![Daikin TN20PV1M Technical Manual Download Page 31](http://html1.mh-extra.com/html/daikin/tn20pv1m/tn20pv1m_technical-manual_2459154031.webp)
30
TM-FT
-0415-B
Air Conditioner Unit Operation
In COOL, DRY and FAN mode
When stop
operation
Upper limit 55˚
Lower limit 85˚
Dry Mode
• When the air humidity is high, the unit can operate in dry mode. Press <MODE> button and choose <DRY>.
• If the room temperature is 2°C/3.6°F higher than the set temperature, the air conditioner will operate
under cooling mode until it reaches within the 2°C/3.6°F range of difference compared to the set
temperature before it converts to dry mode.
• If the room temperature is within the 2°C/3.6°F range of difference compared to the set temperature,
it will directly operate under dry mode.
• The unit will operate at LOW speed under dry mode.
Air Flow Control
• For more effective air circulation, you can manually adjust the air discharge grille to the left or right.
• During cool mode operation and dry mode operation, do not direct the air discharge louver down-
wards for too long. If operating continues in this way, condensation may occur on the louver, thus
resulting indrippings.
Frost Prevention
• When the air filter is dirty, the evaporating temperature will decrease and eventually cause frosting.
• If the evaporating temperature reaches -1°C/33.8°F, the unit will trip.
Fan Speed And Rated Cooling Capacity
• The rated cooling capacity is provided at the high fan speed.
• The cooling capacity is lower when the unit is operating at MEDIUM and LOW fan speed.
Notes On Flaps And Louvers Angles
• When “SWING button” is selected, the flaps swinging range depends on the operation mode.
(See the figure.)
ATTENTION
• Always use a remote controller to adjust the flaps angle. If you attempt to move it forcibly with hand
when it is swinging, the mechanism may be broken.
• Be careful when adjusting the louvers. Inside the air outlet, a fan is rotating at a high speed.
Auto Random Re-start Function
If there is a power cut when the unit is operating, it will automatically resume the same operating mode
when the power is restored.