background image

 

UK.PPC150

-

300(SL)/R32

 

 

November 

2022

—Version 2.1

 

Domestic hot water tank for Daikin Altherma Monobloc (R32)

 

 

 

12.3

 

Technical specifications

 

Part Number

 

UK.PPC150

 

UK.PPC180

 

UK.PPC210

 

UK.PPC250

 

UK.PPC300

 

Description 

 

 

  

150l pre

-

plumbed 

cylinder

 

180l pre

-

plumbed 

cylinder

 

210l pre

-

plumbed 

cylinder

 

250l pre

-

plumbed 

cylinder

 

300l pre

-

plumbed 

cylinder

 

Suitable for 

 

 

  

Daikin Altherma R32 Monobloc

 

Energy efficiency class 

 

 

  

B

 

B

 

C

 

C

 

C

 

Standing heat loss (ErP) 

  

W

 

54

 

58

 

63

 

88

 

96

 

Storage volume 

  

L

 

148

 

179

 

209

 

248

 

301

 

Integrated vessel storage volume

 

L

 

33

 

33

 

33

 

33

 

33

 

Standing heat loss

 

kWh/

24h

 

1.29

 

1.39

 

1.50

 

2.10

 

2.29

 

Max. water temperature 

  

°C

 

90

 

Primary immersion capacity 

  

kW

 

3

 

Primary immersion power supply 

 

 

  

1

-

phase / 230V / 50Hz

 

Primary immersion recommended fuse

 

A

 

16

 

Secondary immersion capacity 

  

kW

 

3

 

Secondary immersion power supply 

 

 

  

1

-

phase / 230V / 50Hz

 

Secondary immersion recommended fuse

 

A

 

16

 

Height 

  

mm

 

1400

 

1526

 

1714

 

2014

 

1877

 

Diameter 

  

mm

 

550

 

550

 

550

 

550

 

600

 

Empty weight 

  

kg

 

46

 

56

 

59

 

71

 

86

 

Material inside cylinder 

  

  

Stainless steel 2304

 

Water inlet H/E

 

mm

 

28

 

Piping connections 
(diameter) 

 

 

 

 

  

Water outlet H/E

 

mm

 

28

 

Cold water in

 

mm

 

22

 

Hot water out

 

mm

 

22

 

Domestic hot water cylinder 

 

 

  

UK.PPC150SL

 

UK.PPC180SL

 

Description 

 

 

  

150l slimline pre

-

plumbed cylinder

 

180l slimline pre

-

plumbed cylinder

 

Suitable for 

 

 

  

Daikin Altherma R32 Monobloc

 

Energy efficiency class 

 

 

  

B

 

B

 

Standing heat loss (ErP) 

  

W

 

52

 

58

 

Storage volume 

  

L

 

152

 

178

 

Integrated vessel storage volume

 

L

 

25

 

25

 

Standing heat loss 

  

kWh
/24h

 

1.23

 

1.39

 

Max water temperature 

  

°C

 

90

 

Primary immersion capacity 

  

kW

 

3

 

Primary immersion power supply 

 

 

  

1

-

phase / 230V / 50Hz

 

Primary immersion recommended fuse 

  

A

 

16

 

Secondary immersion capacity 

  

kW

 

3

 

Secondary immersion power supply 

 

 

  

1

-

phase / 230V / 50Hz

 

Secondary immersion recommended fuse 

  

A

 

16

 

Height 

  

mm

 

1869

 

1970

 

Diameter 

  

mm

 

475

 

475

 

Empty weight 

  

kg

 

59

 

67

 

Material inside cylinder 

 

 

  

Stainless steel 2304

 

Water inlet H/E

 

mm

 

28

 

Piping connections 
(diameter) 

 

 

 

 

  

Water outlet H/E

 

mm

 

28

 

Cold water in

 

mm

 

22

 

Hot water out

 

mm

 

22

 

12.3.1

 

Technical specifications: Standard pre

-

plumbed cylinders

 

12.3.2

 

Technical specifications: Slimline pre

-

plumbed cylinders

 

Summary of Contents for UK.PPC150SL/R32

Page 1: ...Altherma R32 Monobloc Systems Installation Manual UK PPC150SL R32 UK PPC150 R32 UK PPC180SL R32 UK PPC180 R32 UK PPC210 R32 UK PPC250 R32 UK PPC300 R32 English Installation Manual Domestic hot water...

