4 Preparation

Installation manual 

9

RWEQ96~432TAYCU 

VRV W T-Series water-cooled system air conditioner 

4P540122-1B – 2018.11

3 .5 .5

Possible options for the outside unit

INFORMATION 

Refer to the technical engineering data for the latest option 

names.

Refrigerant branching kit

In case of heat pump system

Description

Model name

Refnet header

KHRP26M22H9
KHRP26M33H9
KHRP26M72H9
KHRP26M73HU9

Refnet joint

KHRP26A22T9
KHRP26A33T9
KHRP26M72TU9
KHRP26M73TU9

In case of heat recovery system

Description

Model name

Refnet header

KHRP25M33H9
KHRP25M72H9
KHRP25M73HU9

Refnet joint

KHRP25A22T9
KHRP25A33T9
KHRP25M72TU9
KHRP25M73TU9

For the selection of the optimal branching kit, please refer to 

"4.3.3 To select refrigerant branch kits" on page 12.

Outside multi connection piping kit

In case of heat pump system

Number of outside units

Model name

2

BHFP22T84U

3

BHFP22T126U

In case of heat recovery system

Number of outside units

Model name

2

BHFP26T84U

3

BHFP26T126U

Cool/heat selector

In order to control the cooling or heating operation from a central 

location, the following option can be connected:

Description

Model name

Cool/heat change over switch

KRC19-26A6

Cool/heat change over PCB

BRP2A81

With optional fixing box for the 

switch

KJB111A

External control adaptor (DTA104A61/62)

To instruct specific operation with an external input coming from a 

central control the external control adaptor can be used. Instructions 

(group or individual) can be instructed for low noise operation and 

power consumption limitation operation.

PC configurator cable (999482P3)

You can make several commissioning field settings through a 

personal computer interface. For this option 999482P3 is required 

which is a dedicated cable to communicate with the outside unit.

4

Preparation

4 .1

Overview: Preparation

This chapter describes what you have to do and know before going 

on-site.
It contains information about:

▪  Preparing the installation site
▪  Preparing the refrigerant piping
▪  Preparing the water piping
▪  Preparing the electrical wiring

4 .2

Preparing installation site

4 .2 .1

Installation site requirements of the 

outside unit

CAUTION 

This unit is designed for indoor installation only. 

▪  Provide  required  service  space  around  the  unit  as  stated  in  the 

technical engineering book or in section "11.2 Service space: 

Outside unit" on page 48 of this manual.

▪  Ensure that the foundation is strong enough to support the weight 

of the unit and the floor is flat to prevent vibration and noise 

generation.

▪  Make  sure  the  area  is  well  ventilated.  Do  NOT  block  any 

ventilation openings.

▪  Make sure the unit is level.
▪  Make  sure  to  install  the  unit  in  a  machine  room  that  is  free  of 

moisture. The unit is designed for indoor use only.

▪  Select  the  location  of  the  unit  in  such  a  way  that  the  sound 

generated by the unit does not disturb anyone, and the location is 

selected according the applicable legislation.

Do NOT install the unit in the following places:

▪  In potentially explosive atmospheres.
▪  In  places  where  there  is  machinery  that  emits  electromagnetic 

waves. Electromagnetic waves may disturb the control system, 

and cause malfunction of the equipment.

▪  In  places  where  there  is  a  risk  of  fire  due  to  the  leakage  of 

flammable gases (example: thinner or gasoline), carbon fiber, 

ignitable dust.

▪  In places where corrosive gas (example: sulphurous acid gas) is 

produced. Corrosion of copper pipes or soldered parts may cause 

the refrigerant to leak.

▪  In places where a mineral oil mist, spray or vapor may be present 

in the atmosphere. Plastic parts may deteriorate and fall off or 

cause water leakage.

NOTE 

This is a class A product. In a domestic environment this 

product may cause radio interference in which case the 

user may be required to take adequate measures.