![Daikin TN20PV1M Technical Manual Download Page 22](http://html1.mh-extra.com/html/daikin/tn20pv1m/tn20pv1m_technical-manual_2459154022.webp)
21
TM-FT
-0415-B
Recommended Mounting Plate Retention Spots And Dimensions
Through
the wall
hole
Ø 65mm
Recommended mounting
plate retention spots
(5 spots in all)
Use tape measure as shown.
Position the end of a tape measure
at
166
184
42.2
288
42.2
Drain
hose
position
Gas pipe end
Liquid pipe end
181.7
55.5
54.5
153.8
263
51.9
800
45.9
45.9
All dimensions are in mm
FT10/15LV1L/M & FT10/15MV1I/J
FTN10/15PV1L/M & FTN10/15MV1I9/J9
FT20/25LV1L/M, FT20/25MV1I/J
FTN20/25PV1L/M & FTN20/25MV1I9/J9
All dimensions are in mm
Inside
Outside
Hole with cone drill
Caulking
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Wall embedded pipe
(Field supply)
Ø 65
Mounting plate
Interconnecting
wires
Hang indoor unit’s hook here.
Wire guide
When stripping
the ends of
interconnecting
wires in advance,
bind right ends
of wires with
insulating tape.
Mounting plate
Clip
Mark
(rear side)
Bottom frame
Front grille
End
dipped
into
water
Water
leaking
Water
leaking
Water
leaking
Wrong
Wrong
Wrong
Drain
Water Drainage
Water
retention
Correct
CAUTION
• Do not install the unit at altitude over 2000m
for both indoor and outdoor.
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the installation
plate (Engage the two hooks at the rear top of the indoor unit
with the upper edge of the installation plate). Ensure that the
hooks are properly seated on the installation plate by moving it
to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front grille) to release the claws.
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for smooth drainage. Avoid situations that are
likely to cause water to leak.
Recommended mounting plate
retention spots
(7 spots in all)
190
173
61
310
61
Gas pipe end
Liquid pipe end
48
45
580
1065
219
40
40
91
45
Through the
wall hole
Ø 65mm
Drain hose
position