Page 2: ...that nobody especially children can play with them Possible risk suffocation DANGER RISK OF BURNING Do NOT touch the refrigerant piping water piping or internal parts during and immediate after operat...

Page 3: ...rical DANGER RISK OF ELECTROCUTION Turn OFF all power supply before removing the switch box cover connecting electrical wiring or touching electrical parts Disconnect the power supply for more than 1...

Page 4: ...5 consecutive days after installation Domestic hot water tank Standstills In cases where during longer periods of time there is no consumption of hot water the equipment MUST be flushed with fresh wa...

Page 5: ...mponents The discharge pipe away from the tundish must terminate in a safe visible position without forming any risk to persons in the vicinity WARNING Do NOT install any valves between the domestic h...

Page 6: ...must be installed by a qualified electrician The fuse rating should be sized correctly to suite the heater s duty and isolators must be double pole to BS 3456 Correct cable sizing must be carried out...

Page 7: ...4 5 5 Parts List 4 5 6 Plan View and Dimensions Allow 300mm space in front for servicing immersion heater...

Page 8: ...the factory the pre plumbed cylinder will be supplied with the vessel as a hydraulic separator In order to change the vessel to function only as a volumiser use the following configuration NOTICE On B...

Page 9: ...d protection devices are installed according to this document and have not been bypassed There are NO loose connections or damaged electrical components in the switch box The immersion heater circuit...

Page 10: ...tic cover of the pressure reducing valve 2 Extract the cartridge with the aid of long nosed pliers to grip the heat of the set screw 3 Remove the strainer element 4 Clean the strainer element and cart...

Page 11: ...device such as a timer or connected to a circuit that is regularly turned ON and OFF by the utility 10 3 Solving problems based on symptoms 10 3 1 Symptom No water flow from hot taps Possible causes C...

Page 12: ...the Dixell control panel We recommend the setpoint to be 37o C however it could be changed based on your requirements e g if using low temperature heat emitters If there is no possibility for water ci...

Page 13: ...UK PPC150 300 SL R32 November 2022 Version 2 1 Domestic hot water tank for Daikin Altherma Monobloc R32 12 Technical data 12 1 Components Domestic hot water tank 12 2 Exploded Diagram...

Page 14: ...eight kg 46 56 59 71 86 Material inside cylinder Stainless steel 2304 Water inlet H E mm 28 Piping connections diameter Water outlet H E mm 28 Cold water in mm 22 Hot water out mm 22 Domestic hot wate...

Page 15: ...and applicable for a certain product or domain Service company Qualified company which can perform or coordinate the require service to the product Accessories Labels manuals information sheets and eq...

Page 16: ...Appendix Wiring Connections Factory Fitted Wiring Wiring when using Madoka BRC1HHD Controller...

Page 17: ...Third Party Thermostat 1 Zone Wiring when using Third Party Thermostat 2 Zones Third party controller must be volt free and TPI disabled Cable must be sized for 230V Third party controller must be vol...

Page 18: ...and Service Record Log Book CUSTOMER DETAILS NAME ADDRESS TEL No IMPORTANT 1 Please keep the Log Book in a safe place for future reference 2 This Log Book is to be completed in full by the competent p...

Page 19: ...VALVE AND EXPANSION VALVE FITTED AND DISCHARGE TESTED YES NO IS PRIMARY ENERGY SOURCE CUT OUT FITTED NORMALLY 2 PORT VALVE YES NO WHAT IS THE PRESSURE REDUCING VALVE SETTING IF FITTED YES NO WHERE IS...

Page 20: ...ENTS SIGNATURE SERVICE 2 DATE ENGINEER NAME COMPANY NAME TEL No COMMENTS SIGNATURE SERVICE 3 DATE ENGINEER NAME COMPANY NAME TEL No COMMENTS SIGNATURE SERVICE 4 DATE ENGINEER NAME COMPANY NAME TEL No...

Page 21: ...UK PPC150 300 SL R32 November 2022 Version 2 1 Domestic hot water tank for Daikin Altherma Monobloc R32...

Page 22: ...Daikin UK 1 The Heights Brooklands Weybridge Surrey KT13 0NY...

Reviews: