![background image](http://html1.mh-extra.com/html/daikin/vrv-system-r-22-plus-series/vrv-system-r-22-plus-series_manual_4076397108.webp)
Appendix
SiE33-102
106
General Information
7.4.3
PIPE SIZE REDUCER (For R-22)
This kit including followings;
This kits are pipe size reducers for REFNET JOINT and HEADER and applicable to following
REFNET CONNECTOR.
1. Select the field piping size according to the installation manual of the BRANCH PIPING KIT.
2. Connect the PIPE SIZE REDUCER suitable for the field piping size to the branch piping kit.
ex.)Connect the reducers to the branch piping kit, KHRJ26K75T. For inlet piping size is
φ
41.3 and outlet
1·2 piping size are
φ
34.9.
Name
Pipe size reducer (1)
Pipe size reducer (2)
Pipe size reducer (3)
Figure
Q’ty
KHRJ26K40TP
1
—
1
KHRJ26K40HP
—
—
1
KHRJ26K75TP
1
1
1
Kit Name
REFNET CONNECTOR
KHRJ26K40TP
KHRJ26K40T (Gas pipe)
KHRJ26K40HP
KHRJ26K40H (Gas pipe)
KHRJ26K75TP
KHRJ26K75T (Gas pipe)
(V1071)
(V1072)
(V1073)
The figure and size of pipe size reducers are as followings;
Pipe size reducer (1)
Pipe size reducer (2)
Pipe size reducer (3)
For
φ
34.9, cut the center of the part A.
ID
φ
34.9
OD
φ
31.8
124
(V1074)
Field
piping side
( )
124
ID
φ
41.3
OD
φ
38.1
Field
piping side
( )
(V1075)
185
ID
φ
41.3
ID
φ
34.9
OD
φ
31.8
Field
piping side
( )
(V1076)
Port A
Dimple
PIPE SIZE REDUCER (2)
PIPE SIZE REDUCER (3)
PIPE SIZE REDUCER (1)
CONNECTIONS
CONNECTIONS
CONNECTIONS
CUT AT THE CENTER
OF THE CONNECTIONS
WITH A PIPE CUTTER
CUT AT THE CENTER
OF THE CONNECTIONS
WITH A PIPE CUTTER
CUT AT THE CENTER
OF THE CONNECTIONS
WITH A PIPE CUTTER
ID
φ
44.5
KHRJ26K75T
(GAS SIDE)
ID
φ
38.1
ID
φ
38.1
ID
φ
38.1
ID
φ
25.4
ID
φ
31.8
OUTLET 1
OUTLET 2
FIELD PIPING
φ
41.3
INLET
FIELD PIPNG
φ
34.9
(V1829)
Si33-102.book Page 106 Tuesday, June 26, 2001 3:18 PM