background image

14

English

3. The system operates but cooling or heating is 

insufficient;

• Check if air inlet or outlet of outdoor or indoor unit 

is not blocked by obstacles.
Remove any obstacle and make it well-ventilated.

• Check if the remote controller display shows 

” (time to clean the air filter);

Refer to the operation manual of the indoor unit. 
And clean the air filter.

• Check the temperature setting.

Refer to “Operation procedure”.

• Check the fan speed setting on your remote con-

troller.
Refer to “Operation procedure”.

• Check for open doors or windows. 

Shut doors and windows to prevent wind from 
coming in.

• Check if there are too many occupants in the 

room during cooling operation.

• Check if the heat source of the room is excessive 

during cooling operation.

• Check if direct sunlight enters the room during 

cooling operation.
Use curtains or blinds.

• Check if the air flow angle is not proper.

Refer to “Operation procedure”.

After-sales service and warranty

After-sales service:

WARNING

• Do not modify the unit.

This may cause electric shock or fire.

• Do not disassemble or repair the unit.

This may cause electric shock or fire.
Contact your dealer.

• If the refrigerant leaks, keep out of fire.

Although the refrigerant does not usually leak, if 
the refrigerant leaks out into a room and comes in 
contact with the combustible air in the equipment 
such as fan heater, stove, oil (gas) cooker, etc., it 
will cause toxic gas to be generated.
When a refrigerant leakage failure has been 
repaired, confirm a service person that the 
leakage point has been corrected surely before 
restarting operation.

• Do not remove or reinstall the unit by yourself.

Incorrect installation may cause electrical shock 
or fire.
Contact your dealer.

• When asking your dealer to repair, inform 

related staff of the details as follows:

• Product No. of air conditioner: 

Refer to the warranty card.

• Shipping date and installation date: 

Refer to the warranty card.

• Malfunction: 

Inform the staff of the defective details.
(Malfunction code being displayed on the 
remote controller.)

• Name, address, telephone number

• Repair where the warranty term is expired

Contact your dealer.  If necessary to repair, pay 
service is available.

• Minimum storage period of important parts

Even after a certain type of air conditioner is dis-
continued, we have the related important parts in 
stock for 9 years at least.
The important parts indicate parts essential to 
operate the air conditioner.

• Recommendations for maintenance and 

inspection

Since dust collects after using the unit for several 
years, the performance will be deteriorated to 
some extent.
Taking apart and cleaning inside require technical 
expertise, so we recommend entering a mainte-
nance and inspection contract (at a cost) separate 
from normal maintenance.

• Recommended inspection and maintenance 

cycles
[Note: The maintenance cycle is not the same 
as the warranty period.]

Table 1 assumes the following usage conditions.

1. Normal use without frequent starting and stop-

ping of the machine.
(Although it varies with the model, we recom-
mend not starting and stopping the machine
more than 6 times/hour for normal use.)

2. Operation of the product is assumed to be 

10 hours/day, 2500 hours/year.

01_EN_3P226891-15V.fm  Page 14  Friday, September 19, 2014  9:26 AM

Summary of Contents for vrv III -Q Series

Page 1: ...PY13 OPERATION MANUAL System air conditioner Operation manual VRVIII System air conditioner Betriebsanweisung VRVIII System Klimaanlage Manuel d utilisation Conditionneur d air VRVIII System Manual de...

Page 2: ...alatarjetadegarant adelconcesionario gu rdelaen unlugarseguro Grazie per avere acquistato questo condizionatore d aria Daikin Prima di utilizzare quest ultimo leggere attentam ente il presente manuale...

Page 3: ...2 1 1 4 3 5 6 7 1 7 3 7 2 1 2 00_CV_3P226891 15V fm Page 3 Tuesday September 16 2014 6 53 PM...

Page 4: ...8 9 10 11 12 13 14 1 14 2 15 00_CV_3P226891 15V fm Page 4 Tuesday September 16 2014 6 53 PM...

Page 5: ...ly may result in property damage or personal injury which may be serious depending on the circum stances After reading keep this manual in a conve nient place so that you can refer to it whenever nece...

Page 6: ...y smoke such as cooking rooms or in places with flammable gas corrosive gas or metal dust Using the product in such places may cause fire or product failures Do not use flammable materials e g hairspr...

Page 7: ...ealth Do not let children play on or around the out door unit If they touch the unit carelessly injury may be caused Do not place water containers flower vases etc on the unit as this may result in el...

Page 8: ...3 3 3 Model RQCEQ280PY13 RQCEQ360PY13 RQCEQ460PY13 Power supply Phase 3N 3N 3N Frequency Hz 50 50 50 Voltage V 380 415 380 415 380 415 Nominal cooling capacity kW 28 0 36 0 46 0 Nominal heating capaci...

Page 9: ...y ventilation air cleaning This display shows that the ventilation unit are in operation these are optional accessories 6 Display set temperature This display shows the temperature you have set 7 Disp...

Page 10: ...s 80 or over the interiors of the indoor units may cause icing and water leakage may result Heating operation The air conditioner may stop operating for the pro tection of the machine if the outdoor t...

Page 11: ...ration it may take longer to reach the set temperature than in cooling operation We recommend starting the operation which was used before using timer operation The following operation is performed in...

Page 12: ...on off button The operation lamp lights up and the system starts operation Press the air flow direction adjust button only for FXC FXF FXH FXK FXA Refer to the chapter Adjusting the air flow directio...

Page 13: ...the sys tem after 3 hours and start the system after 4 hours the system will stop after 3 hours and start 1 hour later 6 5 SETTING THE MASTER REMOTE CON TROLLER Refer to figure 10 When one outdoor uni...

Page 14: ...TIMUM OPERATION Observe the following precautions to ensure the system operates properly Adjust the air outlet properly and avoid direct air flow to room inhabitants Adjust the room temperature proper...

Page 15: ...ng the air filter be sure to put it back in the same position See the operation manual included with the indoor unit for details on how to clean it 9 FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROU BL...

Page 16: ...d by defrost becomes steam and is exhausted 9 8 NOISE OF AIR CONDITIONERS Indoor unit A zeen sound is heard immediately after the power supply is turned on The electronic expansion valve inside an ind...

Page 17: ...a fuse a breaker or an earth leakage breaker frequently actuates Measure Do not turn on the main power switch If the ON OFF switch does not properly work Measure Turn off the main power switch If wat...

Page 18: ...been corrected surely before restarting operation Do not remove or reinstall the unit by yourself Incorrect installation may cause electrical shock or fire Contact your dealer When asking your dealer...

Page 19: ...ong as possible Use for appropriate maintenance design budgeting maintenance and inspection fees etc Contact your dealer for details Note Breakage due to taking apart or cleaning inside by anyone othe...

Page 20: ...3P226891 15V EM14A015 1410 HT 00_CV_3P226891 15V fm Page 5 Tuesday September 16 2014 6 53 PM...

Reviews: