background image

English

17

VKM50

·80

·100GV1

3D048372-1

A1P

A2P

C1

·C2

F1U

F1U

F1UT

·

F2UT

HAP

HAP

K1R~K3R

K4R~K6R

K7R

M1D

M1F

M2F

R1T

R2T

R3T

R4T,R5T

S1Q

SS1

T1R

T2R

PRINTED CIRCUIT BOARD

PRINTED CIRCUIT BOARD

CAPACITOR (M1F, M2F)

FUSE (  B  , 10A, 250V)(A1P)

FUSE (  B  , 5A, 250V)(A2P)

THERMO SWITCH

(152

˚C)(M1F, M2F BUILT-IN)

LIGHT EMITTING DIODE

(SERVICE MONITOR-GREEN)(A1P)

LIGHT EMITTING DIODE

(SERVICE MONITOR-GREEN)(A2P)

MAGNETIC RELAY (M1F)(A1P)

MAGNETIC RELAY (M2F)(A1P)

MAGNETIC RELAY (M1D)(A1P)

MOTOR (DAMPER MOTOR)

MOTOR (SUPPLY AIR FAN)

MOTOR (EXHAUST AIR FAN)

THERMISTOR (INDOOR AIR)

THERMISTOR (OUTDOOR AIR)

THERMISTOR 

(INLET AIR INTO COIL)

THERMISTOR

(LIQUID/GAS PIPE OF COIL)

LIMIT SWITCH 

(DAMPER MOTOR)

SELECTOR SWITCH

(FOR ESPECIALLY USE)(A1P)

TRANSFORMER 

(220-240V/22V)

TRANSFORMER 

(220-240V/22V)

X1M

X2M

X3M

X17A,X19A

X20A

Y1E

TERMINAL BLOCK 

(POWER SUPPLY)

TERMINAL BLOCK

(CONTROL)(A1P)

TERMINAL BLOCK

(CONTROL)

CONNECTOR 

(RELAYING WIRE)

CONNECTOR 

(RELAYING WIRE)

ELECTRONIC EXPANSION 

VALVE

  2.                    : FIELD WIRING  

  3. 

IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED 

INSTRUCTION MANUAL.

  4. 

IN CASE USING WIRING ADAPTER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED INSTALLATION 

MANUAL.

  5.

WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FRESH UP CONTROL OPERATION CAN BE SELECTED BY 

REMOTE CONTROLLER, IN DETAILS, REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT.

  6.

WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED OFF OR ON/OFF CONTROL OPERATION CAN BE 

SELECTED BY REMOTE CONTROLLER, IN DETAILS, REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT.

  7.

DO NOT REMOVE THE SHORT CIRCUIT CONNECTORS OF X8A AND X9A, THE UNIT WILL NOT RUN IF THEY ARE 

REMOVED.

  8.

SS1(A1P) HAS ALREADY BEEN SET TO 

“NOR.

” AT FACTORY SET. THE UNIT WILL NOT RUN IF THE SETTING ARE 

CHANGED.

  9.

SYMBOLS SHOW AS FOLLOWS. (PNK: PINK   WHT: WHITE   YLW: YELLOW    ORG: ORANGE   BLU:BLUE

BLK: BLACK   RED: RED   GRN: GREEN)

10.

USE COPPER CONDUCTORS ONLY.

: TERMINAL BLOCK,

: TERMINAL,

: CONNECTOR,

: SHORT CIRCUIT CONNECTOR

1.

Notes)

OPTIONAL ACCESSORIES

WIRED REMOTE CONTROLLER

SS1

Ry1

Ry2

Tes10

SELECTOR SWITCH

(MAIN/SUB)

ADAPTOR PC BOARD FOR WIRING

(KRP50-2)

MAGNETIC RELAY

(OPERATION/STOP)

MAGNETIC RELAY

(FOR HUMIDIFIER OPERATION)

TERMINAL BLOCK

(FOR EXTERNAL OUTPUT)

CONNECTOR FOR 

OPTIONAL PARTS

X11A

X18A

CONNECTOR

(ADAPTER POWER 

SUPPLY)(A1P)

CONNECTOR 

(WIRING ADAPTER FOR 

ELECTRICAL APPENDICES)(A2P)

,

WIRING DIA

GRAM

Note) 4

Note) 8

Note) 7

POWER SUPPLY

220-240V

~

50Hz

ADAPTER PC BOARD FOR WIRING

(OPTIONAL ACCESSORIES)

EXTERNAL OUTPUT

TERMINALS

CONTACT

CAPACITY

Note) 6

INPUT FROM OUTSIDE

Note) 3

TO CONNECTION WIRING AND

CENTRAL REMOTE 

CONTROLLER UNIT

WIRED REMOTE CONTROLLER

(OPTIONAL ACCESSORIES)

Note) 5

INPUT 

FROM 

OUTSIDE

CONTROL BOX

01_3P130768-1A_En.fm  Page 17  Wednesday, March 23, 2005  7:00 PM

Summary of Contents for VKM50GMV1

Page 1: ...grilles d aspiration vacuation d air avant l installation de cette unit HRV Ventilaci n con recuperaci n de calor Por favor lea cuidadosamente el manual de instalacion e instale correctamente la unid...

Page 2: ...ita ku Osaka 530 8323 Japan DAIKIN INDUSTRIES LTD EN60335 2 40 VKM50GMV1 VKM50GV1 VKM80GMV1 VKM80GV1 VKM100GMV1 VKM100GV1 DAIKIN TCF 009 KEMA 59277 KRQ ECM95 4303 3P155750 1 Yoshiaki Hirata Manager Qu...

Page 3: ...age electric shock fire or other accidents Be sure to ground Do not connect the ground wire to gas or water pipes light ning rod or a telephone ground wire Incomplete grounding may result in electric...

Page 4: ...eck the type of R410A refrigerant to be used before installing the unit Using an incorrect refrigerant will prevent normal operation of the unit For the installation of an outdoor unit refer to the in...

Page 5: ...local govern ment office or fire department for details When discharging exhaust air to a common duct the Building Standard Law requires the use of fire proof materials so attach a 2m copper plate st...

Page 6: ...nger bracket without putting force on other parts when unpacking or moving the unit As for the parts to be used for installation work be sure to use the provided accessories and specified parts desig...

Page 7: ...he diameter of the connecting pipe pipe size PT3 4B When piping passes indoors always insulate it all the way to the base of the drain socket In areas where freezing may occur always take steps to pre...

Page 8: ...nnual operating hours 10 hours day 26 days month 5 month 1 300 hours 5 Insulate all piping that passes indoors After checking that the water supply piping connections do no leak insulate them using th...

Page 9: ...sely the refrigerant piping system Do not use anti oxidants or other similar agent when braz ing the pipe joints Residue can clog the pipes and may cause breakdown of parts 8 DUCT CONNECTION Perform d...

Page 10: ...ler This system consists of multiple indoor units Mark each indoor unit as unit A unit B and be sure the terminal board wiring to the outdoor unit and BS unit are properly matched If wiring and piping...

Page 11: ...parts box and secure with the included clamping material after connecting the wires to terminal blocks Refer to Fig 17 1 17 2 Precautions when laying power supply wiring PRECAUTIONS 1 A circuit breake...

Page 12: ...entire system Connect the remote controller and transmission wiring their respective terminal blocks 10 4 Wiring for the humidity regulator locally procured VKM GMV1 series only Pass into the electri...

Page 13: ...40V 50 Hz Fuse Switch Power supply 220 240V 50 Hz F1 F2 F1 F2 L N P1 P2 F1 F2 T1 T2 Transmission wiring Outdoor unit Remote controller wiring IN D OUT D Electric parts box HRV A Outside air processing...

Page 14: ...ernal start stop input settings based on 11 FIELD SETTING AND TEST RUN 10 8 Central control If control is performed with a central device central manage ment controller etc group number needs to be se...

Page 15: ...mode to enter the local setting mode 2 Use the TEMPERATURE ADJUSTMENT button to select the desired Mode No The code display will blink 3 To make settings for individual units under group control when...

Page 16: ...for details on the external input terminal function SECOND CODE NO 04 does not function when in air condi tioner linked mode Description of setting Mode No 1 FIRST CORD NO SECOND CORD NO 01 02 03 04 0...

Page 17: ...upply solenoid valve will be heard every 3 or 4 minutes a clicking sound so listening for that clicking sound let the unit run for 30 minutes to make sure that humidifying operation is normal CAUTION...

Page 18: ...ALVE 2 FIELD WIRING 3 IN CASE USING CENTRAL REMOTE CONTROLLER CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED INSTRUCTION MANUAL 4 IN CASE USING WIRING ADAPTER CONNECT IT TO THE UNIT IN ACCORDA...

Page 19: ...N BE SELECTED BY REMOTE CONTROLLER IN DETAILS REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT 6 WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE FORCED OFF OR ON OFF CONTROL OPERATION CAN BE SELECTED B...

Page 20: ...EM03A096A 0504 3P130768 1B FS HT 00_3P130768 1B_CV fm Page 2 Friday April 1 2005 8 39 AM...

Reviews: