2.5 NIGHTTIME FREE COOLING OPERATION

AUTOMATIC HEAT PORGE FUNCTION AT NIGHT

The nighttime free cooling is an energy-conserving function 
which works at night when the air conditioners is off, reducing 
the cooling load in the morning when the air conditioner is 
turned on by ventilating rooms which contain office equipment 
which raises the room temperature.

• Nighttime free cooling only works during cooling and when 

connected to Building Multi or VRV systems.

• Nighttime free cooling is set to “off” in the factory settings; so 

request your dealer to turn it on if you intend to use it.

Operation image

(a) Outside temperature

(b) Indoor temperature

(c) Set temperature

(d) Operating state of Air conditioner

(e) Operating state of Total heat exchanger

„

EXPLANATION OF NIGHTTIME FREE COOLING 
OPERATION IMAGE

The unit compares the indoor and outdoor temperatures after 
the air conditioning operation stops for the night. If the following 
conditions are satisfied, the operation starts, and when the 
indoor temperature reaches the air conditioning setting, the 
operation stops.

<Conditions>

[1] the indoor temperature is higher than the air conditioning 

setting and

[2] the outdoor temperature is lower than the indoor tempera-

ture,

If the above conditions are not satisfied, reevaluation is made 
every 60 minutes.

3

OPERATION PROCEDURE

3.1 COOLING, HEATING, AND FAN ONLY OPERA-

TION (Refer to figure 5)

[PREPARATIONS]

• To protect the unit, turn on the main power switch 6 hours 

before operation.
Do not turn off the power during the heating or cooling sea-
son. This is to ensure smooth start-up.

Press the operation mode selector button several times 
and select the operation mode of your choice;

” Cooling operation

” Heating operation

” Fan only operation

NOTE

• “

” can only be set for systems operating in cooling and 

heating at the same time.

” is displayed on all remote controllers when 

using the VRV

ΙΙ

 system cooling only type, but only “

” and 

” can be set.

• Select the operating mode on a remote controller on which 

” is not displayed.

” “

” and “

” (only for simultaneous cooling/heat-

ing systems) cannot be selected on remote controllers on 
which it is displayed.

See 3.2 if “

” is displayed.

Press ventilation mode selector button if you wish to 
change the  mode.
The display rotates through the following selections 
every time the button is pressed.

NOTE

• Above is available only if the remote controller BRC1D527 is 

connected with this unit.
It is unnecessary to change ventilation mode because the 
mode is already set to “automatic mode”.

• If you change this mode with BRC1A62, consult your dealer.

Press ventilation fan speed button if you wish to change 
the fan speed.
The display rotates through the following selections 
every time the button is pressed.

After the selection, the ventilation fan speed display dis-
appears.
And the fan speed of the combined air conditioner regu-
larly displays.

NOTE

• Above is available only if the remote controller BRC1D527 is 

connected with this unit.

• It is unnecessary to change four speed mode because the 

mode is already set to “Low” or “High” mode by the installer.

• If you want to know or change this mode with BRC1A62 con-

sult your dealer.

Press the on/off button.
The operation lamp lights up and the system starts oper-
ation.

Stopping the system

Press start/stop one more time. The operation lamp will go off. 
The unit will stop.

• After stopping operation, the fan may continue operating for 

up to a minute.

• The fan may stop, but this is not a malfunction.

OFF

ON

ON

OFF

OFF

OFF

40

30

20

(time)

Following morning

22:00

24:00

(d)

(e)

Oper

ating state 

T

emper

ature (˚C)

Nighttime free cooling operation

(a)

(b)

(c)

1

2

Automatic mode

Heat exchange mode

Bypass mode

3

Low

High

L

H

4

01_EN_3P130767-3G.fm  Page 7  Monday, March 5, 2007  10:05 AM

Summary of Contents for VKM100GAMV1

Page 1: ...ий OPERATION MANUAL Total Heat Exchanger HRV Heat Reclaim Ventilation with DX Coil MODELS Ceiling mounted duct type With DX coil Humidifier VKM50GAMV1 VKM80GAMV1 VKM100GAMV1 With DX coil VKM50GAV1 VKM80GAV1 VKM100GAV1 00_CV_3P130767 3G_01 fm Page 1 Wednesday March 7 2007 3 18 PM ...

Page 2: ...e al condizionatore d aria per interni sistema VRVII di tipo M RXYQ REYQ RXQ È anche possibile utilizzare questa unità come sistema indipendente L unità non può controllare la temperatura del locale Se ciò è necessario non installare l unità HRV da sola ma invece installare un altra unità interna Per controllare l unità utilizzare il telecomando del condizionatore d aria interno a sistema VRVII HR...

Page 3: ...e cover 6 Electric parts box 8 Heat exchanger elements 12 Gas pipe 13 Liquid pipe 16 Strainer included VKM GAMV1 series only VKM GAMV1 series only 14 Drain outlet 15 Humidifier Natural evaporating type 19 Remote controller Optional accessory 11 Direct expansion coil 9 Name plate 10 Air supply fan 4 Air filter Long life filter 5 Damper 21 EA Exhaust air to outdoors 22 OA Fresh air from outdoors out...

Page 4: ...dent system HRV With DX Coil Remote controller for indoor unit Outdoor unit Remote controller for VRV BRC1A62 3 2 Remote controller for VRV BRC1A62 4 1 5 3 Remote controller for VKM BRC1D527 EU only 4 5 UNIT No GROUP Remote controller for VKM BRC1D527 EU only 4 1 2 3 2 00_CV_3P130767 3G_02 fm Page 2 Friday March 2 2007 6 37 PM ...

Page 5: ... BRC1D527 EU only 1 2 3 6 1 Heat exchanger element 2 2 Handle 3 Rail 9 1 Air filter 8 2 8 1 3 10 11 12 1 3 2 Remote controller for VRV BRC1A62 7 6 7 UNIT No GROUP Remote controller for VKM BRC1D527 EU only 1 2 4 7 8 3 5 6 00_CV_3P130767 3G_02 fm Page 3 Friday March 2 2007 6 37 PM ...

Page 6: ...ot including air filters etc Be sure to stop the unit and turn off the power when cleaning or inspecting it As the fan is rotating at high speed it will cause injury Never inspect or service the unit by yourself Ask a qualified service person to perform this work The qualified service person Keep all flames away if the refrigerant leaks The refrigerant in the air conditioner is safe and normally d...

Page 7: ... When the HRV unit is to be installed in a small room it is necessary to take proper measures so that the amount of any leaked refrigerant does not exceed the limiting concen tration even when it leaks If the refrigerant leaks exceeding the level of limiting concentration an oxygen deficiency acci dent may happen Do not install the HRV unit at any place where flamma ble gas may leak out If the gas...

Page 8: ...ditioner CHECK LIST CORRESPONDING TO OPERATING NOISE Is the unit installed at the following locations a Location strong enough to support the weight of the unit and which will not amplify noise or vibration b Location where the warm air and the noise from the outlet vent of the outdoor unit will not bother neighbors Are any obstructions near the outlet vent of the outdoor unit They may reduce the ...

Page 9: ...tton for programming start and or stop time 18 Temperature setting button Use this button for setting the desired temperature of air conditioner combined with this unit This button can t use for this unit This unit can t change temperature setting 19 Filter sign reset button Refer to 4 1 HOW TO CLEAN THE AIR FILTER 20 Fan speed control button Press this button to select the fan speed of air condit...

Page 10: ...sing the unit as an independent system Ask your dealer what kind of system your system is set up for before operation For the operation of the remote controller for indoor unit and centralized controller refer to the instruction manual provided with each unit See the included operating manuals for details on how to operate each remote control OPERATION for EACH SYSTEM Sample system Refer to figure...

Page 11: ...t exchange mode VRV Fan mode HRV Heat exchange mode VRV Stopping HRV Heat exchange mode When air conditioner and HRV unit are not connected via duct Operation mode VRV Cooling mode HRV Heat exchange mode VRV Fan mode HRV Heat exchange mode When air conditioner and HRV unit are connected via duct Operation mode VRV Cooling mode HRV Heat exchange mode VRV Fan mode HRV Heat exchange mode VRV Stopping...

Page 12: ...set for systems operating in cooling and heating at the same time is displayed on all remote controllers when using the VRVΙΙ system cooling only type but only and can be set Select the operating mode on a remote controller on which is not displayed and only for simultaneous cooling heat ing systems cannot be selected on remote controllers on which it is displayed See 3 2 if is displayed Press ven...

Page 13: ...ues driv ing factory setting The purpose of this is to maintain the amount of ventilation and humidifying The change of the layout in the room should be examined when the cold draft from air supplying opening is feared Though the fan can be stopped by the setting of remote con troller Do not stop the fan in the place where no ventilation by stop ping the fan may cause the influence of diffusion of...

Page 14: ...D SET THE TIMER WITH THE REMOTE CONTROLLER BRC1A62 Refer to figure 7 The timer is operated in the following two ways Programming the stop time The system stops operating after the set time has elapsed Programming the start time The system starts operating after the set time has elapsed The start and the stop time can be simultaneously pro grammed Press the timer mode start stop button several time...

Page 15: ...ered you must confirm the programmed actions Make sure the last schedule timer action you want to keep is selected schedule timer actions with a higher number will be deleted Now you must choose between 2 options 1 CONFIRM AND COPY TO NEXT DAY The schedule timer action programmed for the current day are also valid for the next day use the confirm last action and copy actions to next day function b...

Page 16: ...CESSARY Increase the frequency of cleaning if the unit is installed in a room where the air is etermely contaminated If the dirt becomes impossible to clean change the air filter Air filter for exchange is optional 1 Detach the maintenance cover Go into ceiling through the inspection hatch remove binding metal of maintenance cover and take it off Refer to figure 8 1 2 Detach the air filter Take ou...

Page 17: ...oller does not display any error code Usage under that status will lead to insufficient humidification and increased tap water consumption The solenoid valve should be checked at the beginning of the heating season For dealers 4 5 INSPECTION OF THE FAN MOTER NOTE When the fan motor fails the remote controller does not dis play any error code Usage under that status will lead to insufficient ventil...

Page 18: ...the power on The remote control buttons do not work well Measure Turn off the main power switch If the display INSPECTION UNIT No and the OPERATION lamp flash and the MALFUNCTION CODE appears Measure Notify and inform the model name and what the malfunction code indicates to your Daikin dealer There are other malfunctions Measure Stop the unit List of malfunction codes of Remote controller of the ...

Page 19: ...board and other electric parts h Is the float switch broken Replace the float switch i Is the water supply pressure sufficient Re set it so that there is sufficient pressure j Is there foreign matter in the feed water tank Clean the feed water tank After sales service and warranty After sales service WARNING Do not modify the unit This may cause electric shock or fire Do not disassemble or repair ...

Page 20: ... wear out parts The cycle is not the same as the warranty period Table 2 Replacement Cycle Lists Note 1 This table indicates main parts See the maintenance and inspection contract for details Note 2 This maintenance cycle indicates recommended lengths of time until the need arises for maintenance work in order to ensure the product is operational as long as possible Use for appropriate maintenance...

Page 21: ...3P130767 3G EM05A069A 0704 HT 00_CV_3P130767 3G_01 fm Page 2 Wednesday March 7 2007 3 18 PM ...

Reviews: