SiBE341027
Wiring Diagrams
Appendix
199
2. Wiring Diagrams
RQYQ8PY1B
(BA
CK)
A3P
A5P
A4P
L1R
(FR
ONT)
X3A
X1M
M1F
M1C
5
A9P
X2A
UV
W
X1M
A2P
WHT
BLK
RED
X1A
WHT
BLK
RED
A1P
X2A
X1A
R1T
N=5
5
Z3C
EL.COMPO
.BO
X
Z5C
X11A
X111A
X1A
OUTER SHELL
X2A
V1R
V1R
X41A
-
+
X4A
X3A
-
+
F1U
R10
X5A
R50
R59
X5A
M1C
M1F
N1
P1
+
+
EL.COMPO
.BO
X
C66
C63
A5P
LA
YOUT OF M1C
,M2C
,M1F
P2
P3
WHT
V
RED
R95
BLK
L1R
N3
U
Z4C
L2-WHT
indoor (F1) (F2)
L3-BLK
N-BLU
L1-RED
COOL/HEA
T SELECT
OR (OPTIONAL A
CCESSOR
Y)
WHT
K1R
W
outdoor (F1) (F2)
P1
S2S
FA
N
HEA
T
outdoor (Q1) (Q2)
X4A
-
+
PS
TERMINAL OF M1C
,M2C
COOL
V2R
COOL
HEA
T
S1S
X6A
NO
TE) 5
K2M
Z2C
X61A
X10A
X1A
X3A
A4P
AB
C
F1
Q2
F2
F1
Q1
F2
M
5
5
C/H SELECT
OR
X28A
Y2E
X66A
X1A
X1M
X1M
X23A
WHT
RED
BLK
A9P
X29A
X30A
1
1
X401A
X403A
BS3
BS2
BS4
BS5
BS1
X402A
K4M
K3R
F400U
X14A
X11A
X12A
R6T
R7T
R2T
R4T
R5T
WHT
R3T
X16A
X13A
V1CP
WHT
BLK
BLU
RED
Z1F
X15A
X20A
P
<
M
X4A
5
X400A
N
L3
X1M
L1
L2
R8T
S2PH
R9T
Y1E
WHT
A3P
RED
BLK
GRN
BLU
X10A
X37A
Y6S
Y7S
Y13S
Y14S
Y9S
Y5S
Y8S
Y12S
Y11S
X21A
X3A
Y1S
Y2S
Y10S
Y3S
Y4S
E1HC
1234
PNK
OFF
X9A
3
1
4
1
2
24
3
S1NPH
WHT
HAP
X4A
X3A
X5A
X23A
X8A
X7A
NO
TE) 4.
X2A
X32A
ON
Z6C
DS1
PNK
K8R
K2R
K3R
K7R
K6R
K4R
K5R
K1R
S1PH
HAP
X9A
X11A
X8A
X13A
X7A
X15A
P
<
S1NPL
K11R
K7R
K9R
K5R
K4R
K3R
X31A
BLK
Q1RP
F2U
F1U
X1A
BLU
R1T
N
L3
L1
L2
A2P
RED
F1U
X1A
X18A
A1P
C1
Z1C N=2
Y1:380-415V
PO
WER SUPPL
Y
3N~50Hz
3~
MS
t˚
3~
MS
t˚
t˚
RED
S2NPH
WHT
t˚
t˚
t˚
t˚
t˚
t˚
PS
t˚
:
:
:
NO
TES)
1.THIS
WIRING DIA
GRAM IS APPLIED ONL
Y
TO
THE OUTDOOR UNIT
.
2.
:
FIELD
WIRING.
3.
:
TERMINAL STRIP :
CONNECT
OR :
TERMINAL :
PR
O
TECTIVE EAR
TH (SCREW)
4.WHEN USING
THE OPTIONAL AD
APT
OR, REFER
TO
THE INST
ALLA
TION MANU
AL OF
THE OPTIONAL AD
APT
OR.
5.FOR CONNECTION
WIRING
TO
INDOOR-OUTDOOR
TRANSMISSION F1 • F2, OUTDOOR-OUTDOOR
TRANSMISSION
F1 • F2, OUTDOOR-MUL
TI
TRANSMISSION Q1 • Q2, REFER
TO
THE INST
ALLA
TION MANU
AL.
6.HO
W
TO
USE BS1~5 AND DS1 SWITCH, REFER
TO
"SER
VICE PRECA
UTION" LABEL ON EL.COMPO
.BO
X, LID
.
7.WHEN OPERA
TING, DON'T SHOR
TCIRCUIT
THE PR
O
TECTION DEVICE (S1PH).
8.COLORS BLK :
BLA
CK RED :
RED BLU :
BLUE
WHT :
WHITE PNK :
PINK
YL
W :
YELLO
W BRN :
BR
O
W
N GR
Y :
GRA
Y
GRN :
GREEN ORG :
ORANGE.
TO
IN/D UNIT
TO OUT/D UNIT
TO
MUL
TI UNIT
H1PH2PH3PH4P
H5PH6PH7PH8P
IS CONNECT
OR COLOR FOR
PRINTED CIRCUIT BO
ARD
.
IS CONNECT
OR COLOR FOR COMPONENT
.
IS DISCRIMINA
TION COLOR FOR
COMPONENT LEAD
WIRE.
HAP
K2M
K4M
K1R
K1R
K2R
K3R
K3R
K3R
K4R
K4R
K5R
K5R
C1
C63,C66
DS1
E1HC
F1U
F1U
,F2U
F400U
H1P~8P
A1P
A2P
A3P
A4P
A5P
A9P
BS1~5
PRINTED CIRCUIT BO
ARD (MAIN)
PRINTED CIRCUIT BO
ARD (SUB)
PRINTED CIRCUIT BO
ARD (NOISE FIL
TER)
PRINTED CIRCUIT BO
ARD (INV)
PRINTED CIRCUIT BO
ARD (F
AN)
PRINTED CIRCUIT BO
ARD (ABC I/P)
PUSH B
UTTON SWITCH
(MODE,SET
,RETURN,TEST
,RESET)
CAP
A
CIT
OR
CAP
A
CIT
OR
DIP SWITCH
CRANKCASE HEA
TER
FUSE (8A,DC650V) (A5P)
FUSE (T
,3.15A,250V) (A1P)
FUSE (T
,6.3A,250V) (A3P)
PILO
T LAMP (SER
VICE MONIT
OR-ORANGE)
[H2P] PREP
ARE,
TEST
--------------------FLICKERING
MALFUNCTION DETECTION---LIGHT UP
PILO
T LAMP (SER
VICE MONIT
OR-GREEN)
MA
GNETIC CONT
A
C
TOR (M1C) (A4P)
MA
GNETIC CONT
A
C
TOR (M1C) (A3P)
MA
GNETIC RELA
Y (Y5S) (A2P)
MA
GNETIC RELA
Y (A4P)
MA
GNETIC RELA
Y (Y6S) (A2P)
MA
GNETIC RELA
Y (Y1S) (A1P)
MA
GNETIC RELA
Y (Y7S) (A2P)
MA
GNETIC RELA
Y (A3P)
MA
GNETIC RELA
Y (Y2S) (A1P)
MA
GNETIC RELA
Y (Y8S) (A2P)
MA
GNETIC RELA
Y (Y3S) (A1P)
MA
GNETIC RELA
Y (Y9S) (A2P)
K6R
K7R
K7R
K8R
K9R
K11R
L1R
M1C
M1F
PS
Q1RP
R10
R50,R59
R95
R1T
R1T
R2T
R3T
R4T
R5T
R6T
R7T
R8T
R9T
S1NPH
S1NPL
S2NPH
S1PH
S2PH
V1CP
V1R
MA
GNETIC RELA
Y (Y14S) (A2P)
MA
GNETIC RELA
Y (E1HC) (A1P)
MA
GNETIC RELA
Y (Y11S
, Y12S)(A2P)
MA
GNETIC RELA
Y (Y13S) (A2P)
MA
GNETIC RELA
Y (Y10S) (A1P)
MA
GNETIC RELA
Y (Y4S) (A1P)
REA
CT
OR
MO
T
OR (COMPRESSOR)
MO
T
OR (F
AN)
SWITCHING PO
WER SUPPL
Y (A1P
,A4P)
PHASE REVERSAL DETECT CIRCUIT
RESIST
OR (CURRENT SENSOR)(A4P
,A5P)
RESIST
OR
RESIST
OR (CURRENT LIMITING)
THERMIST
OR (AIR) (A1P)
THERMIST
OR (FIN) (A4P)
THERMIST
OR (RECEIVER)
THERMIST
OR (M1C DISCHARGE)
THERMIST
OR (REF
.LIQ.)
