3. Specifications
Specifications (R22)
FT10LV1L
FT10MV1I
FT10LV1M
FT10MV1J
R09CV1
FT15LV1L
FT15MV1I
FT15LV1M
FT15MV1J
R15CV1
FT20LV1L
FT20MV1I
FT20LV1M
FT20MV1J
R18CV1
FT20LV1L
FT20MV1I
FT20LV1M
FT20MV1J
R20CV1
WIRELESS
WIRED
Btu/hr
10000
13000
W
2931
0.82
3810
0.7
W
980
1220
A
4.38
5.36
V/Ph/Hz
Btu/hr/W
10.20
10.66
l/s / CFM
l/s / CFM
161 / 342
168 / 355
169 / 358
176 / 372
l/s / CFM
133 / 282
141 / 298
l/s / CFM
106 / 225
99 / 209
114 / 242
106 / 225
dBA
39 / 38 / 33 / 27 / 25 41 / 40 / 35 / 29 / 28
mm/in
288 / 11.3
288 / 11.3
mm/in
800 / 31.5
800 / 31.5
mm/in
206 / 8.1
216 / 8.5
mm/in
344 / 13.5
mm/in
874 / 34.4
mm/in
274 / 10.8
kg/lb
-
-
YES
YES
9 / 19.8
mm/in
19 / 0.75
CONTROL
AIR DISCHARGE
220-240 / 1 / 50
AUTO LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)
R22
OUTDOOR CAP. TUBE
INDOOR UNIT
SOUND PRESSURE LEVEL (T/H/M/L/Q)
AIR FLOW
HIGH
TURBO
MEDIUM
UNIT
DIMENSION
HEIGHT
L SERIES
M SERIES
L SERIES
L SERIES
M SERIES
M SERIES
L SERIES
L SERIES
M SERIES
M SERIES
WIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)
UNIT NET WEIGHT
OTHER
FEATURES
PLASMA
NEGATIVE ION
MODEL
OUTDOOR UNIT
LOW
l/s / CFM
QUIET
INDOOR UNIT
NOMINAL CAPACITY
SENSIBLE HEAT FACTOR
NOMINAL TOTAL INPUT POWER
OPERATION
POWER SOURCE
REFRIGERANT TYPE
EER
WIDTH
PACKING
DIMENSION
NOMINAL RUNNING CURRENT
REFRIGERANT CONTROL (EXPANSION DEVICE)
DEPTH
HEIGHT
WIDTH
DEPTH
CONDENSATE DRAIN SIZE
19500
5715
1850
8.12
18000
5275
0.70
0.73
1630
7.16
11.04
280 / 594
251 / 531
224 / 474
199 / 422
180 / 381
44 / 42 / 39 / 36 / 35
310 / 12.2
310 / 12.2
1065 / 41.9
1065 / 41.9
224 / 8.8
233 / 9.2
386 / 15.2
1136 / 44.7
314 / 12.4
14 / 30.8
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER
AS A RESULT OF AMBIENT CONDITION.
10.54
mm/in
mm/in
FAN
TYPE
CROSS FLOW FAN
QUANTITY
1
MATERIAL
GLASS REINFORCED ACRYL STYRENE RESIN
DRIVE
DIRECT
DIAMETER
92 / 3.6
LENGTH
607 / 23.9
FAN MOTOR
TYPE
INDUCTION
QUANTITY
1
INDEX OF PROTECTION (IP)
IP24
POWER SOURCE
RATED INPUT POWER
RATED RUNNING CURRENT
MOTOR OUTPUT
INSULATION GRADE
POLES
SPEED
RPM
V/Ph/Hz
W
A
W
TURBO
HIGH
MEDIUM
LOW
SILENT
CLASS E
220 - 240 / 1 / 50
37
1280
1230
1050
880
830
1320
1270
1100
930
880
40
0.20
18
4
IP44
102 / 4.02
867 / 34.13
61
0.30
26
1130
1050
960
875
800
mm/in
mm/in
mm/in
m²/ft²
COIL
TUBE
MATERIAL
SEAMLESS INNER GROOVE COPPER
DIAMETER
7.00 / 0.276
THICKNESS
0.28 / 0.011
FIN
MATERIAL
ALUMINIUM
THICKNESS
0.11 / 0.0043
FACE AREA
0.18 / 1.94
ROW
2
FIN PER INCH
18
0.24 / 0.00945
0.105 / 0.0041
0.29 / 3.12
pc
LENGTH
mm/in
WIDTH
mm/in
THICKNESS
mm/in
MATERIAL
AIR
QUALITY
FILTER
TYPE
302 / 11.9
280 / 11.0
2.0 / 0.1
CASING
PLASTIC
QUANTITY
SIZE
306 / 12.1
SARANET
2
421 / 16.5
kg/lb
0.60 / 1.3
0.60 / 1.3
REFRIGERANT CHARGE
0.90 / 1.98
0.83 / 1.83