Installation Manual
EDUS341411-N
12
Installation of Outdoor Units
3P362438-1B
2
3P362438-1B English
1. Introduction
1.1. General
information
This installation manual concerns the VRV IV, full inverter driven, heat
pump system.
6
7
6
6
3
3
3
5
4
2
1
8
1
VRV IV Heat pump outdoor unit
2
Refrigerant piping
3
VRV indoor unit
4
Branch Provider unit (required to connect Mini-split indoor
units)
5
Mini-split indoor units
6
User interface (dedicated depending on indoor unit type)
7
User interface (wireless, dedicated depending on indoor unit
type)
8
Cool/Heat selector
INFORMATION
Not all combinations of indoor units are allowed. For guidance, see
%QODKPCVKQPCPFQRVKQPUQPRCIG|
1.2. Combination and options
The VRV IV heat pump system can be combined with several types of
indoor units and is intended for R410A use only.
For an overview which units are available you can consult the product
catalogue for VRV IV.
NOTE
To be sure your system setup (outdoor unit + indoor unit(s)) will work,
you have to consult the latest technical engineering data for VRV IV
heat pump.
An overview is given indicating the allowed combinations of indoor
units and outdoor units. Not all combinations are allowed. They are
subject to rules (combination between outdoor-indoor, single outdoor
unit use, multiple outdoor unit use, combinations between indoor
units, etc.) mentioned in the technical engineering data.
1.2.1. Indoor unit combinations
In general following type of indoor units can be connected to a VRV
+8JGCVRWORU[UVGO6JGNKUVKUPQPGZJCWUVKXGCPFFGRGPFUQPDQVJ
outdoor unit model and indoor unit model combinations.
r
VRV indoor units.
r
Mini-split indoor units.
r
AHU (air to air applications): AHU Integration kit is required. See
NCVGUV'PIKPGGTKPI&CVC$QQMHQTOQTGFGVCKNU
1.2.2. Outdoor unit combinations
Standard combinations for VRV IV heat pump system are as indicated
in table below, where RXYQ192-408 consists of several RXYQ72-168
modules as indicated.
72
96
120
144
168
RXYQ72TTJU/TYDN
1
RXYQ96TTJU/TYDN
1
RXYQ120TTJU/TYDN
1
RXYQ144TTJU/TYDN
1
RXYQ168TTJU/TYDN
1
RXYQ192TTJU/TYDN
1
1
RXYQ216TTJU/TYDN
1
1
RXYQ240TTJU/TYDN
2
RXYQ264TTJU/TYDN
1
1
RXYQ288TTJU/TYDN
2
RXYQ312TTJU/TYDN
1
1
RXYQ336TTJU/TYDN
2
RXYQ360TTJU/TYDN
3
RXYQ384TTJU/TYDN
1
1
1
RXYQ408TTJU/TYDN
1
1
1
To install the outdoor unit, the following optional parts are also required.
1
Refrigerant branching kit.
Description
Model name
Refnet header
KHRP26M22H9
KHRP26M33H9
KHRP26M72H9
KHRP26M73HU9
Refnet joint
KHRP26M22T
KHRP26M33T
KHRP26M72TU9
KHRP26M73TU9
For the selection of the optimal branching kit, please refer to
5GNGEVKQPQHTGHTKIGTCPVDTCPEJMKVUQPRCIG|
2
Outdoor unit multi connection piping kit.
Number of outdoor units connected
2
3
BHFP22P100U
BHFP22P151U
3
In order to control the cooling or heating operation from a central
location, the following option can be connected:
- Cool/Heat selector: KRC19-26A
-
9KVJQRVKQPCNƂZKPIDQZHQTVJGUYKVEJ-,$#
- Centralized control devices (e.g., intelligent Touch Manager)
4
6QKPUVTWEVURGEKƂEQRGTCVKQPYKVJCPGZVGTPCNKPRWVEQOKPIHTQOC
EGPVTCNEQPVTQN
VJGGZVGTPCNEQPVTQNCFCRVQT&6##ECP
be used. Instructions (group or individual) can be instructed for low
noise operation and power consumption limitation operation.
5
For VRV IV heat pump system it is also possible to make several
EQOOKUUKQPKPIƂGNFUGVVKPIUVJTQWIJCRGTUQPCNEQORWVGTKPVGT
-
HCEG(QTVJKUQRVKQP'-2%%#$KUTGSWKTGFYJKEJKUCFGFKECVGF
cable to communicate with the outdoor unit. The software for the
user interface program can be obtained from your local Daikin
UCNGUQHƂEG
INFORMATION
Refer to the technical engineering data for the latest option names.
Summary of Contents for VRV IV RXYQ TTJU Series
Page 1: ...EDUS341411 N Installation...
Page 62: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 63 3P161697D...
Page 66: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 67 C 3P113151C 7 8 1 1 1 8...
Page 67: ...REFNET Joint and Header EDUS341411 N 68 Installation of Outdoor Units KHRP26M73HU 3P185500...
Page 68: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 69 3P185500...
Page 70: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 71 1P218719...
Page 71: ...REFNET Joint and Header EDUS341411 N 72 Installation of Outdoor Units 1P218719...
Page 72: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 73 1P218720...
Page 73: ...REFNET Joint and Header EDUS341411 N 74 Installation of Outdoor Units 1P218720...
Page 75: ...REFNET Joint and Header EDUS341411 N 76 Installation of Outdoor Units 1P280278A...
Page 76: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 77 1P280278A...
Page 77: ...REFNET Joint and Header EDUS341411 N 78 Installation of Outdoor Units 1P280279...
Page 79: ...Caution Label EDUS341411 N 80 Installation of Outdoor Units 2P361359C...
Page 80: ...EDUS341411 N Caution Label Installation of Outdoor Units 81 3P357947A...
Page 81: ...Caution Label EDUS341411 N 82 Installation of Outdoor Units 3P357947A...
Page 83: ...Caution Label EDUS341411 N 84 Installation of Outdoor Units 1P361833B...
Page 84: ...EDUS341411 N Caution Label Installation of Outdoor Units 85 1P361833B...
Page 85: ...Caution Label EDUS341411 N 86 Installation of Outdoor Units 1P361833B...
Page 86: ...EDUS341411 N Caution Label Installation of Outdoor Units 87 1P361833B...
Page 87: ...Caution Label EDUS341411 N 88 Installation of Outdoor Units 1P361833B...
Page 88: ...EDUS341411 N Caution Label Installation of Outdoor Units 89 1P361833B...
Page 89: ...Caution Label EDUS341411 N 90 Installation of Outdoor Units 3P357946A...
Page 90: ...EDUS341411 N Caution Label Installation of Outdoor Units 91 3P357946A...