THERMIST
OR (HEA
T EXC
.OUTLET)
THERMIST
OR (LIQ.PIPE)
THERMIST
OR (REF
.GAS OUT)
THERMIST
OR (SUCTION)
THERMIST
OR (HEA
T EXC
.DEICER)
PRESSURE SENSOR (HIGH)
PRESSURE SENSOR (LO
W)
PRESSURE SENSOR (HIGH LIQ.)
PRESSURE SWITCH (HIGH)
PRESSURE SWITCH (CONTR
OL)
SAFETY DEVICES INPUT
PO
WER MODULE (A4P
, A5P)
CONNECT
OR FOR OPTIONAL P
A
R
T
S
X9A
COOL/HEA
T SELECT
OR
S1S
S2S
PO
WER SUPPL
Y (AD
APT
OR) (A2P)
SELECT
OR SWITCH (F
AN/COOL • HEA
T)
SELECT
OR SWITCH (COOL/HEA
T)
V2R
X1A,X2A
X3A
X1M
X1M
X1M
Y1E
Y2E
Y1S
Y2S
Y3S
Y4S
Y5S
Y6S
Y7S
Y8S
Y9S
Y10S
Y11S
Y12S
Y13S
Y14S
Z1C~6C
Z1F
DIODE BRIDGE (A4P)
CONNECT
OR (M1F)
CONNECT
OR (Y2E)
TERMINAL STRIP (PO
WER SUPPL
Y)
TERMINAL STRIP (CONTR
OL) (A1P)
TERMINAL STRIP (ABC I/P)(A9P)
ELECTR
ONIC EXP
ANSION
VA
LVE (MAIN)
ELECTR
ONIC EXP
ANSION
VA
LVE (SUBCOOL)
SOLENOID V
A
LVE
(HO
TGAS)
SOLENOID V
A
LVE
(OIL)
SOLENOID V
A
LVE
(4
W
AY V
A
LVE)
SOLENOID
V
A
LVE (MIX IN)
SOLENOID
V
A
LVE (RETURN OIL)
SOLENOID V
A
LVE
(LIQ.CLOSE)
SOLENOID
V
A
LVE (RECEIVER LIQ.)
SOLENOID
V
A
LVE (RECEIVER GAS)
SOLENOID
V
A
LVE (OIL OUT)
SOLENOID
V
A
LVE (MAIN BYP
ASS)
SOLENOID
V
A
LVE (REF
.GAS OUT)
SOLENOID V
A
LVE
(REF
.LIQ.IN)
SOLENOID
V
A
LVE (REF
.GAS IN)
SOLENOID V
A
LVE
(REF
.LIQ.OUT)
NOISE FIL
TER (FERRITE CORE)
NOISE FIL
TER (WITH SURGE ABSORBER)
C:
3D069092B