background image

20

HXY48TAVJU EDUS392021-F18

C: 4P616151-1

13. NOT AVAILABLE 

n

  This icon is displayed whenever a non-installed option is addressed or a function is not available. A function not available can mean insufficient 

permission level or can mean that a slave user interface is used (see installation manual).

Master Slave

Permission

level 2 level 3

Operation ON/OFF

Setting the leaving water temperature

Setting the room temperature

Weather dependent set point operation ON/OFF

Setting the clock

Programming the schedule timer

Schedule timer operation ON/OFF

Field settings

Malfunction code display

Test operation

 = operable

14. DEFROST/START UP MODE ICON 

d

 

This icon indicates that the defrost/start up mode is active.

15. COMPRESSOR ICON 

ç

 

This icon indicates that the compressor in the outdoor unit of the system is active.

16. PUMP ICON 

é

 

This icon indicates that the circulation pump is active.

17. OUTDOOR TEMPERATURE DISPLAY 

u

  When this icon is flashing, the outdoor ambient temperature is displayed. Refer to “10.3.7.  Temperature read-out mode” in the installation manual 

for more information.

18. WEATHER DEPENDENT SET POINT ICON 

a

  This icon indicates that the controller will adapt the leaving water temperature set point automatically, based on the outdoor ambient temperature 

(during heating operation).

19. TEMPERATURE ICON 

b

 

This icon is displayed when the actual room temperature or room temperature set point is shown.

  The icon is also displayed when the temperature set point is set in schedule timer programming mode. Refer to “10.3.7. Temperature read-out 

mode” in the installation manual for more information.

20. TEST OPERATION ICON 

t

 

This icon indicates that the unit runs in test mode.

21. FIELD SET CODE 

;

  This code represents the code from the field set list. Refer to the “8.3. Field settings” in the installation manual.

22. MALFUNCTION CODE 

:

  This code refers to the malfunction code list and is for service purposes only. Refer to the malfunction code list “8.6.2. Malfunction codes list” in the 

installation manual.

23. BUTTON 

w

 

This button has no function.

24. WEATHER DEPENDENT SET POINT BUTTON 

ba

 

This button enables or disables the weather dependent set point function which is available in space heating operation.

  If the controller is set to permission level 3 (refer to “Field settings” in the installation manual), the weather dependent set point button will not be 

operable.

25. INSPECTION/TEST OPERATION BUTTON 

z

  This button is used for installation purposes and changing field settings. Refer to “8.3. Field settings” in the installation manual.

26. PROGRAMMING BUTTON 

<

 

This multi-purpose button is used to program the controller. The function of the button depends on the actual status of the controller or on previous 
actions carried out by the operator.

27. SCHEDULE TIMER BUTTON 

r

/

p

 

The main function of this multi-purpose button is to enable/disable the schedule timer.

 

The button is also used to set the clock and to program the controller. The function of the button depends on the actual status of the controller or on 
previous actions carried out by the operator.

28. TIME ADJUST BUTTONS 

pi

 and 

pj

  These multi-purpose buttons are used to adjust the clock, to toggle between temperatures (water inlet/outlet temperature of the unit, outdoor 

ambient temperature, actual room temperature) and in schedule timer programming mode.

Summary of Contents for VRV HXY48TAVJU

Page 1: ...Low temperature hydrobox HXY48TAVJU EDUS392021 F18 202009 Engineering Data 60 Hz...

Page 2: ......

Page 3: ...tio 4 4 Nomenclature 5 5 Specifications 6 6 Dimensions 7 7 Piping Diagrams 8 8 Wiring Diagrams 9 9 Electric Characteristics 11 10 Pump Performance Characteristics 12 11 Capacity 13 12 Center of Gravit...

Page 4: ...temperature range from 50 to 113 F 10 to 45 C without electric heater Super wide operating range for hot cold water production from 4 to 110 F 20 to 43 C ambient outdoor temperature Saves time on syst...

Page 5: ...HXY48TAVJU VJ VJ 1 phase 208 230 V 60 Hz 1 Low temperature hydrobox index for calculating system capacity shows in below table Please use the index at system connection ratio calculation Target T dif...

Page 6: ...of the low temperature hydrobox and indoor units Please refer the dedicated Engineering Data Book for the specification of respective indoor units ton 6 8 10 12 14 Minimum VRV indoor unit number 1 Min...

Page 7: ...2021 F18 4 Nomenclature Minor revision Power supply symbol VJ 1 phase 208 230V 60Hz Indicates minor change category Indicates major design category Capacity index 48 48 000 Btu h Low temperature hydro...

Page 8: ...C 5 4 to 14 4 3 to 8 Control method Inlet Outlet delta T control Outlet temp range Cooling F C 50 to 68 10 to 20 Heating F C 77 to 113 25 to 45 Ambient temp range Cooling F C 50 to 109 10 to 43 Heatin...

Page 9: ...7 HXY48TAVJU EDUS392021 F18 6 Dimensions HXY48TAVJU 3D128656 Unit in mm...

Page 10: ...F18 7 Piping Diagrams HXY48TAVJU 3D079034 THERMISTOR R1T R2T R3T R4T DESCRIPTION OUTLET WATER HEAT EXCHANGER THERMISTOR INLET WATER HEAT EXCHANGER THERMISTOR REFRIGERANT LIQUID SIDE THERMISTOR REFRIGE...

Page 11: ...9 HXY48TAVJU EDUS392021 F18 8 Wiring Diagrams HXY48TAVJU C 3D128650...

Page 12: ...efrigerant gas thermistor C1 C3 Filter capacitor S1L Flow switch F1U Fuse T 3 15A 250V SS1 A1P Selector switch emergency HAP PCB LED SS1 A2P Selector switch main sub K1E Electronic expansion valve SS1...

Page 13: ...7 V 2 5 15 135 Symbol MCA Min Circuit Amps A MOP Max Overcurrent Protective Device A Note 1 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit is not below o...

Page 14: ...3D128653 ESP External Static Pressure Flow Water flow through the unit Note Selecting a flow outside the operating area can damage the unit or cause the unit to malfunction See also the minimum and m...

Page 15: ...13 HXY48TAVJU EDUS392021 F18 11 Capacity...

Page 16: ...14 HXY48TAVJU EDUS392021 F18 12 Center of Gravity HXY48TAVJU 4D129458...

Page 17: ...15 HXY48TAVJU EDUS392021 F18 13 Operation Limits HXY48TAVJU 3D128655 Ta Ambient Temperature LWT Leaving Water Temperature...

Page 18: ...16 HXY48TAVJU EDUS392021 F18 C 4P616151 1 14 Accessories Option HXY48TAVJU Drain pan EKHBDPCA2 Remote user interface EKRUAHTB 4D128652...

Page 19: ...late of the user interface Be careful NOT to damage it Fixation of the user interface to the wall in case of installation as room thermostat 1 Cut off a 2 wire conductor 2 Fix the wallplate of the use...

Page 20: ...e M Master Only the remote controller set as master can work as room thermostat How to connect for multi unit INFORMATION For multiple unit control connect the remote controller to the unit as instruc...

Page 21: ...ctionality 5 DAY OF THE WEEK INDICATOR 1234567 This indicator shows the current day of the week When reading or programming the schedule timer the indicator shows the set day 6 CLOCK DISPLAY 8 The clo...

Page 22: ...he installation manual for more information 20 TEST OPERATION ICON t This icon indicates that the unit runs in test mode 21 FIELD SET CODE This code represents the code from the field set list Refer t...

Page 23: ...r dependent set point operation is selected the unit has a floating set point In this case the a icon as well as the shift value in case not zero will display 30 ROOM TEMPERATURE ADJUST BUTTONS bi and...

Page 24: ...8 16 Drain Pan EKHBDPCA2 C 4P325064 2C 4x x 6 4x 4x B A C D E F G H 1 2 3 4 5 1 2 60 mm 60 mm 2x 2 1 1 1 0 1 9 9 8 7 x 6 2x 3x 3x 6x A A E F G H E x 1 3 1 4 1 5 1 6 1 7 1 8 1 5 4 3 2 1 8 7 6 C D C B B...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories...