like sulphurous gas exists. (Copper 
tubing and brazed spots may corrode.)

-

Where volatile flammable gas like thinner or gasoline is used.

-

Where machines generating electromagnetic waves exist. 
(Control system may malfunction.)

-

Where the air contains high levels of salt such as air near the 
ocean and where voltage fluctuates a lot (e.g. in factories). 
Also in vehicles or vessels.

-

Where there is no risk of flammable gas leaking.

-

The equipment is not intended for use in a potentially 
explosive atmosphere.

Do not install accessories on the casing directly. Drilling holes in
the casing may damage electrical wires and consequently cause
fire.

This appliance is not intended for use by persons, including
children, with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.

Accessories

Check if the following accessories are included with your unit.

FXLQ20P7VEB

FXLQ40P7VEB

FXLQ25P7VEB

FXLQ50P7VEB

FXLQ32P7VEB

FXLQ63P7VEB

VRV System air conditioners

Installation and

operation manual

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

Installation must be done by a licensed technician. 
The choice of materials and installation must comply with
the applicable national and international regulations.

1

Metal clamp

6

Insulation for liquid pipe

2

Drain hose

7

Clamp

3

Leveling screw

8

Installation and operation 
manual

4

Sealing pad

5

Insulation for gas pipe

1x

1x

4x

1x

1x

1x

1

2

3

5

6

1x

8

8x

7

4

Summary of Contents for VRV

Page 1: ...INSTALLATION AND OPERATION MANUAL FXLQ20P7VEB FXLQ25P7VEB FXLQ32P7VEB FXLQ40P7VEB FXLQ50P7VEB FXLQ63P7VEB System air conditioners...

Page 2: ...UT D F1 F2 F1 F2 Control box L N L N P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 3 1 4 2 L N L N L N L N 2 1 2 3 7 9 8 10 4 5 6 NOTES L N IN D OUT D...

Page 3: ...em A e com o parecer positivo de B de acordo com o Certificado C 09 A B C 10 Bem rk som anf rt i A og positivt vurderet af B i henhold til Certifikat C 11 Information enligt A och godk nts av B enlig...

Page 4: ...Where volatile flammable gas like thinner or gasoline is used Where machines generating electromagnetic waves exist Control system may malfunction Where the air contains high levels of salt such as a...

Page 5: ...asures Keep indoor unit outdoor unit power supply wiring and transmission wiring at least 1 meter away from televisions and radios This is to prevent image interference and noise in those electrical a...

Page 6: ...fasten to the wall using the holes provided or fasten to the floor with a field supplied floor fastener Wallmounted installation 1 Positioning of holes for fastening to the wall Unit of measurement m...

Page 7: ...propriate tightening torque Overtightening may damage the flare and cause leaks When connecting the flare nut coat the flare inner surface with ether oil or ester oil and initially tighten 3 or 4 turn...

Page 8: ...ne A main switch or other means for disconnection having a contact separation in all poles must be incorporated in the fixed wiring in accordance with relevant local and national legislation Note that...

Page 9: ...the terminals Keep wiring in neat order so that they do not obstruct other equipment such as popping open the control box cover Make sure the cover closes tight Incomplete connections could result in...

Page 10: ...g rods or crossground with telephones Improper grounding could result in electric shock 1 Control box 2 Power supply wiring field supply 3 Remote controller wiring field supply 4 Transmission wiring f...

Page 11: ...the wiring again MAINTENANCE Wire specification Sheathed vinyl cord or cable 2 wire Gauge 0 75 1 25 mm2 Length Max 100 m External terminal Contact that can ensure the minimum applicable load of 15 V D...

Page 12: ...g the front as a leverage To install use the opposite method How to clean the drain strainer The drain strainer clears dirt out of the drain water and prevents the piping from clogging However if the...

Page 13: ...d of other parts must be done in accordance with relevant local and national legislation WIRING DIAGRAM A1P PRINTED CIRCUIT BOARD C1 CAPACITOR M1F F1U FUSE B 5 A 250 V HAP LIGHT EMITTING DIODE SERVICE...

Page 14: ...4PW53089 1B Copyright Daikin...